Preferred Language
Articles
/
bsj-1001
Cultivation of Entamoeba histolytica in vitro and diagnose the bacterial growths in culture media
...Show More Authors

The parasite was isolated from a stool sample, cultivated and maintained in vitro using Locke-egg medium (LEM) and Liver infusion agar medium (LIAM) . The culture was maintained for up to 21 months, and the best time to maintain the parasite was every 48 hours, although the growth in the culture media continued for 13 days without a maintenance. Additionally, no cyst formation was observed during cultivation of parasite in the two culture media. Although, was observe young cyst formed in LEM media were deletion of maintained. The diagnosis of bacteria growth in the culture media, bacterial content (Escherichia coli) was an dominance and essential requirement for a successful cultivation of Entamoeba histolytica in the two culture media.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Buckling Analysis Of Damaged Composite Plates Under Uniform Or Non-Uniform Compressive Load
...Show More Authors

The present study focused mainly on the buckling behavior of composite laminated plates subjected to mechanical loads. Mechanical loads are analyzed by experimental analysis, analytical analysis (for laminates without cutouts) and numerical analysis by finite element method (for laminates with and without cutouts) for different type of loads which could be uniform or non-uniform, uniaxial or biaxial. In addition to many design parameters of the laminates such as aspect ratio, thickness ratio, and lamination angle or the parameters of the cutout such as shape, size, position, direction, and radii rounding) which are changed to studytheir effects on the buckling characteristics with various boundary conditions. Levy method of classical lam

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Aug 01 2016
Journal Name
Journal Of Engineering
Behavior of Reinforced Concrete Deep Beams Strengthened with Carbon Fiber Reinforced Polymer Strips
...Show More Authors

This research is concerned to investigate the behavior of reinforced concrete (RC) deep beams strengthened with carbon fiber reinforced polymer (CFRP) strips. The experimental part of this research is carried out by testing seven RC deep beams having the same dimensions and steel reinforcement which have been divided into two groups according to the strengthening schemes. Group one was consisted of three deep beams strengthened with vertical U-wrapped CFRP strips. While, Group two was consisted of three deep beams strengthened with inclined CFRP strips oriented by 45o with the longitudinal axis of the beam. The remaining beam is kept unstrengthening as a reference beam. For each group, the variable considered

... Show More
View Publication Preview PDF
Publication Date
Mon Aug 01 2011
Journal Name
Journal Of Engineering
INVESTIGATION OF TWISTED TAPE TURBULATOR FOR FIRE TUBE BOILER Part I. Heat Transfer
...Show More Authors

The present work presents a new experimental study of the enhancement of turbulent
convection heat transfer inside tubes for combined thermal and hydrodynamic entry length of one
popular “turbulator” (twisted tape with width slightly less than internal tube diameter) inserted for
fire tube boilers. Cylindrical combustion chamber was used to burn (1.6 to 7kg/h) fuel oil #2 to
deliver hot gases with ranges of Reynolds number (10500 to 21700), and (11400 to 24150) for both
empty and inserted tube respectively.A uniform wall temperature technique was used by keeping
approximately constant water temperature difference (25ºC) between inlet and exit cooling water in
parallel flow shell and tube heat exchanger. The test

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Journal Of Engineering
Reinforcement of Asphalt Concrete by Polyester Fibers to Improve Flexural Bending Fatigue Resistance
...Show More Authors

Reinforcing asphalt concrete with polyester fibers considered as an active remedy to alleviate the harmful impact of fatigue deterioration. This study covers the investigation of utilizing two shapes of fibers size, 6.35 mm by 3.00 mm and 12.70 mm by 3.00 mm with mutual concentrations equal to 0.25 %, 0.50 % and 0.75 % by weight of mixture. Composition of asphalt mixture consists of different optimum (40-50) asphalt cement content, 12.50 mm nominal aggregate maximum size with limestone dust as a filler. Following the traditional asphalt cement and aggregate tests, three essential test were carried out on mixtures, namely: Marshall test (105 cylindrical specimens), indirect tensile strength test (21 cylindrical specimens)

... Show More
View Publication
Publication Date
Sun Jan 14 2018
Journal Name
Journal Of Engineering
Optimum Design of Power System Stabilizer based on Improved Ant Colony Optimization Algorithm
...Show More Authors

This paper presents an improved technique on Ant Colony Optimization (ACO) algorithm. The procedure is applied on Single Machine with Infinite Bus (SMIB) system with power system stabilizer (PSS) at three different loading regimes. The simulations are made by using MATLAB software. The results show that by using Improved Ant Colony Optimization (IACO) the system will give better performance with less number of iterations as it compared with a previous modification on ACO. In addition, the probability of selecting the arc depends on the best ant performance and the evaporation rate.

 

View Publication Preview PDF
Publication Date
Mon May 01 2023
Journal Name
Journal Of Engineering
Experimental Evaluation of PV Panel Efficiency Using Evaporative Cooling Integrated with Water Spraying
...Show More Authors

In this work, an inventive photovoltaic evaporative cooling (PV/EC) hybrid system was constructed and experimentally investigated. The PV/EC hybrid system has the prosperous advantage of producing electrical energy and cooling the PV panel besides providing cooled-humid air. Two cooling techniques were utilized: backside evaporative cooling (case #1) and combined backside evaporative cooling with a front-side water spray technique (case #2). The water spraying on the front side of the PV panel is intermittent to minimize water and power consumption depending on the PV panel temperature. In addition, two pad thicknesses of 5 cm and 10 cm were investigated at three different water flow rates of 1, 2, and 3 lpm. In Case #1,

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Thu Mar 01 2018
Journal Name
Materials Today Communications
Improved mechanical properties of sol-gel derived ITO thin films via Ag doping
...Show More Authors

View Publication
Scopus (22)
Crossref (26)
Scopus Clarivate Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Optical Fiber Technology
Highly sensitive measurement of surrounding refractive index using tapered trench–assisted multicore fiber
...Show More Authors

View Publication
Scopus (18)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Sun Dec 29 2019
Journal Name
Iraqi Journal Of Science
Antibacterial activity of Some mouthwash Solutions against Staphylococcus lentus Isolated from Mouth Infections
...Show More Authors

A total of nine swab samples were collected from inflamed teeth and gingiva of human’soral cavity from a dentist clinic in Baghdad. All specimens were cultured in Mitis Salivarius agar medium and the isolated bacterial pure colonies werethen identified by using VITEK2. Three samples were diagnosed and identified as Staphylococcus lentus. One of the three isolates which showed a distinctive heavy growth on the media was selected for further analysis in this study. Paper disk diffusion method was used to detect the antibacterial activityof three of mouthwash solutions (Zak, Colgate and Listerine). The results showed that “Colgate” was the most active solution with antibacterial activity compared with the other two s

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Finite element analysis of seepage for Kongele earth dam Using Geo- Studio software
...Show More Authors
Abstract<p>Seepage occurs under or inside structures or in the place, where they come into contact with the sides under the influence of pressure caused by the difference in water level in the structure U / S and D / S. This paper is designed to model seepage analysis for Kongele (an earth dam) due to its importance in providing water for agricultural projects and supporting Tourism sector. For this purpose, analysis was carried out to study seepage through the dam under various conditions. Using the finite element method by computer program (Geo-Studio) the dam was analysed in its actual design using the SEEP / W 2018 program. Several analyses were performed to study the seepage across Kongele </p> ... Show More
View Publication
Scopus (8)
Crossref (7)
Scopus Crossref