Preferred Language
Articles
/
bijps-762
X-Ray Fluorescence Determination of Trace Elements in Vitamin-Mineral Complexes and Medicinal Herbs Using Chemically Modified Polyurethane Foam Sorbents
...Show More Authors

In this paper we proposed the method of X-ray fluorescence (XRF) determination of some essential trace elements in medicinal herbs and vitamin-mineral complexes at the level of 100-101 mg/ml. To increase sensitivity and selectivity of the determination we simple and effective approach based on the extraction of metal ions from aqueous solutions with chemically modified polyurethane foam sorbents followed by direct XRF analysis. The conditions of sorption preconcentration of Co(II), Ni(II) and Zn(II) ions with modified sorbents were optimized. The proposed approach is used for the determination of trace elements in several kinds of medicinal herbs (coltsfoot leaves, nettle leaves and yarrow herb) and vitamin-mineral complexes («Alfavit», «Vitrum» and «Multi-tabs»).

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 01 2015
Journal Name
Journal Of Engineering
Modified Grid Clustering Technique to Predict Heat Transfer Coefficient in a Duct of Arbitrary Cross Section Area
...Show More Authors

A simple straightforward mathematical method has been developed to cluster grid nodes on a boundary segment of an arbitrary geometry that can be fitted by a relevant polynomial. The method of solution is accomplished in two steps. At the first step, the length of the boundary segment is evaluated by using the mean value theorem, then grids are clustered as desired, using relevant linear clustering functions. At the second step, as the coordinates cell nodes have been computed and the incremental distance between each two nodes has been evaluated, the original coordinate of each node is then computed utilizing the same fitted polynomial with the mean value theorem but reversibly.

The method is utilized to predict

... Show More
View Publication Preview PDF
Publication Date
Fri Oct 04 2024
Journal Name
Analytical And Bioanalytical Chemistry Research
Optimization and Validation of a GC-FID/QuEChERS Method for Quantitative Determination of Spiromesifen Residues in Tomato Fruits, Leaves and Soil Matrices
...Show More Authors

Pesticides serve a crucial function in contemporary farming practices, safeguarding agricultural crops against pest infestations and boosting production outputs. However, indiscriminate use has caused environmental and human health damage. This study aimed to develop and validate a gas chromatography-flame ionization detection (GC-FID) methodology for the direct and routine analysis of spiromesifen residues in soil, leaves, and tomato fruits. The proposed method prioritizes simplicity by avoiding derivatization steps, offering advantages over existing approaches that utilize lengthy multi-step extraction or derivatization prior to GC analysis. A key novelty of this work is the development of a QuEChERS extraction coupled directly to GC-FID

... Show More
Scopus (3)
Scopus
Publication Date
Mon Apr 13 2026
Journal Name
Oxidation Communications
DEVELOPMENT AND VALIDATION OF HIGHPERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR THE SIMULTANEOUS DETERMINATION OF ANTIBIOTICS IN THEIR PURE FORM AND PHARMACEUTICAL FORMS
...Show More Authors

Beta-lactam medications are among the commonly used antibiotics that share the presence of a beta-lactam ring in their chemical formation. A modern, rapid, highperformance liquid chromatography technique was advanced and validated according to FDA and EMA rules for the concurrent determination of medications in their pharmaceutical and pure forms This study deals with the determination of beta-lactam drugs )Amoxicillin, Ampicillin Cephalexin, Cefotaxime, Cefoxitin, Cefamandole, Cephalothin, Piperacillin, Penicillin, Oxacillin, Cloxacillin Nafcillin, Carbenicillin, Mezlocillin and Dicloxacillin) which is a RP-HPLC technique with an UV detector using a column NEUCLEODUR C-18 (4.0 mm × 100 mm, 5µm particle size), The heat of the chr

... Show More
Publication Date
Mon Dec 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Enhanced conversion of Glycerol to Glycerol carbonate on modified Bio-Char from reed plant: Enhanced conversion of Glycerol to Glycerol carbonate on modified Bio-Char from reed plant
...Show More Authors

The surplus glycerol produced from biodiesel production process as a by-product with high quantity can be considered as a good source to prepare glycerol carbonate (GC) whereas with each 1000 kg from biodiesel obtains 100 kg from glycerol. Glycerol converted to glycerol carbonate over bio-char as a catalyst prepared by slow pyrolysis process under various temperatures from 400 ᴼC to 800 ᴼC. The char prepared at 700 ᴼC considered as a best one between the others which was manufactured to activate the transesterification reaction. GC have large scale of uses such as liquid membrane in gas separation, surfactants ,detergents , blowing agent , in plastics industry, in  Pharmaceutical industry and electrolytes in lithium batteries.

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Siriraj Medical Journal
The Potential of Vitamin-D-Binding Protein as a Urinary Biomarker to Distinguish Steroid-Resistant from Steroid-Sensitive Idiopathic Nephrotic Syndrome in Iraqi Children
...Show More Authors

Objective: To determine the ability of uVDBP to discern SRNS from steroid-sensitive nephrotic syndrome (SSNS) in Iraqi children. Materials and Methods: This cross-sectional study enrolled children with SRNS (n=31) and SSNS (n=32) from the pediatric nephrology clinic of Babylon Hospital for Maternity and Pediatrics over three months. Patients' characteristics in terms of demographics, clinical data, and urinary investigations were collected. Quantitative analysis of uVDBP levels was undertaken via a commercially available ELISA kit. Results: The median uVDBP values were significantly higher (p-value<0.001) in the SRNS group (median=10.26, IQR=5.91 μg/mL) than in the SSNS group (median=0.953, IQR=4.12 μg/mL). A negative correlati

... Show More
View Publication
Scopus (7)
Crossref (4)
Scopus Crossref
Publication Date
Sat Aug 01 2020
Journal Name
Jordan Journal Of Physics
Theoretical Simulation of Backscattering Electron Coefficient for SixGe1-x/Si Heterostructure as a Function of Primary Electron Beam Energy and Ge Concentration
...Show More Authors

Abstract: This study aims to investigate the backscattering electron coefficient for SixGe1-x/Si heterostructure sample as a function of primary electron beam energy (0.25-20 keV) and Ge concentration in the alloy. The results obtained have several characteristics that are as follows: the first one is that the intensity of the backscattered signal above the alloy is mainly related to the average atomic number of the SixGe1-x alloy. The second feature is that the backscattering electron coefficient line scan shows a constant value above each layer at low primary electron energies below 5 keV. However, at 5 keV and above, a peak and a dip appeared on the line scan above Si-Ge alloy and Si, respectively, close to the interfacing line

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Wed Nov 14 2018
Journal Name
Journal Of Engineering And Applied Sciences
DEMONSTRATE OF MAGNETIC FIELD EFFECT ON THE CAPABILITY OF ADSORPTION PROCESS IN THE REMOVAL OF AZO DYE FROM THE AQUEOUS SOLUTIONS ON CALCINED IRAQI BENTONITE CLAY MINERAL VIA COLUM
...Show More Authors

Publication Date
Tue Dec 30 2025
Journal Name
Alnahrain Journal Of Legal Scienci
Elements and Conditions of Personal Civil Liability (Based on Fault) for the Government for Damages Caused by Demonstrations: A Comparative Study
...Show More Authors

This study examines the position of comparative legislation (French legislation, English legislation, and Egyptian legislation) in addressing the regulation of personal civil liability (based on fault) for the government. About the damages caused by demonstrations in terms of their legal nature, their legal basis, and the pillars and conditions of that responsibility. Then, we explain the position of the Iraqi legislator and compare it with what is the case in the legislation mentioned above

Preview PDF
Publication Date
Thu Nov 22 2018
Journal Name
Al-khwarizmi Engineering Journal
Experimental and Finite Elements Analysis Study of Warming Effect on Deboned Force for Embedded NiTinol Wire into Linear Low Density Polyethylene
...Show More Authors

This study presents the debonding propagation in single NiTi wire shape memory alloy into linear low-density polyethylene matrix composite the study of using the pull-out test. The aim of this study is to investigate the pull-out tests to check the interfacial strength of the polymer composite in two cases, with activation NiTinol wire and without activation. In this study, shape memory alloy NiTinol wire 2 mm diameter and linear fully annealed straight shape were used. The study involved experimental and finite element analysis and eventually comparison between them. This pull-out test is considered a substantial test because its results have a relation with behavior of smart composite materials. The pull-out test was carried out by a u

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Determination of Water-Soluble Vitamins in Iraqi Honey Bee and Compare with Others Types by High –Performance Liquid Chromatography
...Show More Authors

High-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was

... Show More
View Publication Preview PDF
Crossref (4)
Crossref