Preferred Language
Articles
/
bijps-559
A Study on the Stability of Different Frusemide Liquid Dosage Formulas: Oral Solution, Syrup, Elixir, Suspension and Emulsion
...Show More Authors

The present study aim at preparing frusemide in liquid form suitable for oral use. This is achieved through preparing different liquid forms of frusemide. The frusemide liquid is prepared in the following forms: oral solution, syrup and elixir with intensity of 1, 0.4 and 0.8% weight /volume respectively and in combination with potassium carbonate, polysorbate 80, alcohol and phosphate buffer solution of pH8 to dissolve the frusemide in the above mentioned forms. The different forms of the prepared medicine have been stored in glass bottles that can provide protection against light and at 40, 50, 600C for four months. Besides the pH has been checked to decide the period of validity. The results show that the expiration date of frusemide have lasted for 1.8, 1.07 and 1.22 years respectively for the oral solution, the syrup and the elixir. The suspensions of frusemide are formulated in combination with the following: polyvinyl pyrolidine, xanthan gum, the combination of (xanthan gum and sodium carboxymethyl cellulose), the combination of (xanthan: methyl cellulose) and chitosan.  The formulas which give suitable release of the drug are chosen for assessment according to the following considerations: The rat of sedimentation and apparent zero order degradation constant at 250C. In conclusion, it is found the best formula is that which includes poly vinylpyrolidine, tween20, glycerol, sorbitol, cocoa syrup and parabens at pH7. the fluidity of this chosen formula is psendoplastic type and its validity has lasted for about three years. The emulsion of frusemide is also prepared extemporaneously by using the commercial frusemide tablets in combination with acacia and olive oil. This should be consumed within 45 days of the date of production.

Key word: frusemide, elixir, suspension, emulsion.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Dec 07 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Novel Combination for Self-Nanoemulsifying Drug Delivery System of Candesartan Cilexetil
...Show More Authors

Solubility problem of many of effective pharmaceutical molecules are still one of the major obstacle in theformulation of such molecules. Candesartan cilexetil (CC) is angiotensin II receptor antagonist with very low water solubility and this result in low and variable bioavailability. Self- emulsifying drug delivery system (SEDDS) showed promising result in overcoming solubility problem of many drug molecules. CC was prepared as SEDDS by using novel combination of two surfactants (tween 80 and cremophore EL) and tetraglycol as cosurfactant, in addition to the use of triacetin as oil. Different tests were performed in order to confirm the stability of the final product which includes thermodynamic study, determination of self-emulsificat

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (1)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Methods And Objects Of Chemical Analysis
Spectrophotometric Analysis of Quaternary Drug Mixtures using Artificial Neural network model
...Show More Authors

A Novel artificial neural network (ANN) model was constructed for calibration of a multivariate model for simultaneously quantitative analysis of the quaternary mixture composed of carbamazepine, carvedilol, diazepam, and furosemide. An eighty-four mixing formula where prepared and analyzed spectrophotometrically. Each analyte was formulated in six samples at different concentrations thus twentyfour samples for the four analytes were tested. A neural network of 10 hidden neurons was capable to fit data 100%. The suggested model can be applied for the quantitative chemical analysis for the proposed quaternary mixture.

View Publication
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Iaes International Journal Of Artificial Intelligence
Reduced hardware requirements of deep neural network for breast cancer diagnosis
...Show More Authors

Identifying breast cancer utilizing artificial intelligence technologies is valuable and has a great influence on the early detection of diseases. It also can save humanity by giving them a better chance to be treated in the earlier stages of cancer. During the last decade, deep neural networks (DNN) and machine learning (ML) systems have been widely used by almost every segment in medical centers due to their accurate identification and recognition of diseases, especially when trained using many datasets/samples. in this paper, a proposed two hidden layers DNN with a reduction in the number of additions and multiplications in each neuron. The number of bits and binary points of inputs and weights can be changed using the mask configuration

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Society Of Petroleum Engineering
Stress-dependent petrophysical properties of high heterogeneous carbonate tight oil reservoirs
...Show More Authors

Scopus (9)
Scopus
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Ecological Engineering
Biosynthetic of Titanium Dioxide Nanoparticles Using Zizyphus Spina-Christi Leaves Extract
...Show More Authors

View Publication
Scopus (12)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Implementation of hierarchically porous zeolite-polymer membrane for Chromium ions removal
...Show More Authors
Abstract<p>This work deals with the preparation of a zeolite/polymer flat sheet membrane with hierarchical porosity and ion-exchange properties. The performance of the prepared membrane was examined by the removal of chromium ions from simulated wastewater. A NaY zeolite (crystal size of 745.8 nm) was prepared by conventional hydrothermal treatment and fabricated with polyethersulfone (15% PES) in dimethylformamide (DMF) to obtain an ion-exchange ultrafiltration membrane. The permeate flux was enhanced by increasing the zeolite content within the membrane texture indicating increasing the hydrophilicity of the prepared membranes and constructing a hierarchically porous system. A membrane contain</p> ... Show More
View Publication
Scopus (32)
Crossref (19)
Scopus Crossref
Publication Date
Wed Jul 01 2020
Journal Name
Ieee Transactions On Industrial Electronics
Finite-Time Continuous Terminal Sliding Mode Control of Servo Motor Systems
...Show More Authors

In this article, a continuous terminal sliding mode control algorithm is proposed for servo motor systems. A novel full-order terminal sliding mode surface is proposed based on the bilimit homogeneous property, such that the sliding motion is finite-time stable independent of the system’s initial condition. A new continuous terminal sliding mode control algorithm is proposed to guarantee that the system states reach the sliding surface in finitetime. Not only the robustness is guaranteed by the proposed controller but also the continuity makes the control algorithm more suitable for the servo mechanical systems. Finally, a numerical example is presented to depict the advantages of the proposed control algorithm. An application in the rota

... Show More
View Publication
Scopus (223)
Crossref (198)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Acta Polytechnica
COMPLEXITY REDUCTION OF CYCLOSTATIONARY SENSING TECHNIQUE USING IMPROVED HYBRID SENSING METHOD
...Show More Authors

In cognitive radio system, the spectrum sensing has a major challenge in needing a sensing method, which has a high detection capability with reduced complexity. In this paper, a low-cost hybrid spectrum sensing method with an optimized detection performance based on energy and cyclostationary detectors is proposed. The method is designed such that at high signal-to-noise ratio SNR values, energy detector is used alone to perform the detection. At low SNR values, cyclostationary detector with reduced complexity may be employed to support the accurate detection. The complexity reduction is done in two ways: through reducing the number of sensing samples used in the autocorrelation process in the time domain and through using the Slid

... Show More
View Publication
Scopus (8)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Fri May 15 2020
Journal Name
International Journal Of Research In Pharmaceutical Sciences
Urodynamic findings of bladder dysfunction in patients with Type 2 DM
...Show More Authors

Bladder dysfunction is one of the most common complications of diabetes, even exceeding nephropathy or peripheral neuropathy. Diabetic cystopathyaffects patients in both sexes, and its prevalence increases over time with diabetes; our concern is to evaluate the urodynamic findings of bladder dysfunction in diabetic patients.A cross sectional study conducted at Ghazi Al-Hariri Surgical specialized hospital during the period from the firsts of January 2018 to the end of Mar 2019, in which 118 diabetic patients (71 female and 47 male) with lower urinary tract symptoms were enrolled in the current study. The mean age (62±13) years old, 37.3% of patients presented with urgency as the main type of dysfunction. Diabetic cystopathy were fo

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Mon Mar 02 2020
Journal Name
Iraqi Geological Journal
RESERVOIR MODELING OF MISHRIF FORMATION IN MAJNOON OIL FIELD, SOUTHERN IRAQ
...Show More Authors

The Middle Cenomanian-Early Turonian Mishrif Formation includes important carbonate reservoirs in Iraq and some other surrounding countries due to their high reservoir quality and wide geological extension. The 2D models of this study for facies, effective porosity and water saturation indicate the vertical and lateral heterogeneity of the Mishrif Formation reservoir properties in the Majnoon oil field. Construction of 2D reservoir model of the Mishrif Formation to explain the distribution of facies and petrophysical properties (effective porosity and water saturation) by using RockWorks software. The increase of effective porosity is attributed to the presence of shoal facies.The high water saturation is attributed to the existence of rest

... Show More
View Publication
Scopus (22)
Crossref (7)
Scopus Crossref