Preferred Language
Articles
/
bijps-1776
Detection of Epicatechin in Camellia sinensis Leaves by Thin Layer Chromatography and High Performance Liquid Chromatography Techniques
...Show More Authors

    The current study performed in order to detect and quantify epicatechin in two tea samples of Camellia sinensis (black and green tea) by thin layer chromatography (TLC) and high performance liquid chromatography (HPLC). Extraction of epicatechin from black and green tea was done by using two different methods: maceration (cold extraction method) and decoction (hot extraction method) involved using three different solvents which are  absolute ethanol, 50% aqueous ethanol and water  for both extraction methods using room temperature and direct heat respectively. Crude extracts of two tea samples that obtained from two methods were fractionated by using two solvents with different polarity (chloroform and ethyl acetate). Qualitative and quantitative determinations of epicatechin in tea samples were investigated. Epicatechin identification was made by utilizing preliminary chemical tests and TLC. This identification was also boosted by HPLC and the quantity of epicatechin was determined in all ethyl acetate fractions of two tea samples. This research revealed the existence of epicatechin in black and green tea according to TLC and HPLC. Aqueous ethanol 50% was the best solvent for extraction of epicatechin from leaves of tea. Quantitative estimation of epicatechin by HPLC revealed that ethyl acetate fraction of DGTAE contains the higher concentration of epicatechin than other analyzed fractions. Conclusion, tea is an excellent source of catechins particularly epicatechin that possessed various pharmacological effects.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Dec 01 2010
Journal Name
Iraqi Journal Of Physics
An Improved Method for the Determination of Airplane Radial Velocity Using Doppler Shift
...Show More Authors

In this research velocity of moving airplane from its recorded digital sound is introduced. The data of sound file is sliced into several frames using overlapping partitions. Then the array of each frame is transformed from time domain to frequency domain using Fourier Transform (FT). To determine the characteristic frequency of the sound, a moving window mechanics is used, the size of that window is made linearly proportional with the value of the tracked frequency. This proportionality is due to the existing linear relationship between the frequency and its Doppler shift. An algorithm was introduced to select the characteristic frequencies, this algorithm allocates the frequencies which satisfy the Doppler relation, beside that the tra

... Show More
View Publication Preview PDF
Publication Date
Wed May 01 2019
Journal Name
Journal Of Engineering
Determination of the Optimum formula for Composite Motor Gasoline Octane Number Blending Enhancer
...Show More Authors

To decrease the dependency of producing high octane number gasoline on the catalytic processes in petroleum refineries and to increase the gasoline pool, the effect of adding a suggested formula of composite blending octane number enhancer to motor gasoline composed of a mixture of oxygenated materials (ethanol and ether) and aromatic materials (toluene and xylene) was investigated by design of experiments made by Mini Tab 15 statistical software. The original gasoline before addition of the octane number blending enhancer has a value of (79) research octane number (RON). The design of experiments which study the optimum volumetric percentages of the four variables, ethanol, toluene, and ether and xylene materials leads

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Journal Of Engineering
Removal of Cadmium from Simulated Wastewaters Using a Fixed Bed Bio-electrochemical Reactor
...Show More Authors

In this research, the removal of cadmium (Cd) from simulated wastewater was investigated by using a fixed bed bio-electrochemical reactor. The effects of the main controlling factors on the performance of the removal process such as applied cell voltage, initial Cd concentration, pH of the catholyte, and the mesh number of the cathode were investigated. The results showed that the applied cell voltage had the main impact on the removal efficiency of cadmium where increasing the applied voltage led to higher removal efficiency. Meanwhile increasing the applied voltage was found to be given lower current efficiency and higher energy consumption.  No significant effect of initial Cd concentration on the removal efficie

... Show More
View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Mon Mar 07 2022
Journal Name
Journal Of Educational And Psychological Researches
The effect of using cognitive strategies on mathematical competence among Fourth Scientific students
...Show More Authors

The research aims to find out the impact of cognitive strategies in the mathematical competence of the students of the fourth scientific in the preparatory mahmoudiyah in the Directorate General of The Education of Karkh 2. A post-test of the mathematical competence prepared by (Jassim, 2018) was applied to the sample of (65) students, distributed into two groups of (33) students as experimental group and (32) students as a control group. The results found there are significant differences between the experimental group and the control group in testing the mathematical competence of students for the experimental group.

View Publication Preview PDF
Publication Date
Fri Mar 31 2017
Journal Name
Al-khwarizmi Engineering Journal
Corrosion Behavior of Nanocomposite Al-9 wt% Si Alloy Reinforced with Carbon Nanotubes
...Show More Authors

An effort is made to study the effect of composite nanocoating using aluminum-9%wt silicon alloys reinforced with different percentage (0.5,1,2,4)wt.% of carbon nanotubes (CNTs) using  plasma spraying. The effect of this composite on corrosion behavior for AA6061-T6 by extrapolation Tafel test in sea water 3.5wt% NaCl was invested. Many specimens where prepared from AA6061-T6 by the dimension (15x15x3)mm as this first set up and other steps include coating process, X-ray diffraction and SEM examination .The results show the CNTs increase the corrosion rate of the nanocomposite coatings with increasing the weight percentage of CNTs within the Al-Si matrix. Al-9wt%Si coating layer itself has less corrosion rate if compared with both n

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Jun 05 2023
Journal Name
Journal Of Engineering
Effect of Velocity on Dissolved Oxygen Cathodic Polarization using a Rotating Cylinder Electrode
...Show More Authors

The aim of the present work to study the effect of changing velocity (Reynold's number) on oxygen cathodic polarization using brass rotating cylinder electrode in 0.1, 0.3 and 0.5N NaCl solutions (PH = 7) at temperatures 40, 50 and 600 C. Cathodic polarization experiments were conducted as a function of electrode rotational speed and concentration.

View Publication Preview PDF
Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Jpras Open
The utility of a novel vacuum-assisted foreign body extraction technique from wounds
...Show More Authors

Retained soft tissue foreign bodies following injuries are frequently seen in the Emergency and Plastic Surgery practice. The patients with such presentations require a watchful and detailed clinical as- sessment to overcome the anticipant possibility of missing them. However, the diagnosis based on the clinical evaluation is usually challenging and needs to be supported by imaging modalities that are suboptimal and may fail in identifying some types of foreign bodies. Owing to that, serious complications such as chronic pain, infection, and delayed wound healing can be faced that necessitate a prompt intervention to halt those detrimental consequences. The classical method of removal is a surgical exploration which is not free of risks.

... Show More
Publication Date
Mon Apr 15 2019
Journal Name
Proceedings Of The International Conference On Information And Communication Technology
Optimal control of compliant planar robot for safe impact using steepest descent technique
...Show More Authors

View Publication
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri Jun 19 2026
Journal Name
Journal Of Physical Education
Standard Levels of Modern Administration for the Iraqi Central Olympic Committee's Olympic Federations
...Show More Authors

The problem of the research lies in the lack of standard levels for modern administration as a guide for evaluating weaknesses and strengths as well as finding solutions. The aim of the research lies in identifying standard levels for modern administration in Iraqi central Olympic committee and international federations. The subjects were (24) Olympic committee' federations. All procedures were standardized to fit our modern administration work. The data was collected and treated using proper statistical operations. The researcher concluded standard levels for modern administration in international federation of the Iraqi Olympic committee, in addition to that he concluded that most administrations levels ranged within four levels (good, fa

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Salivary Secretory Immunoglobulin A (sIg A) Level during Fixed Orthodontic Treatment
...Show More Authors

Background: The immune system of the oral cavity suffers alterations due to fixed orthodontic treatment which act as potent stimulus for oral secretory immunity. The aims of this study are to estimate the effect of fixed orthodontic appliance on the level of salivary sIgA at different time intervals, and to verify the gender difference. Materials and method: The patient's history, clinical examination, and fixed orthodontic appliances were placed for 30 Iraqi orthodontic adult patients had class II division 1 and/ or class I malocclusion (15 males and 15 females) aged 18-25 years old. The unstimulated whole saliva was collected from each sample immediately before wearing fixed appliance (control group T0 as base line), and after 2 weeks (T1

... Show More
View Publication Preview PDF
Crossref