Aceclofenac (AC) is an orally active phenyl acetic acid derivative, non-steroidal anti-inflammatory drug with exceptional anti-inflammatory, analgesic and antipyretic properties. It has low aqueous solubility, leading to slow dissolution, low permeability and inadequate bioavailability. The aim of the current study was to prepare and characterize AC-NS-based gel to enhance the dissolution rate and then percutaneous permeability. NS.s were prepared using solvent/antisovent precipitation method at different drug to polymer ratios (1:1, 1:2, and 1:3) using different polymers such as poly vinyl pyrrolidone (PVP-K25), hydroxy propyl methyl cellulose (HPMC-E5) and poloxamer® (388) as stabilizers alone and in combinations of two polymers (1:2 and 1:4 Drug: polymer ratio). Fifteen formulas of AC-NS.s were prepared and characterized for production yield, loading efficiency, particle size, polydispersity index and physical stability. The best formulas of NS were then lyophilized to be characterized by FTIR, DSC, P-XRD and SEM. After that, the best prepared formula of AC-NS regarding the involved characterization methods was incorporated in gel dosage forms using carbopol®940. From this study, we conclude that the dissolution rate and permeability of AC were improved when the particle size was reduced to Nano-scale as compared with pure drug.
those affected by technological development risks within the scope of medical works. The unprecedented technological development the world witnesses nowadays has been providing brilliant medical service to the human being including examination, diagnosis and the treatment or follow up. However, such works hide behind potential risks threatening people's lives and such risks my be discovered within the limits of now – how and technical knowledge prevailing the time of rendering the medical service. Also this the question is raised on how to keep up between the safety of the patients and such risks are being unknown by the provider and questioning them contradicts the justices. subsequently, can the patients (affected) acquire the compensat
... Show MoreCongenital adrenal hyperplasia is a group of autosomal recessive disorders. The most frequent one is 21-hydroxylase deficiency. Analyzing
Abstract
Semiconductor-based gas sensors were prepared, that use n-type tin oxide (SnO2) and tin oxide: zinc oxide composite (SnO2)1-x(ZnO)x at different x ratios using pulse laser deposition at room temperature. The prepared thin films were examined to reach the optimum conditions for gas sensing applications, namely X-ray diffraction, Hall effect measurements, and direct current conductivity. It was found that the optimum crystallinity and maximum electron density, corresponding to the minimum charge carrier mobility, appeared at 10% ZnO ratio. This ratio appeared has the optimum NO2 gas sensitivity for 5% gas concentration at 300 °C working temperat
... Show MoreThis work presents external morphological study of the leafhopper Empoasca decedens
Paoli, 1932 particularly male genitalia, which were dissected and illustrated.
The genus Empoasca Walsh (Typhlocybinae: Empoascini) contains small, slender, fragile
and generally green leafhoppers. The overall length ranges from 3-3.5 mm. Members of this
genus are charachterized by their uniformly green color, inner and outer apical cells of
forewing not attaining wing apex, second and third apical cells are sessile or triangular or
even short stalked, submarginal vein of hindwing extends around wing apex and turned
beneath costal margin, apical thirds of tibiae and tarsal segments including claws are
prominently green while other
Variations in perspective, illumination, motion blur, and weatherworn degeneration of signs may all be essential factors in road-sign identification. The current research purpose is to evaluate the effectiveness of the image processing technique in detecting road signs as well as to find the appropriate threshold value range for doing so. The efficiency of the cascade object detector in detecting road signs was tested under variations of speed and threshold values. The suggested system involved using video data to calculate the number of frames per second and creating an output file that contains the specified targets with their labels to use later in the final process (i.e., training stage). In the current research, two videos
... Show MoreA Wearable Robotic Knee (WRK) is a mobile device designed to assist disabled individuals in moving freely in undefined environments without external support. An advanced controller is required to track the output trajectory of a WRK device in order to resolve uncertainties that are caused by modeling errors and external disturbances. During the performance of a task, disturbances are caused by changes in the external load and dynamic work conditions, such as by holding weights while performing the task. The aim of this study is to address these issues and enhance the performance of the output trajectory tracking goal using an adaptive robust controller based on the Radial Basis Function (RBF) Neural Network (NN) system and Hamilton
... Show MoreIn low-latitude areas less than 10° in latitude angle, the solar radiation that goes into the solar still increases as the cover slope approaches the latitude angle. However, the amount of water that is condensed and then falls toward the solar-still basin is also increased in this case. Consequently, the solar yield still is significantly decreased, and the accuracy of the prediction method is affected. This reduction in the yield and the accuracy of the prediction method is inversely proportional to the time in which the condensed water stays on the inner side of the condensing cover without collection because more drops will fall down into the basin of the solar-still. Different numbers of scraper motions per hour (NSM), that is
... Show MoreResearchers dream of developing autonomous humanoid robots which behave/walk like a human being. Biped robots, although complex, have the greatest potential for use in human-centred environments such as the home or office. Studying biped robots is also important for understanding human locomotion and improving control strategies for prosthetic and orthotic limbs. Control systems of humans walking in cluttered environments are complex, however, and may involve multiple local controllers and commands from the cerebellum. Although biped robots have been of interest over the last four decades, no unified stability/balance criterion adopted for stabilization of miscellaneous walking/running modes of biped