Preferred Language
Articles
/
bhfPNY8BVTCNdQwCiWKa
Improving the BURT’s Sensitivity using Noise Calibration Unit via Crab Nebula Observations
...Show More Authors

Radio observations from astronomical sources like supernovae became one the most important sources of information about the physical properties of those objects. However, such radio observations are affected by various types of noise such as those from sky, background, receiver, and the system itself. Therefore, it is essential to eliminate or reduce these undesired noise from the signals in order to ensure accurate measurements and analysis of radio observations. One of the most commonly used methods for reducing the noise is to use a noise calibrator. In this study, the 3-m Baghdad University Radio Telescope (BURT) has been used to observe crab nebula with and without using a calibration unit in order to investigate its impact on the signal. Radio observations of crab nebula have been carried out for different periods in 2022. Several parameters of the telescope have been calculated and analyzed using statistical measurements with and without using the noise calibration unit. Those parameters are receiver gain, system temperature, antenna temperature, and degree per flux unit. The results of this research revealed that the fluctuation sensitivity of BURT improved by about an order of magnitude, when the noise calibration unit is used. The root mean square error and the radiometer equation of the antenna temperature decreased to less than 33% and 10%, respectively in comparison to their initial values. In conclusion, the noise calibration unit plays a crucial role to improve the sensitivity of a radio telescope drastically.

Scopus Crossref
View Publication
Publication Date
Wed Oct 26 2022
Journal Name
Iraqi Journal Of Science
Gene Expression Analysis via Spatial Clustering and Evaluation Indexing
...Show More Authors

The density-based spatial clustering for applications with noise (DBSCAN) is one of the most popular applications of clustering in data mining, and it is used to identify useful patterns and interesting distributions in the underlying data. Aggregation methods for classifying nonlinear aggregated data. In particular, DNA methylations, gene expression. That show the differentially skewed by distance sites and grouped nonlinearly by cancer daisies and the change Situations for gene excretion on it. Under these conditions, DBSCAN is expected to have a desirable clustering feature i that can be used to show the results of the changes. This research reviews the DBSCAN and compares its performance with other algorithms, such as the tradit

... Show More
View Publication
Scopus (3)
Scopus Crossref
Publication Date
Thu Feb 02 2012
Journal Name
Education College Journal/al-mustansiriyah University
On Significance Testimator in Pareto Distribution Via Shrinkage Technique
...Show More Authors

In this paper, preliminary test Shrinkage estimator have been considered for estimating the shape parameter α of pareto distribution when the scale parameter equal to the smallest loss and when a prior estimate α0 of α is available as initial value from the past experiences or from quaintance cases. The proposed estimator is shown to have a smaller mean squared error in a region around α0 when comparison with usual and existing estimators.

Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
Pure And Applied Mathematics Journal
Memory Effects in Diffusion Like Equation Via Haar Wavelets
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Sat Aug 02 2025
Journal Name
Kerbala Journal Of Pharmaceutical Sciences
Determination of Methionine Via Chemiluminescence-Continuous Flow Injection Analysis
...Show More Authors

The research work represent a fast and simple method for the determination of methionine using chemiluminescence for the methionine-sodium hydroxide-luminol for the generation of a chemiluminesecent derivative of luminal. The emission was measured by continuous flow analysis made sample size of 83µL was used.Response versus concentration extended from 0.2-20 mM.L-1 with a percentage linearity of 96.17% or with 99.17% percentage of linearity for the range 0.6-20 mM.L-1. Reaching to a L.O.D. at (S/N=3) for 5 µM.L-1 from the gradual dilution for the minimum concentration in the calibration graph with a repeatability of less than 0.5% (n=10). A comparison was made between the new developed method with the classical method for the spectrophoto

... Show More
View Publication
Publication Date
Tue Dec 16 2008
Journal Name
Iraqi Journal Of Laser
Primary Diagnosis of Abnormal Urine via Auto Fluorescence Process
...Show More Authors

The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Proceeding Of The 1st International Conference On Advanced Research In Pure And Applied Science (icarpas2021): Third Annual Conference Of Al-muthanna University/college Of Science
Approximation fixed point theorems via generalized like contraction mappings
...Show More Authors

View Publication
Crossref (1)
Scopus Crossref
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Primary Diagnosis of Abnormal Urine via Auto Fluorescence Process
...Show More Authors

The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 01 2015
Journal Name
Journal Of Economics And Administrative Sciences
The Monitoring Role of the Governmental council in improving the performance of local Committees: Applied Research in the Wasit Governmental Council
...Show More Authors

            The research aims to identify the elements of performance supervisory good and effective and availability in the Governmental council through examination and analysis of the reality and practice of censorship in this Council through study and evaluate the characteristics of the regulatory effective upon which the Governmental council in the performance of his work and knowledge of their adequacy by comparing the established criteria , and determine the effect of characteristics supervisory the performance standards for the Governmental council, Based search to two assumptions key to check the level of the relationship and the influence of the dimensions of the con

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 30 2023
Journal Name
Iraqi Journal Of Science
Study the Effect of Oxygen on Coronene Electronic and Spectroscopic Properties via the Density Functional Theory (DFT)
...Show More Authors

    The electronic properties (such as energy gap HOMO levels. LUMO levels, density of state and density of bonds in addition to spectroscopic properties like IR spectra, Raman spectra, force constant and reduced masses as a function of frequency) of coronene C24 and reduced graphene oxide C24OX , where x=1-5, were studied.. The  methodology employed was  Density Functional Theory (DFT) with Hybrid function B3LYP and 6-311G** basis sets. The energy gap was calculated for C24 to be 3.5 eV and for C24Ox was from 0.89 to 1.6862 eV  for x=1-5 ,respectively.   These energy gaps values are comparable to the measured gap of Graphene (1-2.2 eV). The spectroscopic properties were  compared with experimental measurements, specificall

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Chemical Methodologies
Determination of the Quantity of Losartan Active Ingredient in the Medication Formulations via Turbidimetric-Flow Injection Technique
...Show More Authors

Scopus (15)
Scopus