The experiment aimed to Manufacture a device for checking the nozzles and testing its efficiency and to study the effect of research factors on the studied traits. The device was manufactured locally through using materials available in the Iraqi market. The system is Both Hydraulic and electronic (ISO 5682-1)1 relay on sensors technology and the test platform was built and designed on a movable trolly at the department of Agricultural Machines and Equipment / College of Agricultural Science / University of Baghdad. The design includes the use of mechanical water pump and electrical AC water pump. The design includes a nozzle holder that can accommodate three nozzles per test. The design also consists of spreading wings and stationary wing that can accommodate 50 vessels and 50 ultra-sonic sensors. All that is controlled by a main control unit which consists of three branch modules (each one of them is responsible to collect and analyze data from several sensors on each of the wings. The idea behind the design is to merge between actual spraying and the use of electronic sensors to analyze the size of the sprayed liquid in each of the vessels, the concept of the design is based upon Volumetric distribution of the liquid. The concept of the device was based on using ultra sonic sensors to measure the volumetric distribution of liquids. The experiment aimed to determine the effects of these factors on flow rate, spraying angle, sprayed area, spraying swath, volumetric distribution (CV), and symmetry. The experiment was conducted at the college of Agricultural science, Baghdad University. The results showed that the spraying pressure had a non-significant effect on flow rate. However, increasing the pressure from 3.0 to 5.0 and then to 7.0 bar resulted in flow rates of 1.314, 1.286, and 1.36 l/m, respectively. The status of the nozzle (new or worn) did not significantly affect the flow rate, with new nozzles registering a slightly higher flow rate of 1.327 l/m compared to worn nozzles (1.312 l/m). On the other hand, the type of nozzle had a significant impact on flow rate, with plastic, brass, and steel nozzles registering flow rates of 1.243, 1.422, and 1.29 l/m, respectively. Regarding the spraying angle, the results indicated that the spraying pressure had a significant effect. Increasing the pressure from 3.0 to 5.0 and then to 7.0 bar resulted in spraying angles of 132, 132, and 136 degrees, respectively. The nozzle status significantly affected the spraying angle, with worn nozzles resulting in a higher angle of 137 degrees compared to new nozzles (130 degrees). However, the type of nozzle did not significantly affect the spraying angle. For the sprayed area, the spraying pressure had a significant effect, with higher pressures resulting in larger sprayed areas. Worn nozzles also significantly increased the sprayed area compared to new nozzles. The type of nozzle had a significant impact on the sprayed area, with plastic, brass, and steel nozzles resulting in areas of 70.4, 80.44, and 89.16 cm2, respectively. The experiment proved that nozzles must be tested periodically, otherwise they start to perform beyond the parameters they were designed to perform with.
Background: Coated aesthetic archwires are currently the existing solutions for the esthetic problem, but the color of these archwires tends to change overtime. This study was aimed to evaluate the color stability of different types of esthetic archwires from four different companies at different time periods after immersion of two different staining drinks which are tea and Pepsi cola. Materials and methods: 48 specimens were prepared, each specimen contains 10 aesthetic archwires; and were divided according to type of solution into two groups: A (tea) &B (Pepsi cola); each group contained 24 specimens (12 specimens were immersed in the staining solution as 4 specimens for each time intervals and 12 specimens were immersed in distilled wa
... Show More<span lang="EN-US">Diabetes is one of the deadliest diseases in the world that can lead to stroke, blindness, organ failure, and amputation of lower limbs. Researches state that diabetes can be controlled if it is detected at an early stage. Scientists are becoming more interested in classification algorithms in diagnosing diseases. In this study, we have analyzed the performance of five classification algorithms namely naïve Bayes, support vector machine, multi layer perceptron artificial neural network, decision tree, and random forest using diabetes dataset that contains the information of 2000 female patients. Various metrics were applied in evaluating the performance of the classifiers such as precision, area under the c
... Show MoreIn this work the corrosion behavior of Ti-6Al-4V alloy was studied by using galvanostatic measurements at room temperature in different media which includ sodium chloride (food salt), sodium tartrate (presence in jellies, margarine, and sausage casings,etc.), sodium oxalate (presence in fruits, vegetables,etc.), acetic acid (presence in vinegar), phosphoric acid (presence in drink), sodium carbonate (presence in 7up drink,etc.), and sodium hydroxide in order to compare.
Corrosion parameters were interpreted in th
... Show MoreThis study is concerned with a survey of seven species belonging to seven genera under two families and two orders found in some different areas of the Tigris River, especially since these areas have not been surveyed for a long time, and an attempt to identify the existing species at the present time after the recent water scarcity of the Tigris and Euphrates rivers and all water bodies interior of Iraq and the impact of this scarcity on the fish diversity found in some areas of the Tigris River in Baghdad.
Background: The fracture of instruments within root canal during endodontic treatment is a common incidence, fracture because of fatigue through flexure occurs due to metal fatigue, this study aimed to assess the effect of curvature angle and rotational speed on the cyclic fatigue of different type of Endodontic NiTi Rotary Instruments and compare among them. Materials and method: Three types of rotary instruments with tip size 0.25: ProTaPer F2 (Densply, Malifier) Revo-S SU( 0.06 taper, MicroMega) and RaCe system (0.06 taper, FKG, Dentaire), Forty file of each instrument were used within two canals with angle of curvature (40 &60 )at two speed (250&400)RPM, twelve group were formed for all instruments(total number=120),ten file fo
... Show MoreThe research aims at determining the main reason for the deterioration of the services and determining the correct method of distributing the funds to the administrative and administrative units. The discrepancy between the size of the financial allocations and the municipal services was the main research problem. Therefore, the researcher identified the gaps in municipal services by the concerned departments and compared them with The percentage of funds obtained through the work of a checklist for each of the directorates concerned. The researcher studied the specific criteria for these services, which were approved by the Ministry of Construction, Housing, Municipalities, and Public Works, and compared them wi
... Show MoreThe molluscum contagiosum virus (MCV) is a dermatotropic poxvirus. The causative agent of molluscum contagiosum (MC) is nonlethal, common and worldwide. Additionally, little inflammation is associated with MC papules. The present study aims to evaluate the immune status of MC patients by measuring the level of immunoglobulins IgG and IgM by using the radial immune diffusion assay (RIA) and the level of interleukin 18 receptor 1 (IL-18R1) by the Enzyme-linked immunosorbent assay (ELISA).The study is conducted during November 2013 to April, 2014 in outpatient clinic of Baquba Teaching Hospital. There are 75 patients, diagnosed with clinical lesions of MCV on different areas of the body, whose age is ranged between 2-50 years including 40(53.
... Show MoreBackground: To evaluate the ISO depth of cure of bulkfill composites and depth of cure which determined by Vickers microhardness test. Materials and Methods: Bulkfill resin composite specimens (n=150) were prepared of three bulkfill composite materials (TetricEvo Ceram, Quixfil and SDR) and light cured by Flash max p3 for 3, 10, 20 seconds and by wood pecker for 10, 20 seconds respectively, a mold was filled with one of the three bulkfill composites and light cured. The specimens removed from the mold and scraped by plastic spatula and the remaining length (absolute length) was measured which represent the ISO depth of cure. After that the specimens were returned into the mold and a microhardness indentation device applied on the specimen
... Show More