In this work the interaction of plasma jet with water and hydrogen peroxide liquids used for assisted teeth bleaching by plasma jet had been study. A homemade plasma jet system was used. The plasma jet supply by 15 W electrical power generated by high voltage power supply of 9.6 kV peak to peak and frequency of 33 kHz .this power supply generate high electric field on electrodes that would be enough to ionize the argon gas. Some important agents were study such as the effect of the Ar gas flow rates on the length of the plasma jet, the influence of plasma jet on some properties of water and two hydrogen peroxide concentrations 25 % and 30 % like pH, conductivity and liquid temperature for different exposure time. The liquids temperature was measured by digital infrared thermometer, the gas flow rate were measured by gas flow meter, the pH, and the conductivity was measured by pH conductivity ultra-meter. The results illustrated that the conductivity and liquid temperature increase with increasing of exposure time. It can be conclude that the liquid properties were changed less than the boundaries that could affect adversely to the cells that located in the plasma jet.
An experiment was conducted in the field, Department of field crops , College of Agriculture , University of Baghdad during fall season 2011. To study the effect of interaction of water stress and hydrogen peroxide and potassium on the growth and yield of maize plant cultivar Bohooth 106. It Included the study of three levels of water stresses of 40 , 60 and 80% of the available water , (D1 , D2 and D3) respectively, three levels of hydrogen peroxide of concentrations (0 , 15 and 30 Mm), and foliar application of potassium at the concentration of 3000 mg K. L-1 K2SO4 and without applied potassium.. Split – Split with RCBD design with three replications were used. The levels of water stresses occupied the main plots , potassium lev
... Show MoreThis study compares the effects of plasma jet and plasma-activated water on teeth root canals contaminated with Escherichia coli bacteria. A plasma jet system was developed for biological purposes that operate at atmospheric pressure. The plasma jet works with argon gas and is generated by a power supply, which supplies a sinusoidal alternating voltage of 12 kV of 20 kHz frequency. The system was optically diagnosed, as it was found that the peaks of the nitrogen spectrum were obtained at the wavelength (300- 450) nm with the appearance of hydroxide peaks at 380 nm. Extracted teeth with one root canal were used, which were contaminated with bacteria and divided into two groups to be treated with a plasma jet and plasma-activated
... Show MoreIn this study, method for experimentally determining the electron density (ne) and the electron temperature (Te) in the atmospheric Argon plasma jet is used; it is based on optical emission spectroscopy (OES). Boltzmann plot method used to calculate these parameters measured for different values of gas flow rate. The results show that the electron temperature decreasing with the increase of gas flow rate also indicates an increasing in the electron density of plasma jet with increasing of gas flow rate.
Iodine-doped polythiophene thin films are prepared by aerosol assisted plasma jet polymerization at atmospheric pressure and room temperature. The doping of iodine was carried out in situ by employing iodine crystals in thiophene monomer by weight mixing ratios of 1%, 3%, 5% and 7%. The chemical composition analyses of pure and iodine-doped and heat-treated polythiophene thin films are carried out by FTIR spectroscopy studies. The optical band gaps of the films are evaluated from absorption spectrum studies. Direct transition energy gaps are determined from Tauc plots. The structural changes of polythiophene upon doping and the reduction of optical band gap are explained on the basis of the results obtained from FTIR spectroscopy, UV–V
... Show MoreCrystalline silicon (c-Si) has low optical absorption due to its high surface reflection of incident light. Nanotexturing of c-Si which produces black silicon (b-Si) offers a promising solution. In this work, effect of H2O2 concentrations towards surface morphological and optical properties of b-Si fabricated by two-step silver-assisted wet chemical etching (Ag-based two-step MACE) for potential photovoltaic (PV) applications is presented. The method involves a 30 s deposition of silver nanoparticles (Ag NPs) in an aqueous solution of AgNO3:HF (5:6) and an optimized etching in HF:H2O2:DI H2O solution under 0.62 M, 1.85 M, 2.47 M, and 3.7 M concentrations of H2O<
... Show MoreIn this study a new antiseptic was formulated and tested to match the effectiveness against microorganisms. The formulation consisted of Povidone - Iodine (PVP-I) (10%), H2O2 (3%) and Aloe Vera gel (pure). Different ratios of these materials were prepared within the acceptable range of pH for an antiseptic (3-6). The prepared samples were tested. The In Vitro test was performed by using four bacteria, two were Gram-Positive (Staphylococcus aureus and Bacillus cereus) and two were Gram-Negative (Escherichia coli and Pseudomonas aeruginosa). The new antiseptic showed 100% killing rate for E. coli, Ps. aeruginosa and S. aureus and 96.4667% killing rate for B. cereus. When the new antiseptic was compared with two common
... Show MoreIn this study, gold nanoparticles (AuNPs) were synthesized using a plasma jet system at different exposure times. Using ultraviolet, visible spectra, X-ray diffraction, the nanoparticles were characterized (XRD). A Plasmon surface resonance concentrated at 530, 540, and 533 nm for the prepared AuNPs. The pattern of XRD showed that the extreme peaks of the film reflect crystalline existence. The face-centered cubic structure of the gold nanoparticles was prepared for all samples, with an average crystallite size of 25-40 nm. The effect of AuNPs in vivo on liver function levels was measured. For all doses, we notice an increase in the ranks of liver function in the blood during the period of dosing, and it begins to decrease when the dosi
... Show MoreThe research aims to develop and build a plasma jet system operating under atmospheric pressure.for biological purposes. The advanced plasma system consists of a power supply and a plasma torch. The source of the development of the system is a previous laboratory system that was developed by changing the voltage and frequency of the power supply, as the power provider equips the system with a voltage in the form of a sine wave whose value is fixed at about (7.5kV) peak to peak and its frequency is about (28 kHz). The plasma torch consists of a teflon tube with of width of (10 m ) located at (10mm) from the end of the tube. The current waveform and voltage wave were measured using a current and voltage sensor and an oscilloscop
... Show MoreThis research studies the effect regarding two plasma types, plasma jet and plasma-activated water (PAW), on tooth root canal bacteria Enterococcus faecalis. The plasma jet works with argon gas, and it is generated by a power supply that operates at alternating high voltages in the form of a sinusoidal wave with peak-to-peak value of about 12 kV at a frequency of 30 KHz and its power is about 200 watts. This plasma was utilized directly to treat the tooth canal and indirectly by activating the water that was used later for treating the Enterococcus faecalis bacteria that are present in the tooth root. Pure distilled water was treated by plasma jet for one hour at flow rate 1 . Plasma water activated by plasma contains
... Show More