We consider the problem of calibrating range measurements of a Light Detection and Ranging (lidar) sensor that is dealing with the sensor nonlinearity and heteroskedastic, range-dependent, measurement error. We solved the calibration problem without using additional hardware, but rather exploiting assumptions on the environment surrounding the sensor during the calibration procedure. More specifically we consider the assumption of calibrating the sensor by placing it in an environment so that its measurements lie in a 2D plane that is parallel to the ground. Then, its measurements come from fixed objects that develop orthogonally w.r.t. the ground, so that they may be considered as fixed points in an inertial reference frame. Moreover, we consider the intuition that moving the distance sensor within this environment implies that its measurements should be such that the relative distances and angles among the fixed points above remain the same. We thus exploit this intuition to cast the sensor calibration problem as making its measurements comply with this assumption that “fixed features shall have fixed relative distances and angles”. The resulting calibration procedure does thus not need to use additional (typically expensive) equipment, nor deploy special hardware. As for the proposed estimation strategies, from a mathematical perspective we consider models that lead to analytically solvable equations, so to enable deployment in embedded systems. Besides proposing the estimators we moreover analyze their statistical performance both in simulation and with field tests. We report the dependency of the MSE performance of the calibration procedure as a function of the sensor noise levels, and observe that in field tests the approach can lead to a tenfold improvement in the accuracy of the raw measurements.
This study was conducted to investigate phytoplasma causing a virescence disease on Arabic jasmine Jasminum sambac based on microscopy and molecular approaches. Samples were collected from symptomatic Arabic jasmine plants grown in nurseries in Baghdad-Iraq. Specimens from infected plants were prepared and Dienes stained for light microscopy examination. Phytoplasma were detected in infected plants by polymerase chain reaction (PCR) using P1/P7 and SecAfor1/SecArev3 Candidatus Phytoplasma specific primer sets. Light microscopy test showed symptomatic Arabic jasmine plants were phytoplasms infected when phloem tissues were stained with a dark blue color. PCR test confirmed the symptomatic plants were phytoplasms infected when SecAfor1/Sec
... Show MoreThe present study aimed to investigate the morphological description and histological structure of Gallbladder in the adult local chicken bird. The morphological description and histological structure of the Gallbladder in the local chicken Gallus gallus domesticus found in the form of a cystic, spindle or pear-shaped, dark green color, located within the visceral abdominal side of the right lobe of the liver, histologically it was found that its wall consisted of three tunicae. The first tunica is mucosa which consists of an epithelial lining layer and lamina propria layer, while the muscularis mucosa was missing. The second tunica is musclaris, which is composed of smooth circularly arranged muscle fibers, and the third tunica is serosa o
... Show MoreThe study have been conducted to estimated the concentration levels of heavy metals in samples of solid particles residue which collected randomly from street dust that produced with neglected municipality wastes in Baghdad City. Samples were collecting from services and dwelling street in Elmashtal region in Resapha side and Albaya regions in Karkh side at Baghdad City, regions characterized with different activities, a qualities analysis for the compounds doing with the following tests: 1- By using soil sieves was fragmented and limited the particulates of dust especially the dangerous types which associated with dust compounds and air pollution. 2- Digesting and analyzing of samples have been
... Show MoreQuick and accurate quaternary mixture resolution of furosemide (FURO), carbamazepine (CARB), diazepam (DIAZ) and carvedilol (CARV) by using derivative spectrophotometric method was performed. FURO and CARV were determined by means of first (D1), second (D2), third (D3) and fourth (D4) derivative spectrophotometric methods, CARB was determined by using D1, D2, D3 derivatives, while D1 and D2 were used for the determination of DIAZ. The recommended methods were verified using laboratory prepared mixtures and then successfully applied for the pharmaceutical formulations analysis of the cited drugs. The results obtained revealed the efficiency of the proposed methods as quantitative tool of analysis of the quaternary mixture with no requirement
... Show MoreThe study aimed to identify the degree of teaching competencies and job satisfaction of the teachers of physical education in the province of Baghdad, and then find the relationship between them. Use the descriptive approach in the style of associative relationships, the research community represented by teachers of physical education in the departments of education Karh (first, second, third) in the province of Baghdad. (522) teachers and (324) school principals distributed in (324) medium within the administrative configurations of these directorates for the academic year (2016 - 2017). The measure (teaching competencies) included (47) words distributed across seven areas. And the measure of (job satisfaction) included (15) words. After t
... Show MoreThere are numerous bidirectional interactions between the reproductive system and the liver. Sex steroids regulate metabolic health through signaling effects in both peripheral and central metabolic tissues, including adipose tissue, liver, skeletal muscle, and brain, and have a role in the etiology of structural and functional liver diseases. Blood samples were obtained from 90 healthy women (control group) and 90 women that have hormonal changes (patients’ group). The levels of reproductive hormones (follicle stimulation hormone/FSH, luteinizing hormone/LH, estradiol/E2, progesterone/P4) were measured by using fully automated Cobas E411, whereas those of liver enzymes (alanine transaminase /ALT, aspartate aminotransferase/AST, a
... Show More