Preferred Language
Articles
/
bBicCpUBVTCNdQwCCiQp
No-Core optical fibers sensor for detecting hemoglobin concentration (HB) based on the Surface Plasmon resonance.
...Show More Authors

In this work, a fiber-optic biomedical sensor was manufactured to detect hemoglobin percentages in the blood. SPR-based coreless optical fibers were developed and implemented using single and multiple optical fibers. It was also used to calculate refractive indices and concentrations of hemoglobin in blood samples. An optical fiber, with a thickness of 40 nanometers, was deposited on gold metal for the sensing area to increase the sensitivity of the sensor. The optical fiber used in this work has a diameter of 125μm, no core, and is made up of a pure silica glass rod and an acrylate coating. The length of the fiber was 4cm removed buffer and the splicing process was done. It is found in practice that when the sensitive refractive index increases, the resonant wavelength increases due to the decrease in energy.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jun 15 2024
Journal Name
Journal Of Legal Sciences
The period for challenging the unconstitutionality of the medium-term general budget law In light of the decision of the Federal Supreme Court No. 155 and its unified No. 163 / Federal / 2022
...Show More Authors

يتعرض قانون الموازنة العامة الاتحادية للطعن بعدم الدستورية كغيره من القوانين، بل أن الطعن فيه يكاد يكون سنوياً حال نشره في الجريدة الرسمية ، وتوجه إليه المطاعن بعدم الدستورية إما عن إجراءات تشريعه أو لمضامينه المتعارضة مع الدستور نصاً أو روحاً ، ولكنّه إذا كانت مدة الطعن بعدم دستورية القوانين كافة متاحة دون قيد زمني محدد ولا تتطلب سوى إجراءات إقامة الدعوى العامة وأخصها قيام شرط المصلحة في حالة الدعوى ال

... Show More
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Matec Web Of Conferences
Brain Tumour Detection using Fine-Tuning Mechanism for Magnetic Resonance Imaging
...Show More Authors

In this paper, new brain tumour detection method is discovered whereby the normal slices are disassembled from the abnormal ones. Three main phases are deployed including the extraction of the cerebral tissue, the detection of abnormal block and the mechanism of fine-tuning and finally the detection of abnormal slice according to the detected abnormal blocks. Through experimental tests, progress made by the suggested means is assessed and verified. As a result, in terms of qualitative assessment, it is found that the performance of proposed method is satisfactory and may contribute to the development of reliable MRI brain tumour diagnosis and treatments.

View Publication
Scopus (3)
Scopus Crossref
Publication Date
Tue Feb 21 2017
Journal Name
Biomechanics And Modeling In Mechanobiology
A novel method for non-invasively detecting the severity and location of aortic aneurysms
...Show More Authors

The influence of an aortic aneurysm on blood flow waveforms is well established, but how to exploit this link for diagnostic purposes still remains challenging. This work uses a combination of experimental and computational modelling to study how aneurysms of various size affect the waveforms. Experimental studies are carried out on fusiform-type aneurysm models, and a comparison of results with those from a one-dimensional fluid–structure interaction model shows close agreement. Further mathematical analysis of these results allows the definition of several indicators that characterize the impact of an aneurysm on waveforms. These indicators are then further studied in a computational model of a systemic blood flow network. This demonstr

... Show More
View Publication Preview PDF
Scopus (34)
Crossref (31)
Scopus Clarivate Crossref
Publication Date
Sat Jun 25 2022
Journal Name
International Journal Of Drug Delivery Technology
Statistical Design based on Response Surface Methodology to Optimize the Production of a Yellow Pigment by Streptomyces thinghirensis AF7
...Show More Authors

Although its wide utilization in microbial cultures, the one factor-at-a-time method, failed to find the true optimum, this is due to the interaction between optimized parameters which is not taken into account. Therefore, in order to find the true optimum conditions, it is necessary to repeat the one factor-at-a-time method in many sequential experimental runs, which is extremely time-consuming and expensive for many variables. This work is an attempt to enhance bioactive yellow pigment production by Streptomyces thinghirensis based on a statistical design. The yellow pigment demonstrated inhibitory effects against Escherichia coli and Staphylococcus aureus and was characterized by UV-vis spectroscopy which showed lambda maximum of

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Lecture Notes Of The Institute For Computer Sciences, Social Informatics And Telecommunications Engineering
Sensor Data Classification for the Indication of Lameness in Sheep
...Show More Authors

View Publication Preview PDF
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Sep 30 2020
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Activity- Based Costing technology and its role in Cost Guidance: An Applied Study at the General Company for Textile and Leather Industries - Leather plant - Factory No. (7)
...Show More Authors

Iraqi industrial units face strong competition due to many problems including1- high production costs2- weak interest in studying the market3- lack of government support for their products4- dumping the market with imported products with specifications and a competitive price as well as adopting the traditional cost system in calculating costs that do not provide appropriate information for pricing decisions Which requires studying and analyzing these problems and dealing with them by adopting modern technologies so that they can compete, so the research aims to show the knowledge bases of technology Activity- Based Costing, with an indication of the role of technology Activity- Based Costing in rationalizing the tax In, and the

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 03 2013
Journal Name
Baghdad Science Journal
Study the effects of bromothymol blue material on the optical properties for polystyrene (PS).
...Show More Authors

Films of pure polystyrene (ps) and doped by bromothymol blue material with percentages(4%) prepared by using casting technique in room temperature , the absorption and transmission spectra has been recorded in the wavelength rang (200-900)nm and calculated refractive index , reflectivity, real and imaginary parts of dielectric constant and extinction coefficient . this study has been done by recording the absorption and transmission spectra by using spectrophotometer .

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Influence of water absorption on fatigue behavior for chopped and woven-glass-fibers-reinforced PMMA denture
...Show More Authors

The influence of fiber orientation and water absorption on fatigue crack growth resistance for cold cure acrylic (PMMA) reinforced by chopped and woven -glass-fibers were investigated. A weight of 2 g for chopped fibers and the same weight for woven -glass-fibers (one layer) were used to prepare samples. Some of these samples would storage in dry condition; the others were immersed in water for 15 days. Fatigue test was carried out. The results shows that, for PMMA, the initial bending stress for dry specimen was 3.392 N/cm2 and the number of cycles were 1364, the initial bending stress for wet samples was 4.20 N/cm2, and the number of cycles was 2411. The samples would cut in two pieces because of the cracks would propagated fast during

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 23 2026
Journal Name
Journal Of Legal Sciences
A comparative study between the federal investment law No. 13 of 2006 and the Investment Law Kurdistan No. 4 of 2006
...Show More Authors

View Publication
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
Design of Tunable Optical Band Pass Filter based on in-Line PM-Mach Zehnder Interferometer
...Show More Authors

In this paper, tunable optical band-pass filters based on Polarization Maintaining Fiber –Mach Zehnder Interferometer presented. Tunability of the band-pass filter implemented by applying different mechanical forces N on the micro-cavities splicing regions (MCSRs). The micro-cavity formed by using three variable-lengths of single-mode polarization-maintaining fiber with (8, 16, 24) cm lengths, splice between two segments of (SMF-28) with (26, 13) cm lengths, using the fusion splicing technique.  Ellipsoidal shape micro-cavities experimentally achieved parallel to the propagation axis having dimensions between (12-24) μm of width and   (4-12) μm of length. A micro-cavity with width and length as high as 24 μm and 12 μ

... Show More
View Publication Preview PDF