Preferred Language
Articles
/
bBYorIwBVTCNdQwC2v6c
A Systematic Review of Brain-Computer Interface Based EEG
...Show More Authors

The futuristic age requires progress in handwork or even sub-machine dependency and Brain-Computer Interface (BCI) provides the necessary BCI procession. As the article suggests, it is a pathway between the signals created by a human brain thinking and the computer, which can translate the signal transmitted into action. BCI-processed brain activity is typically measured using EEG. Throughout this article, further intend to provide an available and up-to-date review of EEG-based BCI, concentrating on its technical aspects. In specific, we present several essential neuroscience backgrounds that describe well how to build an EEG-based BCI, including evaluating which signal processing, software, and hardware techniques to use. Individuals discuss Brain-Computer Interface programs, demonstrate some existing device shortcomings, and propose some eld’s viewpoints.

Crossref
View Publication
Publication Date
Sat Oct 01 2022
Journal Name
Therapeutic Delivery
Particles-based Medicated Wound Dressings: A Comprehensive Review
...Show More Authors

View Publication
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Mar 07 2022
Journal Name
International Journal Of Environmental Research And Public Health
Efficacy of MMP-8 Level in Gingival Crevicular Fluid to Predict the Outcome of Nonsurgical Periodontal Treatment: A Systematic Review
...Show More Authors

Purpose: To explore whether baseline matrix metalloproteinase (MMP)-8 level in gingival crevicular fluid (GCF) (exposure) can predict the outcome (reduction in probing pocket depth (PPD) (outcome)) of nonsurgical periodontal therapy (NSPT) (manual or ultrasonic or both) in patients with periodontitis (population/problem) after 3 months. Methods: Six databases (PubMed, Cochrane library, ProQuest, Ovid, Scopus, EBSCO) were searched for relevant articles published until 30 July 2021. Retrieved articles were passed through a three-phase filtration process on the basis of the eligibility criteria. The primary outcome was the change in PPD after 3 months. Quality of the selected articles was assessed using Cochrane Risk of Bias tool (RoB2

... Show More
View Publication
Scopus (11)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Mon Nov 01 2010
Journal Name
Journal Of Systems And Software
Development of Java based RFID application programmable interface for heterogeneous RFID system
...Show More Authors

View Publication
Scopus (7)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sat Aug 01 2020
Journal Name
Surgical Neurology International
Unilateral absence of the internal carotid artery associated with anterior communicating artery aneurysms: Systematic review and a proposed management algorithm
...Show More Authors
Background:

Absence or hypoplasia of the internal carotid artery (ICA) is a rare congenital anomaly that is mostly unilateral and highly associated with other intracranial vascular anomalies, of which saccular aneurysm is the most common. Blood flow to the circulation of the affected side is maintained by collateral pathways, some of which include the anterior communicating artery (Acom) as part of their anatomy. Therefore, temporary clipping during microsurgery on Acom aneurysms in patients with unilateral ICA anomalies could jeopardize these collaterals and place the patient at risk of ischemic damage. In this paper, we review the literature on cases with a unilaterally absent ICA associa

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (8)
Scopus Crossref
Publication Date
Sun Apr 30 2023
Journal Name
Al-kindy College Medical Journal
Circulating Interleukin-23 Levels in Rheumatoid Arthritis and its Relationship to Disease Activity: a Systematic Review with Meta-Analysis
...Show More Authors

Background: Rheumatoid arthritis (RA) is a chronic and systemic autoimmune disease that is characterized by severe synovial inflammation, cartilage erosion, bone loss, and generalized vasculopathy. Although the immunologic mechanism of RA is still unclear, it is now thought to be a primarily Th17-driven disease. Along with other factors, IL-23 stimulates the expansion of Th17 cells from naive CD4+ T cells.

Objective: The objective of this study is to assess the circulating levels of interleukin (IL)-23 in rheumatoid arthritis (RA) and determine the correlation between plasma/serum IL-23 levels and disease activity. So, we performed a systematic review with meta-analysis comparing

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Thu Apr 01 2021
Journal Name
Computer Methods And Programs In Biomedicine
A hybrid approach based on multiple Eigenvalues selection (MES) for the automated grading of a brain tumor using MRI
...Show More Authors

View Publication
Scopus (36)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Sat Jul 22 2023
Journal Name
Journal Of Engineering
Multiwavelet based-approach to detect shared congestion in computer networks
...Show More Authors

Internet paths sharing the same congested link can be identified using several shared congestion detection techniques. The new detection technique which is proposed in this paper depends on the previous novel technique (delay correlation with wavelet denoising (DCW) with new denoising method called Discrete Multiwavelet Transform (DMWT) as signal denoising to separate between queuing delay caused by network congestion and delay caused by various other delay variations. The new detection technique provides faster convergence (3 to 5 seconds less than previous novel technique) while using fewer probe packets approximately half numbers than the previous novel technique, so it will reduce the overload on the network caused by probe packets.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jul 06 2022
Journal Name
Journal Of Al-qadisiyah For Computer Science And Mathematics
Pixel Based Techniques for Gray Image Compression: A review
...Show More Authors

Currently, with the huge increase in modern communication and network applications, the speed of transformation and storing data in compact forms are pressing issues. Daily an enormous amount of images are stored and shared among people every moment, especially in the social media realm, but unfortunately, even with these marvelous applications, the limited size of sent data is still the main restriction's, where essentially all these applications utilized the well-known Joint Photographic Experts Group (JPEG) standard techniques, in the same way, the need for construction of universally accepted standard compression systems urgently required to play a key role in the immense revolution. This review is concerned with Different

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sun Aug 06 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Computer Analysis Of A simplified Eye Model
...Show More Authors

  Computer analysis of simple eye model is performed in the present work by using the Zemax optical design software 2000E . The most important optical parameters of the eye were calculated such as the effective focal length (EFL) , the image spot size at the retina and found to be in a reasonable agreement with the values needed for the laser retinal treatment .The present eye model leads to an effective wavelength and we found the image spot diagram at the surface of the retina and the wavefront error which are provided at zero field angle. This gives a good evidence of the validity of the model in one hand, and can be used to determine the compatibility of any optical design intended for visual applications. By using the pulse fre

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 01 2023
Journal Name
Advances In Mechanical Engineering
3D-shape formation of blood vessels based on computer aided design system
...Show More Authors

This paper proposes and tests a computerized approach for constructing a 3D model of blood vessels from angiogram images. The approach is divided into two steps, image features extraction and solid model formation. In the first step, image morphological operations and post-processing techniques are used for extracting geometrical entities from the angiogram image. These entities are the middle curve and outer edges of the blood vessel, which are then passed to a computer-aided graphical system for the second phase of processing. The system has embedded programming capabilities and pre-programmed libraries for automating a sequence of events that are exploited to create a solid model of the blood vessel. The gradient of the middle c

... Show More
View Publication
Scopus Clarivate Crossref