This research aimed to explore the use of foamed concrete (FC), a lightweight concrete, by replacing sand with crushed plastic from washing machines to improve environmental and thermal properties. The primary components included traditional materials like cement, water, and a foaming agent, along with the innovative use of waste plastic (WP). Utilizing Minitab software, the study applied the Response Surface Method to optimize mix designs, reducing the experimental mixtures to 31, which were then tested for dry density, porosity, water absorption, shrinkage, compressive strength, splitting tensile strength, and thermal conductivity. Results indicated a significant 24% reduction in dry density when using plastic as fine and coarse aggregates, yielding superior thermal insulation. The statistical approach facilitated a regression model correlating mix ingredients with strength and density. Notably, adding fly ash to the plastic aggregate mix maintained strength comparable to that of conventional mixes. The optimal mix, containing 20% fine and 70% coarse WP, achieved the highest density reduction with minimal strength loss. The study concludes that incorporating crushed plastic waste in FC significantly reduces density while retaining strength, offering both environmental benefits and enhanced thermal insulation, thereby presenting a sustainable solution for construction. Additionally, this innovative approach highlights the potential for large-scale WP use, reducing landfill pressure, decreasing carbon footprint, and promoting circular economy practices within the construction industry, paving the way for future green building innovations.
Back ground: During acrylic resin processing, the mold must be separated from the surface of the gypsum to prevent liquid resin from penetrating into the gypsum, and water from the gypsum seeping into the acrylic resin. For many years, tin foil was the most acceptable separating medium, and because it's difficult to apply, a tin-foil substitute is used. In this study, olive oil is used as an alternative to tin foil separating medium for first time, so the aim of the study was to evaluate its effect as a separating medium on some physical properties such as (surface roughness, water sorption and solubility) of acrylic resins denture base comparing it with those processed using tin-foil and tin foil substitute such as (cold mold seal) separat
... Show MoreThis research aims to examine the role of global green finance as a critical driver of both economic and environmental sustainability within small and medium-sized agricultural enterprises (SMEs) in Iraq. Utilizing a convergent mixed-methods framework, the study integrates qualitative interviews with key stakeholders and a quantitative survey of 300 agricultural SMEs to assess the barriers, enablers, and institutional conditions influencing the adoption of green finance. The findings indicate that, despite growing awareness and substantial latent demand for sustainability-linked investments, adoption is significantly constrained by institutional fragmentation, regulatory ambiguity, and resource limitations at the firm level. Grounded in Ins
... Show MoreBreast cancer is among the primary causes of death among Iraqi women and is a serious worldwide health concern. ALK or anaplastic lymphoma kinase, is connected to several cancers, including breast cancer.. The goal of this research was to assess the prevalence of anaplastic lymphoma kinase (ALK) with Alkaline phosphatise (ALP) and Lactate dehydrogenase (LDH) together as diagnostic markers. The study comprised 60 patients with metastatic breast cancer and 60 healthy volunteers. The blood levels of the enzymes (ALP), (LDH), and ALK in Iraqi breast cancer patients are compared to those of healthy controls. It was shown that compared to healthy people, patients had breast cancer noticeably greater levels of ALK, ALP, and NDH .These biomarkers m
... Show MoreTransient drop in the heart beat or transient heart block (AVB) may be consider the main cause of syncope or presyncope inpatients with bifascicular block and syncope According to the Guidelines for cardiac pacing pacemaker consider part of treatment. Aims of our study were to evaluate whether there is role for EPS in patients BFB and to evaluate the symptoms after pacing. 42 patients were enrolled in this study, with mean age value (63.4± 12.2years), suffer from interventricular conductive defect and syncope; patients underwent EPS on admission time, and pacemaker implantation accordingly and programmed follow up for the device in the last four years. Our patients were 25 (59.5%) male and 17 (40.5%)female, all of them with syncope o
... Show Moremixtures of cyclohexane + n-decane and cyclohexane + 1-pentanol have been measured at 298.15, 308.15, 318.15, and 328.15 K over the whole mole fraction range. From these results, excess molar volumes, VE , have been calculated and fitted to the Flory equations. The VE values are negative and positive over the whole mole fraction range and at all temperatures. The excess refractive indices nE and excess viscosities ?E have been calculated from experimental refractive indices and viscosity measurements at different temperature and fitted to the mixing rules equations and Heric – Coursey equation respectively to predict theoretical refractive indices, we found good agreement between them for binary mixtures in this study. The variation of th
... Show MoreObjective This study aimed to evaluate the effects of disinfectant solutions, namely, the alcoholic extract of Salvadora persica L. (A1 = 10% and A2 = 15%) and chlorhexidine digluconate (A3 = 2%), on the tear strength and hardness of room temperature vulcanizing (RTV) VST50F and heat temperature vulcanizing (HTV) Cosmesil M511 silicone elastomers before and after reinforcement with nanofillers (TiO2) and intrinsic pigment. Materials and Methods: A total of 320 specimens were prepared, with 160 specimens each for RTV and HTV silicone. Forty specimens were evaluated before disinfection and divided into two equal groups, namely, control (without additive) and experimental (with ad
Biaxial hollow slab is a reinforced concrete slab system with a grid of internal spherical voids included to reduce the self-weight. This paper presents an experimental study of behavior of one-way prestressed concrete bubbled slabs. Twelve full-scale one-way concrete slabs of (3000mm) length with rectangular cross-sectional area of (460mm) width and (150mm) depth. Different parameters like type of specimen (solid or bubbled slabs), type of reinforcement (normal or prestress), range of PPR and diameter of plastic spheres (100 or 120mm) are considered. Due to the using of prestressing force in bubbled slabs (with ratio of plastic sphere diameter D to slab thickness H, D/H=0.67), the specimens showed an increase in ultimat
... Show MoreThis paper introduces experimental results of eighteen simply supported reinforced concrete beams of cross sections ( ) and length 3000 mm to study the effect of lacing reinforcement on the performance of such beams under static and fatigue loads. Twelve reinforced concrete beams (two of them are casted with vertical shear reinforcement used as control beams) are tested under four points bending loading with displacement control technique and six laced reinforced concrete beams were exposed to high frequency (10 Hz) by fixing the fatigue load in each cycle. Three parameters are used in the designed beams, which are: lacing bar diameter (4mm, 6mm, and 8mm), lacing bar inclination angle to horizontal , and lacing steel rat
... Show More