Preferred Language
Articles
/
alkej-837
A Study on the Effect of Multistage Toolpath in Fabricating a Customized Cranial Implant in Incremental Sheet Metal Forming
...Show More Authors

Incremental sheet forming (ISF) process offers a high degree of flexibility in the manufacturing of different sheet parts, which makes it an ideal candidate for prototype parts as well as efficient at fabricating various customized products at low production costs compared to traditionally used processes. However, parts produced in this process exhibit notable geometrical inaccuracy and considerable thickness reduction. In this paper, the single point incremental sheet forming variant of the process has been implemented to manufacture a highly customized cranial implant starting from the computed tomography (CT) scan data of the patient's anatomy. A methodology, from the modeling to the realization of the implant, is presented and discussed. The primary aim of the research was to analyze and study the effect of the multistage toolpath strategy compared to the traditional single-stage toolpath in terms of geometrical accuracy and thickness distribution. The final results show that the part formed in the multistage toolpath strategy exhibited a more uniform thickness distribution compared to the single-stage approach. Regarding the geometrical accuracy, the deviation analysis between the nominal and actual data has revealed that the multistage forming has significantly enhanced the final geometrical accuracy of the formed part.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 18 2017
Journal Name
Al-khwarizmi Engineering Journal
Fabrication and Characterization of Tri Metal Oxides by Chemical Spray Pyrolysis Technique as a Gas Sensor
...Show More Authors

In this research tri metal oxides were fabricated by simple chemical spray pyrolysis technique from (Sn(NO3)2.20 H2O, Zn(NO3)2.6 H2O, Cd(NO3)2.4 H2O) salts at concentration 0.1M with mixing weight ratio 50:50 were fabricated on silicon substrate n-type (111). (with & without the presence of grooves by the following diemensions (20μm width, 7.5μm depth) with thickness was about ( 0.1 ±0.05 µm) using water soluble as precursors at a substrate temperature 550 ºC±5, with spray distance (15 cm) and their gas sensing properties toward H2S gas at different concentrations (10,50,100,500 ppmv) in air were investigated at room te

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Feb 13 2018
Journal Name
Journal Of Optics
Solar selective performance of metal nitride/oxynitride based magnetron sputtered thin film coatings: a comprehensive review
...Show More Authors

View Publication
Scopus (35)
Crossref (26)
Scopus Clarivate Crossref
Publication Date
Fri Oct 01 2021
Journal Name
Applied Thermal Engineering
Simultaneous and consecutive charging and discharging of a PCM-based domestic air heater with metal foam
...Show More Authors

View Publication
Scopus (74)
Crossref (75)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Clinical And Experimental Dentistry
Preventive effect of combined Er, Cr: YSGG and fluoride gel on acid resistance of the permanent tooth enamel: An in vitro study
...Show More Authors

View Publication
Crossref (5)
Crossref
Publication Date
Mon Jan 15 2018
Journal Name
Pollution Research
STUDY THE EFFECT OF THE WAVES EMITTED FROM TOWERS COMMUNICATION IN SOME BIOLOGICAL STANDERDS FROM DIFFERENT REGIONS IN BAGHDAD
...Show More Authors

The mobile phone has become one of the most important in our days. The effects of waves from mobile base station may cause health effects on human. The aim of this work was to study the effect of radiofrequency (RF) emitted from mobile base station on the hemoglobin (Hb), packed cell (PCV), white blood cells (WBC) and liver enzymes activity including glutamic oxaloacetic transaminase (GOT), glutamic pyruvie transaminase (GPT) and Alkaline phosphatase (ALP). In this study the people divided into control group who living away from mobile base station and experimental group who living near to the mobile base station. The present result found there is no significant differences (P<0.05) in the Hb and PCV, but there was a significant increases (

... Show More
Publication Date
Fri Jul 15 2022
Journal Name
Bmc Health Services Research
Design and evaluation of a new mobile application to improve the management of minor ailments: a pilot study
...Show More Authors
Abstract<sec> <title>Background

Seeking pharmacist advice about minor ailments is a common practice among Iraqi patients because such advice is free and quick. Unfortunately, the assessment and management of minor ailments by Iraqi pharmacists were inappropriate. Therefore, this study aimed to develop a model for a mobile application that can assist community pharmacists in the diagnosis and management of minor ailments.

Methods

The scientific content of the application was based on the information in the symptoms in the pharmacy and British Nati

... Show More
Scopus (5)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
EFFECT OF USING STEVIA LEAF POWDER IN THE MANUFACTURE OF A DAIRY PRODUCT (CREAM) AGAINST THE MICROORGANISMS THAT CAUSE FOOD SPOILAGE AND THEIR ACCEPTANCE BY THE CONSUMER: EFFECT OF USING STEVIA LEAF POWDER IN THE MANUFACTURE OF A DAIRY PRODUCT (CREAM) AGAINST THE MICROORGANISMS THAT CAUSE FOOD SPOILAGE AND THEIR ACCEPTANCE BY THE CONSUMER
...Show More Authors

The increase in obesity and the many accompanying diseases is attributed to the increased production and consumption of foods made of non-nutritive sweeteners without regard to the risks of consuming additional calories, and this in turn leads to hormonal imbalance and metabolic disorders and the resulting imbalance and ill health that have spread to all segments of society. During the research, 0.01, 0.02, 0.03, 0.04 and 0.05 % of stevia sweetener was added to the cream instead of the sugar used. Physical and chemical tests were performed for the stevia extract and the microbial content in the cream, as well as the sensory evaluation. It was noted that fortifying the cream with calorie-free stevia sugar led to the production of

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 01 2015
Journal Name
International Journal Of Pharmacy And Pharmaceutical Sciences
Study the sustain release effect of different polymers used in the formulation of aspirin-rosuvastatin tablets
...Show More Authors

Scopus (5)
Scopus
Publication Date
Sun Jul 01 2007
Journal Name
Journal Of Faculty Of Medicine Baghdad
A Comparative Study of the Frequency of Occurrence of Genetic Skeletal Disorders in Iraq before and after the Second Gulf War, 1991
...Show More Authors

BACKGROUND: Genetic skeletal abnormalities are a heterogeneous group of genetic disorders frequently presenting with disproportionate short stature. AIM OF THE STUDY: To give an idea about the frequency of genetic skeletal abnormalities, and to find out whether these disorders are really increasing in the last 16 years or not. METHODS: During the period extending from (Jan, 1st 2003-April, 1st 2007), all cases of genetic skeletal disorders referred to the Genetic Counseling Clinic, Medical City – Baghdad who were born after 1991 were included in this study as the post-war group; the pre-war group, included all cases of skeletal disorders referred prior to 1991 (Jan., 1st 1987-Jan., 1st 1990). The demographic parameters, family history of

... Show More
Publication Date
Wed Sep 01 2021
Journal Name
Review Of International Geographical Education
A New Approach in Determining the Criteria of Equations for Morphometric Characteristics of River Basins - Applied Morphometric Study of The Mamaran Basin
...Show More Authors

This study aimed at some of the criteria used to determine the form of the river basins, and exposed the need to modify some of its limitations. In which, the generalization of the elongation and roundness ratio coefficient criterion was modified, which was set in a range between (0-1). This range goes beyond determining the form of the basin, which gives it an elongated or rounded feature, and the ratio has been modified by making it more detailed and accurate in giving the basin a specific form, not only a general characteristic. So, we reached a standard for each of the basins' forms regarding the results of the elongation and circularity ratios. Thus, circular is (1-0.8), and square is (between 0.8-0.6), the blade or oval form is (0.6-0

... Show More