Preferred Language
Articles
/
alkej-475
Heat Transfer of Single and Binary Systems in Pool Boiling
...Show More Authors

The present research focuses on the study of the effect of mass transfer resistance on the rate of heat transfer in pool boiling. The nucleate pool boiling heat transfer coefficients for binary mixtures (ethanol-n-butanol, acetone-n-butanol, acetone-ethanol, hexane-benzene, hexane-heptane, and methanol-water) were measured at different concentrations of the more volatile components. The systems chosen covered a wide range of mixture behaviors.

The experimental set up for the present investigation includes electric heating element submerged in the test liquid mounted vertically. Thermocouple and a digital indictor measured the temperature of the heater surface. The actual heat transfer rate being obtained by multiplying the voltmeter and ammeter readings. A water cooled coil condenses the vapor produced by the heat input and the liquid formed returns to the cylinder for re-evaporation.

The boiling results show that the nucleate pool boiling heat transfer coefficients of binary mixtures were always lower than the pure components nucleate pool boiling heat transfer coefficients. This confirmed that the mass transfer resistance to the movement of the more volatile component was responsible for decrease in heat transfer and that the maximum deterioration that was observed at a point was the absolute concentration differences between vapor and liquid phases at their maximum. All the data points were tested with the most widely known correlations namely those of Calus-Leonidopoulos, Fujita and Thome. It was found that Thome's correlation is the more representative form, for it gave the least mean and standard deviations.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
International Journal Of Surgery Open
Effectiveness of conservative management of uncomplicated acute appendicitis: A single hospital based prospective study
...Show More Authors
<bold>ABSTRACT</bold> <sec> <title>Background:

Acute appendicitis is one of the commonest causes of acute abdomen. There is a wide discussion and controversy on the surgical and nonsurgical treatment of acute uncomplicated appendicitis. The aim of this study was to evaluate the efficacy and outcomes of the conservative management of selected cases of acute appendicitis with an antibiotic first plan.

Patients and methods:

This was a single hospital-based prospective study with a durat

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Mon Mar 27 2017
Journal Name
Optical And Quantum Electronics
Photocurrent enhancement of heat treated CdSe-sensitized titania nanotube photoelectrode
...Show More Authors

View Publication
Scopus (14)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Performance Estimation of Heat Exchanger Operates By Evaporative Cooling Manner
...Show More Authors

        In this study the design and installation of evaporative air cooler was carried out using completely outdoor air (fresh air) according to two stage evaporative cooling principle. The laboratory equipment was installed by designing and manufacturing a cross flow plate heat exchanger, where aluminum plates used for this purpose with dimensions (50 × 30 × 40 cm). The surfaces of heat exchanger were covered by sawdust from wetted channels side, to increase the percentage of wetting these surfaces and hence improve the performance and efficiency of air cooler.

        An experimental study was carried out to estimate the performance of cooling system, where som

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance Evaluation of Three Phase Spray Direct Contact Heat Exchanger
...Show More Authors

 

The present investigation deals with experimental study of three-phase direct-contact heat exchanger, for water-Freon R11 system, where water is the continuous phase (liquid) and Freon R11 (liquid-gas) is the dispersed phase. The test section consisted of a cylindrical Perspex column with inner diameter 8cm and 1.2m long, in which, water was to be confined. Liquid Freon R11 drops were injected into the hot water filled column, through a special design of distributors at the bottom of the column. The liquid Freon R11 drops rose on their way up and evaporated into two-phase bubbles at atmospheric pressure. The study was devoted to express the effect of process variables such as c

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Journal Of Engineering
Thermal Performance Analysis of Compact Heat Exchangers for Thermoelectric Generators
...Show More Authors

The efficiency of internal combustion engines (ICE) is usually about thirty percent of the total energy of the fuel. The residual energy is lost in the exhaust gas, the lubrication, and the cooling water in the radiators. Recently much of the researcher’s efforts have focused on taking advantage of wasted energy of the exhaust gas. Using a thermoelectric generator (TEG) is one of the promising ways. However, TEG depends entirely on the temperature difference, which may be offered by the exhaust muffler. An experimental test has been conducted to study the thermal performance of a different muffler internal design. The researchers resort to the use of lost energy in an ICE using TEG, which is one of the ways to take adv

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Feb 01 2015
Journal Name
Journal Of Economics And Administrative Sciences
The possibility of applying CAPP technology to improve the quality of the product
...Show More Authors

     The research deals with A very important two subjects, computer aided process planning (CAPP) and Quality of product with its dimintions which identified by the producer organization, the goal of the research is to Highlight and know the role of the CAPP technology to improve quality of the product of (rotor) in the engines factory in the general company for electrical industries, The research depends case study style by the direct visits of researcher to the work location to apply the operational paths generated by specialized computer program designed by researcher, and research divides into four axes, the first regard to the general structure of the research, the second to the theoretical review, the t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 04 2022
Journal Name
Trends In Sciences
Asymptotic Stability of 3D Stochastic Positive Linear Systems with Delays
...Show More Authors

The article emphasizes that 3D stochastic positive linear system with delays is asymptotically stable and depends on the sum of the system matrices and at the same time independent on the values and numbers of the delays. Moreover, the asymptotic stability test of this system with delays can be abridged to the check of its corresponding 2D stochastic positive linear systems without delays. Many theorems were applied to prove that asymptotic stability for 3D stochastic positive linear systems with delays are equivalent to 2D stochastic positive linear systems without delays. The efficiency of the given methods is illustrated on some numerical examples. HIGHLIGHTS Various theorems were applied to prove the asymptoti

... Show More
View Publication
Scopus Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Liquid-Liquid Extraction of Metal Ions Using Aqueous Biphasic Systems
...Show More Authors

An investigation was conducted for the study of extraction of metal ions using aqueous biphasic systems. The extraction of iron, zinc and copper from aqueous sulphate media at different kinds of extractants SCN− , Cl- and I- , different values of pH of the feed solution, phase ratio, concentration of metals, concentration of extractant, concentration of polymer, and concentration of salt was investigated. Atomic absorption spectrophotometer was used to measure the concentration of iron, zinc and copper in the aqueous phase throughout the experiments. The results of the extraction experiments showed the use of SCN− as extractant, pH=2.5, phase ratio=1.5, concentration of metals 1g/l, concentration of extractant 0.06 %, concentration o

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jun 30 2021
Journal Name
Journal Of Economics And Administrative Sciences
Aggregation of Accounting information between differentiated accounting systems ( Case Study )
...Show More Authors

The purpose of the research is to present a proposed accounting system model for converting and aggregating accounting information within the framework of the differentiated accounting systems, and the research methodology consists of: The research problem is the existence of differentiated and dispersed accounting systems that operate within governmental economic units and at the same time seek to achieve a unified vision and goals for the organization, and the central research hypothesis is the possibility of conducting the process of conversion accounting information from the government accounting system to the unified accounting system, and then aggregate those systems. The research was conducted at the College of Administrat

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Mar 01 2018
Journal Name
Journal Of Engineering
Flexible Genetic Algorithm Based Optimal Power Flow of Power Systems
...Show More Authors

Nowadays, the power plant is changing the power industry from a centralized and vertically integrated form into regional, competitive and functionally separate units. This is done with the future aims of increasing efficiency by better management and better employment of existing equipment and lower price of electricity to all types of customers while retaining a reliable system. This research is aimed to solve the optimal power flow (OPF) problem. The OPF is used to minimize the total generations fuel cost function. Optimal power flow may be single objective or multi objective function. In this thesis, an attempt is made to minimize the objective function with keeping the voltages magnitudes of all load buses, real outp

... Show More
View Publication Preview PDF
Crossref