Comparison of Practical Investigations for CO Emissions Emitted From Single Cylinder S. I. Engine Fueled With Different Kinds of Hydrocarbon Fuels and Hydrogen
...Show More Authors

Liquefied petroleum gas (LPG), Natural gas (NG) and hydrogen were all used to operate spark ignition internal combustion engine Ricardo E6. A comparison of CO emissions emitted from each case, with emissions emitted from engine fueled with gasoline as a fuel is conducted.

The study was accomplished when engine operated at HUCR for gasoline n(8:1), was compared with its operation at HUCR for each fuel. Compression ratio, equivalence ratio and spark timing were studied at constant speed 1500 rpm.

CO concentrations were little at lean ratios; it appeared to be effected a little with equivalence ratio in this side, at rich side its values became higher, and it appeared to be effected by equivalence ratio highly, the results showed that CO emissions resulted from gasoline engine were higher than that resulted from using LPG and NG all the time; while hydrogen engine emitted extremely low CO concentrations.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 30 2021
Journal Name
College Of Islamic Sciences
Title of Thesis The creedal purposes deduced from the Almighty’s saying: {It is easy for me}
...Show More Authors

 Summary

    I wanted to address this topic because of creedal purposes importance,and its r le in regulating lives of individuals and society, and to talk about purposes of Almighty's saying:{It is easy for me},to simplify its meanings for general educated person to obtain the believe of the Creator’s power and his oneness.

Therefore,this research came,whichincludes:an introduction and topics, first :concept of creedal objectives and their divisions,second: creedal purposes in Almighty’s saying:{It is easy for me},and conclusion:in where most important results were included:

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 17 2017
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
10.28936 STUDY OF THE KINETIC AND ADSORPTION ISOTHERM PARAMETERS FOR REMOVING COPPER AND IRON IONS FROM AQUEOUS SOLUTIONS BY USING AGRICALTURAL BY-PRODUCTS.: STUDY OF THE KINETIC AND ADSORPTION ISOTHERM PARAMETERS FOR REMOVING COPPER AND IRON IONS FROM AQUEOUS SOLUTIONS BY USING AGRICALTURAL BY-PRODUCTS.
...Show More Authors

Wheat straw was modified with malonic acid in order to get low cost adsorbent have a good ability to remove copper and ferric ions from aqueous solutions, chemical modification temperature was 120°C and the time was 12 h. Parameters that affect the adsorption experiments were studied and found the optimum pH were 6 and 5 for copper and iron respectively and the time interval was 120 min and the adsorbent mass was 0.1 g. The values for adsorption isotherms parameters were determined according to Langmuir [qmax were 54.64 and 61.7 mg/g while b values were 0.234 and 0.22 mg/l] , Freundlich [Kf were 16.07 and 18.89 mg/g and n were 2.77 and 3.16], Temkin [B were 0.063 and 0.074 j/mol and At were 0.143 and 1.658 l/g] and for Dubinin-Radushkev

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 01 2025
Journal Name
Pharmaceutical Nanotechnology
Preparation, <i>In-vitro, Ex-vivo</i>, and Pharmacokinetic Study of Lasmiditan as Intranasal Nanoemulsion-based <i>In Situ</i> Gel
...Show More Authors
Background:

Lasmiditan (LAS) is a recently developed antimigraine drug and was approved in October, 2019 for the treatment of acute migraines; however, it suffers from low oral bioavailability, which is around 40%.

Objective:

This study aimed to improve the LAS bioavailability via formulation as nanoemulsionbased in situ gel (NEIG) given intranasally and then compare the traditional aqueous-LASsuspension (AQS) with the two successful intranasal prepared formulations (NEIG 2 and NEIG 5) in order to determine its relative bioavailability (F-relative) via using rabbits.

Method:
... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Effects of Laser Energy on n-Ge/p-SnS Hetrojunction Diode Detector in Different Environments
...Show More Authors

In the present work, heterojunction diode detectors will be prepared using germanium wafers as a substrate material and 200 nm tin sulfide thickness will be evaporated by using thermal evaporation method as thin film on the substrate. Nd:YAG laser (λ=532 nm) with different energy densities (5.66 J/cm2 and 11.32 J/cm2) is used to diffuse the SnS inside the surface of the germanium samples with 10 laser shots in different environments (vacuum and distilled water). I-V characteristics in the dark illumination, C-V characteristics, transmission measurements, spectral responsivity and quantum efficiency were investigated at 300K. The C-V measurements have shown that the heterojunction were of abrupt type and the maximum value of build-in pot

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 05 2019
Journal Name
Journal Of The College Of Education For Women
Basic training requirements for teachers from the viewpoint of supervisors in Mafraq Governorate
...Show More Authors

This study aimed to reveal the stage for teachers of basic training needs from the perspective of workers in Mafraq Governorate, through a survey of a sample of counselors look at the Ajloun area schools reached (58) counselors.
To achieve the objective of the study was constructed questionnaire where they are finalized (18) items distributed on two dimensions (professional needs, performance requirements) and after confirmation of the validity and reliability have been applied to the sample where the results showed that training needs were high, both on a professional or per formative level .
The results also showed no statistically significant differences in the areas of tool due to gender, educational qualification. The study co

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 18 2017
Journal Name
Al-khwarizmi Engineering Journal
Fabrication of Carbon Nanotube Reinforced Al2O3/Cr2O3 Nanocomposites by Coprecipitation Process
...Show More Authors

In this research, the effect of multi-walled carbon nanotubes (MWCNTs) on the alumina/chromia (Al2O3/Cr2O3) nanocomposites has been investigated. Al2O3/Cr2O3-MWCNTs nanocomposites with variable contents of Cr2O3 and MWCNTs were fabricated using coprecipitation process and followed by spark plasma sintering. XRD analysis revealed a good crystallinity of sintered nanocomposites samples and there was only one phase presence of Al2O3-Cr2O3 solid solution. Density, Vickers microhardness, fracture toughness and fracture strength have been measured in the sintered samples. The results show tha

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Baghdad Science Journal
Synthesis, Spectroscopy of New Lanthanide Complexes with Schiff Base Derived From (4-Antipyrinecarboxaldehyde with Ethylene Di-Amine) and Study the Bioactivity
...Show More Authors

The study involved preparing a new compound by combining Schiff bases generated from compounds for antipyrine, including lanthanide ions (lanthanum, neodymium, erbium, gadolinium, and dysprosium). The preparation of the ligand from condensation reactions (4-antipyrinecarboxaldehyde with ethylene di-amine) at room temperature, and was characterization using spectroscopic and analytical studies ( FT-IR, UV-visible spectra, 1H-NMR, mass spectrometry, (C.H.N.O), thermogravimetric analysis (TGA), in addition to the magnetic susceptibility and conductivity measurement of the synthesis complexes, among the results we obtained from the tests, we showed that the ligand behaves with the (triple Valence) lanthanide ions, the multidentate

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (2)
Scopus Crossref
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Effect of plasma jet on the water and hydrogen peroxide that used for assisted teeth bleaching
...Show More Authors

In this work the interaction of plasma jet with water and hydrogen peroxide liquids used for assisted teeth bleaching by plasma jet had been study. A homemade plasma jet system was used. The plasma jet supply by 15 W electrical power generated by high voltage power supply of 9.6 kV peak to peak and frequency of 33 kHz .this power supply generate high electric field on electrodes that would be enough to ionize the argon gas. Some important agents were study such as the effect of the Ar gas flow rates on the length of the plasma jet, the influence of plasma jet on some properties of water and two hydrogen peroxide concentrations 25 % and 30 % like pH, conductivity and liquid temperature for different exposure time. The liquids temperature

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Apr 30 2020
Journal Name
Journal Of Economics And Administrative Sciences
Comparison Between Tree regression (TR), and Negative binomial regression (NBR) by Using Simulation.
...Show More Authors

            In this paper, the process of comparison between the tree regression model and the negative binomial regression. As these models included two types of statistical methods represented by the first type "non parameter statistic" which is the tree regression that aims to divide the data set into subgroups, and the second type is the "parameter statistic" of negative binomial regression, which is usually used when dealing with medical data, especially when dealing with large sample sizes. Comparison of these methods according to the average mean squares error (MSE) and using the simulation of the experiment and taking different sample

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
Comparison Some Parametric and Non –parametric Methods To Estimate Median Effective Dose ( ED5
...Show More Authors

            In this paper the research represents an attempt of expansion in using the parametric and non-parametric estimators to estimate the median effective dose ( ED50 ) in the quintal bioassay and comparing between  these methods . We have Chosen three estimators for Comparison. The first estimator is
( Spearman-Karber )  and the second estimator is ( Moving Average ) and The Third estimator  is ( Extreme Effective Dose ) .
We used a minimize Chi-square as a parametric method. We made a Comparison for these estimators by calculating the mean square error of (ED50) for each one of them and comparing it with the optimal the mean square

... Show More
View Publication Preview PDF
Crossref