Preferred Language
Articles
/
alkej-457
Using TermoDeck System for Pre-Cooling/ Heating to Control the Building Inside Conditions
...Show More Authors

In this paper, experimental study has been done for temperature distribution in space conditioned with Ventilation Hollow Core Slab (TermoDeck) system. The experiments were carried out on a model room with dimensions of (1m 1.2m 1m) that was built according to a suitable scale factor of (1/4). The temperature distributions was measured by 59 thermocouples fixed in several locations in the test room. Two cases were considered in this work,  the first one during unoccupied period at night time (without external load) and the other at day period with external load of 800W/m2 according to solar heat gain calculations during summer season in Iraq. All results confirm the use of TermoDeck system for ventilation and cooling/heating purposes in arid and hot climate for its ease, simple and good comfort performance and to save energy and improve the overall energy performance of the building by reducing the peak load.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 07 2009
Journal Name
Baghdad Science Journal
Effective Rules for Building and Securing of Blogs
...Show More Authors

Blogging is about more than just putting thoughts on a web; it's about connecting with and hearing from anyone who read the work. Many web sites now days help to get a free account to quick post thoughts and photos interact with people, and more. The fastest way to understand blogging is to try it out, but in that case securing the blog is important, by including authentication schemes. In this paper we suggest implications of our research for improving the design and usefulness of blogging systems, and also we divided the blogs depending on the subject and need, which are either to be used in public or only used by small group, so we can suggest different steps for securing the blogs.

View Publication Preview PDF
Crossref
Publication Date
Mon Apr 15 2019
Journal Name
Proceedings Of The International Conference On Information And Communication Technology
Optimal control of compliant planar robot for safe impact using steepest descent technique
...Show More Authors

View Publication
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Trajectory Tracking Control for a Wheeled Mobile Robot Using Fractional Order PIaDb Controller
...Show More Authors

Nowadays, Wheeled Mobile Robots (WMRs) have found many applications as industry, transportation, inspection, and other fields. Therefore, the trajectory tracking control of the nonholonomic wheeled mobile robots have an important problem. This work focus on the application of model-based on Fractional Order  PIaDb (FOPID) controller for trajectory tracking problem. The control algorithm based on the errors in postures of mobile robot which feed to FOPID controller to generate correction signals that transport to  torque for each driven wheel, and by means of dynamics model of mobile robot these torques used to compute the linear and angular speed to reach the desired pose. In this work a dynamics model of

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Baghdad Science Journal
Using Wild Plant Species Grown in Wadi Al – Tib Region North East of Al – Ammara, Iraq, as Indicators of Heavy Metals Accumulation
...Show More Authors

The current study included, studying the ability of eight genera of plants belong to Brassicaceae family, Brassica tournifortii, Cakile Arabica, Capsella bursa – pastoris,Carrichtera annua, Diplotaxis acris, Diplotaxis haru , Eruca sativa and Erucaria hispanica to accumulate ten heavy metals Cadmium, Chromium , Copper, Mercury, Manganese ,Nickel ,Lead ,and Zinc . Plant leaves samples were collected from Al-Tib area during spring of 2021.The data demonstrated that, the highest conc. of Cd was 2.7 mg/kg in Diplotaxis acris leaves and lower value was 0.3 mg/kg in Cakile Arabica leaves. For Co, the highest conc.was 1.3 mg/kg in Capsella bursa – pastoris leaves, whereas the lower value was 0.5 mg/kg in Cakile arabica leaves. As for Cr ele

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Theoretical Study of The Heating Effect of Laser Radiations on SiUcaGlass Systems
...Show More Authors

A theoretical study has been proposed to investigate the effects of different laser radiations (Nd - glass, DF and C02) as a heating source on different glass samples (Optical glass, Bk - 7 and Soda - lime glass) and different waves lengths (10.6, 3.8, 1.6) ???. The heat changes as which are resulted due irradiation with laser sources have been determined by using the one dimension mathematical relation as a function of time (t) and depth (z). The results of the study show ed that the irradiation with C02 laser had a greater effect than DF laser, while the effects of Nd - glass laser were minimal with a power density of (1.8*10?? w/m2) within atime(l^sec).(Forboth Kinds) The change in the temperatures were not exceeded than (70"K) in all sa

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Zinc Element Traces to Inhibit Scale Formation on Cooling Tower and Air Cooler Systems
...Show More Authors

Calcium carbonate is predominantly present in aqueous systems, which is
commonly used in industrial processes. It has inverse solubility characteristics
resulting in the deposition of scale on heat transfer surface. This paper focuses on
developing methods for inhibition of calcium carbonate scale formation in cooling
tower and air cooler system where scaling can cause serious problems, ZnCl 2 and ZnI
2 has been investigated as scale inhibitor on AISI 316 and 304. ZnCl 2 were more
effective than ZnI 2 in both systems, and AISI 316 show more receptivity to the
chlorides salt compared to AISI 304. The inhibitors were more effective in cooling
tower than air cooler system. AISI 316 show more constant inhibition effic

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 13 2017
Journal Name
Al-khwarizmi Engineering Journal
Energy and Exergy Analysis on Modified Closed Wet Cooling Tower in Iraq
...Show More Authors

The present study involves experimental analysis of the modified Closed Wet Cooling Tower (CWCT) based on first and second law of thermodynamics, to gain a deeper knowledge in this important field of engineering in Iraq. For this purpose, a prototype of CWCT optimized by added packing under a heat exchanger was designed, manufactured and tested for cooling capacity of 9 kW. Experiments are conducted to explore the effects of various operational and conformational parameters on the towers thermal performance. In the test section, spray water temperature and both dry bulb temperature and relative humidity of air measured at intermediate points of the heat exchanger and packing. Exergy of water and air were calculated by applying the exergy

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
An Approximate solution for two points oundary value problem corresponding to some optimal control
...Show More Authors

this paper presents a novel method for solving nonlinear optimal conrol problems of regular type via its equivalent two points boundary value problems using the non-classical

View Publication Preview PDF
Publication Date
Sun Sep 30 2012
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Control of Non Isothermal CSTR Using Different Controller Strategies
...Show More Authors

In all process industries, the process variables like flow, pressure, level, concentration
and temperature are the main parameters that need to be controlled in both set point
and load changes.
A control system of propylene glycol production in a non isothermal (CSTR) was
developed in this work where the dynamic and control system based on basic mass
and energy balance were carried out.
Inlet concentration and temperature are the two disturbances, while the inlet
volumetric flow rate and the coolant temperature are the two manipulations. The
objective is to maintain constant temperature and concentration within the CSTR.
A dynamic model for non isothermal CSTR is described by a first order plus dead
time (FO

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 14 2023
Journal Name
Journal Of Educational And Psychological Researches
Comparative Study in Attitudes towards the Covid-19 Vaccine According to Locus of Control (Internal - External) of University Students
...Show More Authors

Abstract

The current research aims to identify the attitudes towards the Covid-19 vaccine and the Locus of Control (internal, external) among university students, to identify the significance of the difference in attitudes towards the Covid-19 vaccine, the significance of the difference in the Locus of Control (internal, external) according to the gender variable (male, female), and to identify the significance of the difference in students’ attitudes towards Covid-19 vaccine according to the Locus of Control (internal, external). To achieve the objective of the research, the researcher developed two scales, a scale of (20) items to identify the attitudes toward a covid-19 vaccine, and a scale of the locus of c

... Show More
View Publication Preview PDF