The diabetic foot is considered one of the long term diabetes complications caused by a defect in blood vessel and nerve system. This requires dealing with diabetic foot with professional medical care, so as to prevent its development in advanced stages which could end to gangrene and amputation of the foot. This study has been initiated through follow-up of twelve patients with diabetes and the presence various occlusions in lower limb artery. One patient from them was chosen for investigation, this patient has stenosis in popliteal artery and presence multiple stenosis in superficial femoral artery. This study based on analysis present case of patient and prediction for progress stenosis in superficial femoral artery till arrive semi total occlusion of the artery and interpret the occurrence of gangrene in the lower limb. The geometrical values of the artery and stenosis were acquired measured directly from the patient by using angiography device. The disease of gangrene and artery stenosis in diabetic foot has been investigated by using a simulation program (ANSYS Fluent CFD). The results of study by using four models with (75%, 90%) stenosis from original artery diameter in the healthy patient case are presented and compared with present and healthy case (without stenosis). It has been appeared, with presence of multi stenosis in superficial femoral artery for diabetic foot, and by assuming the blood to be a Newtonian fluid, a significant increase in the blood velocity and wall shear stress in the area of stenosis compared with non stenosis region. The blood flow rate was decreased constrained as the degree of stenosis increased and vice versa. Peak blood velocity is about (0.88) m/sec for healthy artery, it reaches (2) m/sec for a 42.4% stenosis (current case).The maximum velocity values were (10.36, 49.31) m/sec for 75%, 90% stenosis respectively. The maximum wall shear stress at the stenosis region varies from (1094) pa in the 75% stenosis to (15916) pa in the 90% stenosis against a values of (6.36, 380.5) pa in the healthy artery, current case respectively.
Polycystic ovary syndrome (PCOS) is the main cause of female infertility. The role of insulin resistance in the development of polycystic ovary is actively discussed here. The study included patients with PCOS without insulin resistance (n = 48) and with insulin resistance (n = 39). The comparison groups were patients with no history of PCOS: a control group without insulin resistance (n = 46) and a group of patients with insulin resistance (n = 45). The following parameters were determined in patients: FSH, LH, TSH, T3f, T4f, PRL, E2, 17-OHd, Pr, AMH, Test total, Testf, DHEAS, DHEASs, SHBG, ACTH, cortisol, IRI, IGF-1, C-peptide, and glucose level. The HOMA-IR index and the LH / FSH ratio and t
... Show MoreThis work involves separating and studying the aminoacylase-1 (ACY1) of amniotic fluid from healthy pregnant, mainly one peak with higher activity has been isolated by DEAE-Cellulose ion exchange from the proteinous supernatant produced by deposition of proteins using ammonium sulfate (65%) after dialysis. The purification folds reaching to 19 folds also gave one protein peak when injected into the gel filtration column, a high ACY1 purity was obtained, with 38 folds of purification. It was found that the molecular weight of the isolated ACY1 was up to 46698 Dalton when using gel chromatography technique.The effect of ACY1 isolate was studied on rats with oxidative stress caused by lead acetate(LA) at 40 mg / kg body weight and compare
... Show MoreAn experimental study was conducted on pressure drop of water flow through vertical cylindrical packed beds in turbulent region and the influence of the operating parameters on its behavior. The bed packing was made of spherical and non-spherical particles (spheres, Rasching rings and intalox saddle) with aspect ratio range 3.46 D/dp 8.486 obtaining bed porosities 0.396 0.84 and Reynolds number 1217 21758. The system is consisted of 5 cm inside diameter Perspex column, 50 cm long; distilled water was pumped through the bed with flow rate 875, 1000, 1125, 1250,1375 and 1500 l/h and inlet water temperature 20, 30, 40 and 50 ˚C. The packed bed system was monitored by using LabVIEW program, were the result
... Show MoreObjectives: The study aims to evaluate patients’ performance toward insulin injection after training program to
identify the variation in skill of patients in insulin injection technique with regard to some variable (i.e.
educational level and duration of insulin injection.
Methodology: A quasi experimental study has been conducted on diabetic patients.
An observational checklist had been prepared which consisted of 4 main areas with 37 sub-items, which are
syringe preparation for injection, insulin drawing; skin preparation for injection and insulin injection. Each of the
sub-items has 2 options yes or no. One score for positive answer and zero for no.
The sample of the study consisted of (n =30) males and females
This study was designed to investigate the hypoglycemic and hypolipidemic activity of aqueous green tea (GT) extract in normal and alloxan-induced diabetic rats. Forty adult male albino rats weighing 180-200 g were divided into four groups of 10 rats each: The first group was served as control; the second group was treated with GT (250 mg/kg b.w); the third group was affected by inducing experimental diabetes by intraperitonial injection of alloxan (150 mg/kg b.w); and the fourth group was affected by inducing diabetes and treated with GT (250 mg/kg b.w). Level of blood glucose and lipid profile [total cholesterol (TC), triglycerides (TG), high-density lipoprotein cholesterol (HDL-C), low density lipoprotein cholesterol (LDL-C) and ve
... Show MoreCantilever beams are used in many crucial applications in machinery and construction. For example, the airplane wing, the microscopic probe for atomic force measurement, the tower crane overhang and twin overhang folding bridge are typical examples of cantilever beams. The current research aims to develop an analytical solution for the free vibration problem of cantilever beams. The dynamic response of AISI 304 beam represented by the natural frequencies was determined under different working surrounding temperatures ((-100 ℃ to 400 ℃)). A Matlab code was developed to achieve the analytical solution results, considering the effect of some beam geometrical dimensions. The developed analytical solution has been verified successful
... Show MoreCantilever beams are used in many crucial applications in machinery and construction. For example, the airplane wing, the microscopic probe for atomic force measurement, the tower crane overhang and twin overhang folding bridge are typical examples of cantilever beams. The current research aims to develop an analytical solution for the free vibration problem of cantilever beams. The dynamic response of AISI 304 beam represented by the natural frequencies was determined under different working surrounding temperatures ((-100 ℃ to 400 ℃)). A Matlab code was developed to achieve the analytical solution results, considering the effect of some beam geometrical dimensions. The developed analytical solution has been verified successfully wi
... Show MoreThe art of preventing the detection of hidden information messages is the way that steganography work. Several algorithms have been proposed for steganographic techniques. A major portion of these algorithms is specified for image steganography because the image has a high level of redundancy. This paper proposed an image steganography technique using a dynamic threshold produced by the discrete cosine coefficient. After dividing the green and blue channel of the cover image into 1*3-pixel blocks, check if any bits of green channel block less or equal to threshold then start to store the secret bits in blue channel block, and to increase the security not all bits in the chosen block used to store the secret bits. Firstly, store in the cente
... Show More