In this work, laboratory experiments were carried out to verify direct contact membrane distillation system’s performance in highly saline water desalination. The study included the investigation of various operating conditions, like feed flow rate, temperature and concentration of NaCl solution and their impact on the permeation flux were discussed. 16 cm2 of a flat sheet membrane module with commercial poly-tetra-fluoroethylene (PTFE) membrane, which has 0.22 μm pore size, 96 µm thickness and 78% average porosity, was used. A high salt rejection factor was obtained greater than 99.9%, and the permeation flux up to 17.27 kg/m2.h was achieved at 65°C for hot feed side and 20°C for cold side stream.
The present work aims to improve the flux of forward osmosis with the use of Thin Film Composite membrane by reducing the effect of polarization on draw solution (brine solution) side.This study was conducted in two parts. The first is under the effect of polarization in which the flux and the water permeability coefficient (A) were calculated. In the second part of the study the experiments were repeated using a circulating pump at various speeds to make turbulence and reduce the effect of polarization on the brine solution side.
A model capable of predicting water permeability coefficient has been derived, and this is given by the following equations:
Z=Z0 +C.R.T/9.8(d2/D2+1) [Exp. [-9.8(d
The purpose of research is highlighting the role of tax expenses in promoting direct foreign investment in Iraq, The main objective of the increase in the field of tax expenses is to manage the competition in the production of goods and services locally, in addition to the various qualities of the economical. As the search contributes to the idea of the role of the policy of the tax expenses in the promotion of foreign companies operating in Iraq. The analytical and transparent transparency used by adoption of cases of the relevant body of the tax body. For each image or form of tax expenses have been reliably related to the promotion of direct foreign investment, the taxpayers highlighted the annual controls, tax cuts as the sample was
... Show MoreThe increasing drinking water demand in many countries leads to an increase in the use of desalination plants, which are considered a great solution for water treatment processes. Reverse osmosis (RO) and electro-dialysis (ED) systems are the most popular membrane processes used to desalinate water at high salinity. Both systems work by separating the ionic contaminates and disposing of them as a brine solution, but ED uses electrical current as a driving force while RO uses osmotic pressure. A direct comparison of reverse osmosis and electro-dialysis systems is needed to highlight process development similarities and variances. This work aims to provide an overview of previous studies on reverse osmosis and electro-dial
... Show More:
While practicing of International business particularly that centered on foreign direct investment, let on one side, to achieving objectives of transnational corporations specially that represented in continuous pursue to improving its cash flows and maximization of stockholders wealth which is considered the most important objective to the transnational corporations, but in the same time its lead, on other side, to increasing the foreign exchange risk exposuring these corporations. So, the transnational corporations (TNCs) struggling to make strategies which are dealing in smart way, with this risk and its management in way that enable to avoiding risk comple
... Show MoreDeveloping countries have depended since long time on the developed countries to increase the levels of development and improving rates of growth direction to the best way where taking this dependence many shapes influenced by the evolution form of international relations and this dependence shows how the great deficiencies in sources of local financing, which called developing countries to increase their reliance on external funding sources, represented in the form of grants, subsidies, loans and foreign investment, pursuing States in that the application of economic reform policies in pursuit of faster economic growth and restructure its economy and achieve economic stability. In the early eighties of the last
... Show Moreالاستثمار الاجنبي المباشر في العراق ودوره في تحقيق التنمية الاقتصادية
Thin films of Magnetite have been deposited on Galvanized Steel (G-S) alloy using RF-reactive magnetron sputtering technique and protection efficiency of the corrosion of G-S. A Three-Electrodes Cell was used in saline water (3.5 % NaCl) solution at different temperatures (298, 308, 318 & 328K) using potentiostatic techniques with. Electrochemical Impedance Spectroscopy (EIS) and fitting impedance data via Frequency Response Analysis (FRA) were applied to G-S alloy with Fe3O4 and tested in 3.5 % NaCl solution at 298K.Results taken from Nyquist and Bode plots were analyzed using software provided with the instrument. The results obtained show that the rate of corrosion of G.S alloy increased with increasing the temperatures from 298 t
... Show MoreIn the present study, the removal of zinc from synthetic waste water using emulsion liquid membrane extraction technique was investigated. Synthetic surfactant solution is used as the emulsifying agent. Diphenylthiocarbazon (ditizone) was used as the extracting agent dissolved in carbon tetrachloride as the organic solvent and sulfuric acid is used as the stripping agent. The parameters that influence the extraction percentage of Zn+2 were studied. These are the ratio of volume of organic solvent to volume of aqueous feed (0.5-4), ratio of volume of surfactant solution to volume of aqueous feed (0.2-1.6), pH of the aqueous feed solution (5-10), mixing intensity (100-1000) rpm, concentration of extracting agent (20-400) ppm, surfactant co
... Show MoreDirect field-orientation Control (DFOC) of induction motor drives without mechanical speed sensors at the motor shaft has the attractions of low cost and high reliability. To replace the sensor, information on the rotor speed and position are extracted from measured stator currents and from voltages at motor terminals. In this paper presents direct field-orientation control (DFOC) with two type of kalman filter (complete order and reduced order extended kalman filter) to estimate flux, speed, torque and position. Simulated results show how good performance for reduced order extended kalman filter over that of complete order extended kalman filter in tracking performance and reduced time of state estimation.