Preferred Language
Articles
/
alkej-328
Fabrication and Characterization of Tri Metal Oxides by Chemical Spray Pyrolysis Technique as a Gas Sensor
...Show More Authors

In this research tri metal oxides were fabricated by simple chemical spray pyrolysis technique from (Sn(NO3)2.20 H2O, Zn(NO3)2.6 H2O, Cd(NO3)2.4 H2O) salts at concentration 0.1M with mixing weight ratio 50:50 were fabricated on silicon substrate n-type (111). (with & without the presence of grooves by the following diemensions (20μm width, 7.5μm depth) with thickness was about ( 0.1 ±0.05 µm) using water soluble as precursors at a substrate temperature 550 ºC±5, with spray distance (15 cm) and their gas sensing properties toward H2S gas at different concentrations (10,50,100,500 ppmv) in air were investigated at room temperature which related with the petroleum industry. Furthermore structural and morphology properties were inspecting. Experimental results show that the Zn2SnO4 and Cd2SnO4 thin films were achieved from the used salts and samples gas sensitivity which improved with the presence of substrate grooves. Which make the sensor suitable for the detection of lower .concentrations of hazard H2S gas in the petroleum industry.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu May 11 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Annealing Temperature on the Structural and Optical Properties of The CdO Thin Films Prepared By Vacuum Evaporation Thermal Technique
...Show More Authors

      Cadmium Oxide films have been prepared by vacuum evaporation technique on a glass substrate at room temperature. Structural and optical properties of the films are studied at different annealing temperatures (375 and 475) ËšC, for the thickness (450) nm at one hour. The crystal structure of the samples was studied by X- ray diffraction. The highest value of the absorbance is equal to (78%) in the wavelength (530) nm, at annealing temperature (375) ËšC. The value of at a rate of deposition is (10) nm/s. The value of optical energy gap found is equal to (2.22) eV.

View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Indonesian Journal Of Electrical Engineering And Computer Science
Lightweight route adjustment strategy for mobile sink wireless sensor networks
...Show More Authors

<span>As a result of numerous applications and low installation costs, wireless sensor networks (WSNs) have expanded excessively. The main concern in the WSN environment is to lower energy consumption amidst nodes while preserving an acceptable level of service quality. Using multi-mobile sinks to reduce the nodes' energy consumption have been considered as an efficient strategy. In such networks, the dynamic network topology created by the sinks mobility makes it a challenging task to deliver the data to the sinks. Thus, in order to provide efficient data dissemination, the sensor nodes will have to readjust the routes to the current position of the mobile sinks. The route re-adjustment process could result in a significant m

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sun Oct 21 2018
Journal Name
Journal Of Planner And Development
توظيف العمارة المعاصرة في التقليل من الاحتباس الحراري
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Sep 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Treatment of Wastewater of Alcohol Factory by Filtration as Primary Treatment
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Jun 03 2019
Journal Name
Al-kindy College Medical Journal
A Case Report -Bilateral Giant Achilles Tendon Xanthomas Resection with a Tendon transverse Technique
...Show More Authors

Background : Xanthomatosis is a disease in which large tendon tumors can occur, especially in the Achilles tendon. This disease is a rare interesting orthopaedic condition. Case Report:A case of a twenty eight year old girl patient with giant bilateral Achilles tendon xanthomas in which both tumors were resected. There was no ulceration on the both sides. The patient was treated by total resection of the lesion and reconstruction using tendon transfer of the Peroneus brevis and Flexor hallusis longus. Postoperative treatment consisted of six weeks lower leg cast immobilization followed by partial weight bearing. After 4 months the patient was able to walk pain free without any difficulties. It has been suggested that total resection with au

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 12 2019
Journal Name
Al-kindy College Medical Journal
A Case Report -Bilateral Giant Achilles Tendon Xanthomas Resection with a Tendon transverse Technique
...Show More Authors

Background : Xanthomatosis is a disease in which large tendon tumors can occur, especially in the Achilles tendon. This disease is a rare interesting orthopaedic condition.

Case Report:A case of a twenty eight year old girl patient with giant bilateral Achilles tendon xanthomas in which both tumors were resected.

There was no ulceration on the both sides. The patient was treated by total resection of the lesion and reconstruction using tendon transfer of the Peroneus brevis and Flexor hallusis longus. Postoperative treatment consisted of six weeks lower leg cast immobilization followed by partial weight bearing. After 4 months the patient was able to walk pain free without any difficultie

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Aug 30 2023
Journal Name
Al-kindy College Medical Journal
‘Peacock tail’ Clipping Technique for a Giant Middle Cerebral Artery Aneurysm: A Technical Note
...Show More Authors

Background: Giant middle cerebral artery (MCA) aneurysms are surgically challenging lesions. Because of the complexity and variability of these aneurysms, a customized surgical technique is often needed for each case. In this article, we present a modified clip reconstruction technique of a ruptured complex giant partially thrombosed middle cerebral artery aneurysm.

Case description: The aneurysm was exposed using the pterional approach. Following proximal control, the aneurysm sac was decompressed. Then, we applied permanent clips to reconstruct the aneurysm neck. The configuration of the aneurysm mandated a tailored clipping pattern to account for resi

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri May 01 2015
Journal Name
Journal Of Engineering
On Gradient Descent Localization in 3-D Wireless Sensor Networks
...Show More Authors

Localization is an essential demand in wireless sensor networks (WSNs). It relies on several types of measurements. This paper focuses on positioning in 3-D space using time-of-arrival- (TOA-) based distance measurements between the target node and a number of anchor nodes. Central localization is assumed and either RF, acoustic or UWB signals are used for distance measurements. This problem is treated by using iterative gradient descent (GD), and an iterative GD-based algorithm for localization of moving sensors in a WSN has been proposed. To localize a node in 3-D space, at least four anchors are needed. In this work, however, five anchors are used to get better accuracy. In GD localization of a moving sensor, the algo

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 30 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
SYNTHESIS OF NEW LEVOFLOXACIN SELECTIVE MEMBRANE SENSOR BASED ON MOLECULARLY IMPRINTED POLYMERS.: SYNTHESIS OF NEW LEVOFLOXACIN SELECTIVE MEMBRANE SENSOR BASED ON MOLECULARLY IMPRINTED POLYMERS.
...Show More Authors

Two molecular imprinted polymer (MIP) membranes for Levofloxacin (LEV) were prepared based on PVC matrix. The imprinted polymers were prepared by polymerization of styrene (STY) as monomer, N,N methylene di acrylamide as a cross linker ,benzoyl peroxide (BPO) as an initiator and levofloxacin as a template. Di methyl adepate (DMA) and acetophenone (AOPH) were used as plasticizers , the molecular imprinted membranes and the non molecular imprinted membranes were prepared.  The slopes and detection limits of the liquid electrodes ranged from -21.96 – -19.38 mV/decade and 2×10-4M- 4×10-4M, and Its response time was around 1 minute, respectively. The liquid  electrodes were packed with 0.1 M standar

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
Al-wakidi as a documentary historian
...Show More Authors

This research is about the resources and the way of al-Waqidi in his
researching of al-sira of the Prophet. And what happened in the first of Islam.
This research is about the documents which al-Waqidi had it. Some of it,
which he had visited, was the places, especially the periods which the events had took
place in. He was asking those whom were contemporary to the happenings, from the
sons of al-Sahaba and al-Tabi’een.
Also this research is lightening on the new studies that gave this historian a
good respect during his work, in which he could gave the reality about his authorship.
The research is trying to draw real way of al-Waqidi and what were reported by him,
especially the documents, and what he had s

... Show More
View Publication Preview PDF