In this research a recent developed practical modeling technique is applied for the glucose regulation system identification. By using this technique a set of mathematical models is obtained instead of single one to compensate for the loss of information caused by the optimization technique in curve fitting algorithms, the diversity of members inside the single set is interpreted in term of restricted range of its parameters, also a diagnosis criteria is developed for detecting any disorder in the glucose regulation system by investigating the influence of variation of the parameters on the response of the system, this technique is applied in this research practically for 20 cases with association of National Center for Diabetes / Al Mustanseryia University.
Project management are still depending on manual exchange of information based on paper documents. Where design drawings drafting by computer-aided design (CAD), but the data needed by project management software can not be extracted directly from CAD, and must be manually entered by the user. The process of calculation and collection of information from drawings and enter in the project management software needs effort and time with the possibility of errors in the transfer and enter of information. This research presents an integrated computer system for building projects where the extraction and import quantities, through the interpretation of AutoCAD drawing with MS Access database of unit costs and productivities for the pricing and
... Show Moreملخص الدراسة
سعت الدراسة تعرف اثراستعمال الأنموذج المعملي في تصحيح المفاهيم الرياضية شائعة الخطأ لدى طلاب الصف الأول المتوسط بالإجابة عن السؤال "ما اثر استعمال الأنموذج المعملي في تصحيح المفاهيم الرياضية شائعة الخطأ لدى طلاب الصف الأول المتوسط" ولتحقيق هدف الدراسة وضعت الفرضية الصفرية "لايوجد فرق ذو دلالة إحصائية عند مستوى الدلالة (0.05) بين متوسطي درجات طلاب المجموعة التجريبية الذين يدرسون المادة المقرر
Background: Most primary Health Care Centers (PHCCs) in Iraq have a referral system records; however, this mechanism does not function well because of the lack of other requirements for an efficient referral system.
Objective: To assess the practice & opinion of doctors in PHCs toward the referral system, and to determine the doctors in PHC's commitment to referral system instructions and guidelines.
Subjects and methods: A cross-sectional study with analytic elements was conducted in nine health directorates in Iraq, from the 1st October 2018 – 30th June 2019.One PHC was selected randomly form each sector in every governorate, A questionnaire was used to collect the required information.
... Show MoreCoagulation is the most important process in drinking water treatment. Alum coagulant increases the aluminum residuals, which have been linked in many studies to Alzheimer's disease. Therefore, it is very important to use it with the very optimal dose. In this paper, four sets of experiments were done to determine the relationship between raw water characteristics: turbidity, pH, alkalinity, temperature, and optimum doses of alum [ .14 O] to form a mathematical equation that could replace the need for jar test experiments. The experiments were performed under different conditions and under different seasonal circumstances. The optimal dose in every set was determined, and used to build a gene expression model (GEP). The models were co
... Show MoreIn this paper thermo-hydrodynamic characteristics were investigated experimentally for a new type shell-helical coiled tube heat exchanger used as a storage tank of closed loop solar water heater system. Triple concentric helical coils were made of copper tubes of (12.5mm OD and 10mm ID) with coils diameter of (207, 152.2, 97mm) for outer, middle and inner coils respectively. The experiments were carried out during a clear sky days of (March and April 2012). The parameters studied in this work are: history of average temperature of shell side of the storage tank, collector heat gain, heat rejected from coils to shell side of the storage tank, collector efficiency, thermal effectiveness of the heat exchanger (storage tank), and pressure d
... Show MoreElectromyography (EMG) is being explored for evaluating muscle activity. For gait analysis, EMG needs to be small, lightweight, portable device, and with low power consumption. The proposed superficial EMG (sEMG) system is aimed to be used in rehabilitation centers and biomechanics laboratories for gait analysis in Iraq.
The system is built using MyoWare, which is controlled by using STM32F100 microcontroller. The sEMG signal is transferred via Bluetooth to the computer (about 30m range) for further processing. MATLAB is used for sEMG signal conditioning. The overall system cost (without computer) is about $80. The proposed system is validated using wired NORAXON EMG using the mean root mean squared metho
... Show MoreThe study aimed to identify the reality of the application of cost accounting system in the contracting institutions in Saudi Arabia, and the extent of the reflection of the application of this system on the effectiveness and efficiency of the general performance of these institutions. Where the research community consists of the contracting institutions operating in the Saudi Arabia, and then a suitable random sample was selected from seventy one institutions. The researchers used the historical method to track the previous studies as well as the descriptive approach to conducting the field study. The study data were analyzed by SPSS statistical program.
The results of this study conclude that there is a
... Show More