Preferred Language
Articles
/
alkej-148
Experimental Investigation of Using Evaporative Air Cooler for Winter Air-Conditioning in Baghdad
...Show More Authors

This paper presents an efficient methodology to design modified evaporative air-cooler for winter air-conditioning in Baghdad city as well as using it for summer air-conditioning by adding a heating process after the humidification process. laboratory tests were performed on a direct evaporative cooler (DEC) followed by passing the air on hot water through heat exchanger placed in the coolers air duct exit. The tests were conducted on the 2nd of December /2011 when the ambient temperature was 8.1°C and the relative humidity was  (68%). The air flow rate is assumed to vary between 0.069 to 0.209 kg/s with constant water flow rate of 0.03 kg/s in the heat exchanger. The performance is reported in terms of effectiveness of DEC, saturation efficiency of DEC, outlet temperature of air and cooling capacity. Heat transfer rate in heat exchanger mode is also estimated. The paper presents the mathematical development of the equations of thermal exchanges through DEC and HE. prediction of air condition that exits o this system show that the present system could bring the air stream to a comfortable winter zone .

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue May 23 2023
Journal Name
Journal Of Engineering
EXPERIMENTAL AND THEORETICAL STUDY OF TWO-PHASE HEAT PIPE
...Show More Authors

In this study, thermal characteristics of a two-phase closed heat pipe were investigated experimentally and theoretically. A two-phase closed heat pipe (copper container, Fluorocarbon FC-72 (C6F14) working fluid) was fabricated to examine its performance under the effect of input heat flux range of 250–1253 W/m2 , 70% fill charge ratio and various tilt angles. The temperature distribution along the heat pipe, input heat to evaporator section, and output heat from condenser were monitored. A comprehensive mathematical model was developed to investigate the steadystate heat transfer performance of a two-phase closed heat pipe. A steady state analytical model, is presented to determine important parameters on the design of two-phase close

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 14 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Effectiveness of Teaching Program on Nurses' Knowledge Concerning the Side Effects of Chemotherapy among Children with Leukemia at Oncology Wards in Baghdad City
...Show More Authors

Objective(s): to assess the effectiveness of educational program on nurses' knowledge concerning the side
effects of chemotherapy among children with leukemia.
Methodology: A descriptive analytic (quasi – experimental) design study was carried out at Baghdad City from
2
nd of October to 27th of June 2015. Non-probability sample of (35) male and female nurses was selected from
the Oncology Wards in Children Welfare, Child's Central and Baghdad Teaching Hospital. The study
instruments consisted of two major parts to meet the purposes of study. The first part is related to nurses'
demographic characteristics and the second part (four domains) is related to nurses' knowledge concerning the
side effects of chemothera

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 01 2021
Journal Name
Journal Of Physics: Conference Series
Detect Environment Pollution by GIS for Some Regions in Baghdad City
...Show More Authors
Abstract<p>The present study aims at assessing the status of heavy metals such as nickel, cadmium and lead to pollute some areas of Baghdad city. In this study the spectral absorption device and the program ArcGIS 10.2 will using. The soil samples were taken from five different locations in Baghdad, including Ameriya, Kadhimiya, Palestine Street, Jadiriyah and Taji for the 5cm depth layer on both sides of the road. This work on soil samples has been completed in two :phases 1 - Preparation of samples: For the purpose of converting solid material into a extract containing elements in the form of single ions can be estimated by the device 2-Determination of elements: Samples prepared to the device</p> ... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Mon Apr 01 2019
Journal Name
Journal Of Engineering
Investigation of Optimum Heat Flux Profile Based on the Boiling Safety Factor
...Show More Authors

An experimental study is conducted to investigate the effect of heat flux distribution on the boiling safety factor of its cooling channel. The water is allowed to flow in a horizontal circular pipe whose outlet surface is subjected to different heat flux profiles. Four types of heat flux distribution profiles are used during experiments: (constant distribution profile, type a, triangle distribution profile with its maximum in channel center, type b, triangle distribution profile with its maximum in the channel inlet, type c, and triangle distribution profile with its maximum in the channel outlet, type d). The study is conducted using heat sources of (1000 and 2665W), water flow rates of (5, 7 and 9 lit/min). The water

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jul 01 2013
Journal Name
2013 35th Annual International Conference Of The Ieee Engineering In Medicine And Biology Society (embc)
A preliminary investigation of the effect of force variation for myoelectric control of hand prosthesis
...Show More Authors

View Publication
Scopus (37)
Crossref (25)
Scopus Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
THEORETICAL AND EXPERIMENTAL STUDY ON THERMAL PERFORMANCE OF CLOSED WET COOLING TOWER
...Show More Authors

Thermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 09 2023
Journal Name
College Of Islamic Sciences
The door of speaking souls From the book explaining the features of the origins of religion For Sheikh Abdul Rahman bin Abdullah Al-Khonji study and investigation
...Show More Authors

Praise be to God who created the soul, perfected it, and inspired it with its immorality and piety. He says in His Noble Book: ﭤ Fajr: 27-30 Glory be to You, O God! O Lord, on whom I have chosen for You as a beloved from myself and the soul of the two worlds, may our master Muhammad be sacrificed for him, who enlightened the horizons with his introduction to enlightenment. It soon ends with the end of pleasure, which is the opposite of the pleasure of thought and meaning, as it is permanent and continuous, and from here we see that the Messenger of God, may God’s prayers and peace be upon him, urges us in various places to seek knowledge and fortify the soul and thought in a way that raises one’s status and protects him from the st

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 27 2021
Journal Name
Iraqi National Journal Of Nursing Specialties
Level of Depression and Anxiety among School Age Children with Acute Lymphoblastic Leukemia under Chemotherapy Treatment at Pediatric Teaching Hospitals in Baghdad City
...Show More Authors

Objective(s): To assess the level of depression and anxiety among school age children with acute lymphoblastic leukemia under chemotherapy treatment and to find out the relationship between the level of depression and anxiety among the affected children and their demographic characteristics.
Methodology: A cross-sectional study was conducted on school age children both gender having acute lymphoblastic leukemia under chemotherapy treated and their age between 6 years to 12 years. The study started from the period of September, 19th 2020 to March,1st 2021. Non-probability (Purposive) sample of (114) children with acute lymphoblastic leukemia under chemotherapy was selected in attending hospital wards, outpatient and counseling clinics

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 31 2015
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study of the Thermal Diffusivity and Heat Capacity Concerning Some Duplex Stainless Steel
...Show More Authors

Abstract

In the present work, thermal diffusivity and heat capacity measurements have been investigated in temperature range between RT and 1473 K for different duplex stainless steel supplied by Outokumpu Stainless AB, Sweden. The purpose of this study is to get a reliable thermophysical data of these alloys and to study the effect of microstructure on the thermal diffusivity and heat capacity value. Results show the ferrite content in the duplex stainless steel increased with temperature at equilibrium state. On the other hand, ferrite content increased with increasing Cr/Ni ratio and there is no significant effect of ferrite content on the thermal diffusivity value at room temperature. Furthermore, the heat capacity of all sam

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 31 2017
Journal Name
Al-khwarizmi Engineering Journal
Emergency Fuel Rationing system using RFID Smart Cards
...Show More Authors

Rationing is a commonly used solution for shortages of resources and goods that are vital for the citizens of a country. This paper identifies some common approaches and policies used in rationing as well asrisks that associated to suggesta system for rationing fuelwhichcan work efficiently. Subsequently, addressing all possible security risks and their solutions. The system should theoretically be applicable in emergency situations, requiring less than three months to implement at a low cost and minimal changes to infrastructure.

View Publication Preview PDF
Crossref