Background. The anterior communicating artery (ACoA) complex consists of the ACoA, the pre-and post-communicating segments of the anterior cerebral artery, and the recurrent artery of Heubner. It is the most common site for anatomical variations in the circle of Willis. Such variations can mimic intracranial aneurysms. Case description. A 30-year-old female presented with recurrent episodes of extreme headache and bilateral tinnitus. A brain computed tomography (CT) scan showed no significant lesions, while her CT-angiography (CTA) showed an enlarged vascular lesion at the ACoA, raising the suspicion for an ACoA aneurysm. A repeated CTA revealed a rare anatomical variation with a pattern of cross dominance in the ACoA complex; the left A1 and right A2 were dominant-enlarged, resulting in an enlargement of the ACoA. The presence of an ACoA aneurysm was hence excluded and the patient was managed conservatively. At 6-month follow-up, CTA showed no new findings. Conclusion. ACoA enlargement can result from unequal hemodynamics around the ACoA complex, which may be mistaken for an aneurysm. A thorough study of the imaging data is of pivotal importance and may change the management strategy.
Central and Eastern European Online Library - CEE journals, documents, articles, periodicals, books available online for download, Zeitschrfitendatenbank, Online Zeitschriften, Online Zeitschriftendatenbank
Systemic lupus erythematosus (SLE) is the prototypic multisystem autoimmune disorder with a broad spectrum of clinical presentations encompassing almost all organs and tissues. Aimes of study determination of integrin- linked kinase 1(ILK-1) and anti-smith antibody(ASAB) levels in serum of Iraqi patients with systemic lupus erythematosus, in addition, that ILK-1 may be as a diagnostic marker of SLE disease, and study the effect of systemic lupus erythematosus on renal function in these patients. This study included 100 females’ patients with systemic lupus erythematosus attending to the Rheumatology Unit in Baghdad Teaching Hospital, Medical City, (Baghdad), in addition to 30 healthy females as controller group were chosen without any chr
... Show MoreThe behavior investigation of castellated beams with fiber-reinforced lightweight concrete deck slab as a modified choice for composite steel-concrete beams affected by harmonic load is presented in this study. The experimental program involved six fixed-supported castellated beams of 2140mm size. Three types of concrete were included: Normal Weight Concrete (NWC), Lightweight Aggregate Concrete (LWAC), and Lightweight Fiber-Reinforced Aggregate Concrete (LWACF). The specimens were divided into two groups: the first comprised three specimens tested under harmonic load effect of 30Hz operation frequency for 3 days, then the residual strength was determined through static load application. The second group included three specimens ide
... Show MoreThis study aimed at identifying how children express the emerging coronavirus in general and according to their age groups (4-13 years) by analyzing 91 of their drawings published online, using the descriptive content analytical approach. The results showed that children's artistic expression of the virus came according to the concepts and ideas they carried about the virus for the age groups of (4-7 years) and (7-9 years), while it came according to visual perception for age groups (9-11 years), and from (11-13) years. Also, most children were aware about the presence of the virus and its widespread around the world, but (99%) of them do not realize the seriousness of the virus. It was confirmed that between (25-34%) of children were su
... Show MoreThe study of surface hardness, wear resistance, adhesion strength, electrochemical corrosion resistance and thermal conductivity of coatings composed from sodium silicate was prepared using graphite micro-size particles and carbon nano particles as fillers respectively of concentration of (1-5%), for the purpose of covering and protecting the oil distillation towers. The results showed that the sodium silicate coating reinforced with carbon nano-powder has higher resistance to stitches, mechanical wear, adhesive and thermal conductivity than graphite/sodium silicate composite especially when the ratio 5% and 1%, the electrochemical corrosion test confirmed that the coating process of stainless steel 304 lead to increasin
... Show MoreBackground: The aim of this in vitro study was to evaluate and compare the microleakage between Vertise Flow T M composite material and other conventional (Filtek Z250, riva light cure and SDR) composite materials when restoring CII mesial box only cavity at gingival margin through die penetration test Materials and methods: Forty maxillary first premolars were prepared with class II box design only cavities. Samples were divided into four groups of ten teeth according to material used: group I (FiltekZ250 only). Group II (SDR+FiltekZ250). Group III (Vertise Flow +FiltekZ250). Group IV (Riva light cure+ FiltekZ250). After 24 hrs. immersion in 2% in methylene blue, samples were sectioned and micro leakage was estimated. Results: None of the
... Show MoreThe experiment was conducted in two stages: first stage: determination of the most effective dose of Cyperus rotundus tubers aquatic extract in male rats for 5 days, which was concentrated as (200 mg/kg body weight). The second stage was designed to observe and test the protective effects of C. rotundus tubers aquatic extract in the liver and kidney functions of male rats exposed to cadmium chloride poisoning (5 mg/kg bw) for 30 days. The animals were divided into (4) groups within each group (5) animals weighted (200-220g). The results of oral dose of cadmium chloride showed a significant increase of (P˂0.05) in the activity of both enzymes Alanine aminotransferas
... Show More