Pesticides serve a crucial function in contemporary farming practices, safeguarding agricultural crops against pest infestations and boosting production outputs. However, indiscriminate use has caused environmental and human health damage. This study aimed to develop and validate a gas chromatography-flame ionization detection (GC-FID) methodology for the direct and routine analysis of spiromesifen residues in soil, leaves, and tomato fruits. The proposed method prioritizes simplicity by avoiding derivatization steps, offering advantages over existing approaches that utilize lengthy multi-step extraction or derivatization prior to GC analysis. A key novelty of this work is the development of a QuEChERS extraction coupled directly to GC-FID without further clean-up or chemical treatment steps, rendering the method more convenient and accessible for routine monitoring applications. Factors evaluated included: sample solvent; inlet and column temperature profiles; inlet type; sample volume; and injection technique. Recovery and matrix effect studies were conducted by fortifying tomato, leaf, and soil matrices at three different concentrations (0.5, 1, and 10 µg ml-1). Quadruplicate analyses (n = 4) yielded mean recoveries of 98.74% (fruits), 93.92% (leaves), and 94.18% (soil), confirming efficient extraction. Matrix effects were negligible at -7.9%, -7.8%, and -5.3%, respectively. The chromatographic linearity of the developed GC-FID method was excellent over the 0.002–20 µg ml-1 range with R2 > 0.9979. The method demonstrated good precision, with inter- and intra-day RSD% ranging from 0.06–1.8%, below the 3% limit. GC-MS analysis confirmed spiromesifen identification. Under greenhouse conditions, residual levels were 1.39 mg/kg in soil, 8.24 mg/kg in tomato, and 3.39 mg/kg in leaves. Dissipation followed first-order kinetics with a half-life of 1.6 days. The optimized GC-FID method is promising for monitoring spiromesifen usage and guiding agricultural practices. © (2024), (Iranian Chemical Society). All rights reserved.
A simple and novel method was developed by combination of dispersive liquid-liquid microextraction with UV spectrophotometry for the preconcentartion and determination of trace amount of malathion. The presented method is based on using a small volume of ethylenechloride as the extraction solvent was dissolved in ethanol as the dispersive solvent, then the binary solution was rapidly injected by a syringe into the water sample containing malathion. The important parameters, such the type and volume of extraction solvent and disperser solvent, the effect of extraction time and rate, the effect of salt addition and reaction conditions were studied. At the optimum conditions, the calibration graph was linear in the range of 2-100 ng mL-1 of ma
... Show MoreTwelve pends were selected and distributed on three verticals transects paths on the Tigers river in Al Rasheed county.Passing through land covers, that classified and covers the whole region. Based on the 8 Landsat of the year 2015. It was oriental classified by using Erdas 10.2 . The pedons were distributed on the area of each varicty of these classes. the series of soil according of the transect series (DW74,MMg,DMu6 , Df96) respectively were represented P1 , P2 , P3 , P4 .
The second transits series(DM97,MM5,DM96,DF115) respectively were represented P5 , P6 , P7 , P8 .The third transits series(DM46,MMg,MF12,MM11) re
... Show MoreMany objective optimizations (MaOO) algorithms that intends to solve problems with many objectives (MaOP) (i.e., the problem with more than three objectives) are widely used in various areas such as industrial manufacturing, transportation, sustainability, and even in the medical sector. Various approaches of MaOO algorithms are available and employed to handle different MaOP cases. In contrast, the performance of the MaOO algorithms assesses based on the balance between the convergence and diversity of the non-dominated solutions measured using different evaluation criteria of the quality performance indicators. Although many evaluation criteria are available, yet most of the evaluation and benchmarking of the MaOO with state-of-art a
... Show MoreA chemometric method, partial least squares regression (PLS) was applied for the simultaneous determination of piroxicam (PIR), naproxen (NAP), diclofenac sodium (DIC), and mefenamic acid (MEF) in synthetic mixtures and commercial formulations. The proposed method is based on the use of spectrophotometric data coupled with PLS multivariate calibration. The Spectra of drugs were recorded at concentrations in the linear range of 1.0 - 10 μg mL-1 for NAP and from 1.0 - 20 μg mL-1 for PIR, DIC, and MEF. 34 sets of mixtures were used for calibration and 10 sets of mixtures were used for validation in the wavelength range of 200 to 400 nm with the wavelength interval λ = 1 nm in methanol. This method has been used successfully to quant
... Show MoreThe experiment was conducted under shading (with the aid of Saran) condition on a nursery managed by the Baghdad Mayoralty during the season of 2014-2015 to study the effect of composed sheep manure extract on the growth and leaf nutrients content of tomato seedlings var. Wijdan. The experiment was composed of 6 treatments included the extract of sheep manure by hot (425C)and lmbient(205C) temperature water .The extract was diluted to the half by water and foliar applied to seedlings (multible application) or to the soil . Treatments also included the application of NPK chemical fertilizers as recommended and a control treatment through applying distilled water as foliar .The experiment was designed according to the randomized compl
... Show MoreThe existing study aimed to assess four soil moisture sensors’ capacitive (WH51 and SKU: S EN0193) and resistive (Yl69 and IC Station) abilities, which are affordable and medium-priced for their accuracy in six common soil types in the central region of Iraq. The readings’ calibration for the soil moisture sensor devices continued through two gravimetric methods. The first depended on the protocols’ database, while the second was the traditional calibration method. The second method recorded the lowest analysis error compared with the first. The moderate-cost sensor WH51 showed the lowest standard error (SE), MAD , and RMSE and the highest R² in both methods. The performance accuracy of WH51 was close to readings shown by the manufac
... Show MoreA study was carried out to determine the concentrations of trace metals in vegetables and fruits, which are locally available in the markets of Baghdad-samples of fourteen varieties of vegetables and fruits, belonging to Beta vulgaris, Brassica rapa, Daucus carota, Allium cepa, Eurica sativa, Malva silvestris, Coriandrum Sativum, Trigonella Foenum craecum, Anethum graveolens, Barassica oleracea, Phaseolus vulgaris, citrus reticulata, Pyrus malus, and Punica granatum. Analysis for Cd,Pb, Mn, Fe, Co, Ni, Cu and Zn were determined by flame atomic absorption spectrophotometry. The results indicated that the Malva silvestris recorded the highest concentrations of Cd and Mn while Allium cepa showed the highest concentrations of Pb and Cu. But
... Show MoreA study was carried out to determine the concentrations of trace metals in vegetables and fruits, which are locally available in the markets of Baghdad-samples of fourteen varieties of vegetables and fruits, belonging to Beta vulgaris, Brassica rapa, Daucus carota, Allium cepa, Eurica sativa, Malva silvestris, Coriandrum Sativum, Trigonella Foenum craecum, Anethum graveolens, Barassica oleracea, Phaseolus vulgaris, citrus reticulata, Py rus malus, and Punica granatum. Analysis for Cd,Pb, Mn, Fe, Co, Ni, Cu and Zn were determined by flame atomic absorption sp ectrophotometry. The results indicated that the Malva silvestris recorded the highest concentrations of Cd and Mn while Allium cepa showed the highest concentrations of Pb and Cu. But E
... Show More