Preferred Language
Articles
/
aBj_-pUBVTCNdQwC3oCP
Optimization and Validation of a GC-FID/QuEChERS Method for Quantitative Determination of Spiromesifen Residues in Tomato Fruits, Leaves and Soil Matrices
...Show More Authors

Pesticides serve a crucial function in contemporary farming practices, safeguarding agricultural crops against pest infestations and boosting production outputs. However, indiscriminate use has caused environmental and human health damage. This study aimed to develop and validate a gas chromatography-flame ionization detection (GC-FID) methodology for the direct and routine analysis of spiromesifen residues in soil, leaves, and tomato fruits. The proposed method prioritizes simplicity by avoiding derivatization steps, offering advantages over existing approaches that utilize lengthy multi-step extraction or derivatization prior to GC analysis. A key novelty of this work is the development of a QuEChERS extraction coupled directly to GC-FID without further clean-up or chemical treatment steps, rendering the method more convenient and accessible for routine monitoring applications. Factors evaluated included: sample solvent; inlet and column temperature profiles; inlet type; sample volume; and injection technique. Recovery and matrix effect studies were conducted by fortifying tomato, leaf, and soil matrices at three different concentrations (0.5, 1, and 10 µg ml-1). Quadruplicate analyses (n = 4) yielded mean recoveries of 98.74% (fruits), 93.92% (leaves), and 94.18% (soil), confirming efficient extraction. Matrix effects were negligible at -7.9%, -7.8%, and -5.3%, respectively. The chromatographic linearity of the developed GC-FID method was excellent over the 0.002–20 µg ml-1 range with R2 > 0.9979. The method demonstrated good precision, with inter- and intra-day RSD% ranging from 0.06–1.8%, below the 3% limit. GC-MS analysis confirmed spiromesifen identification. Under greenhouse conditions, residual levels were 1.39 mg/kg in soil, 8.24 mg/kg in tomato, and 3.39 mg/kg in leaves. Dissipation followed first-order kinetics with a half-life of 1.6 days. The optimized GC-FID method is promising for monitoring spiromesifen usage and guiding agricultural practices. © (2024), (Iranian Chemical Society). All rights reserved.

Scopus
Publication Date
Sun Jun 07 2009
Journal Name
Baghdad Science Journal
Compatibility between Pseudomonas fluorescens and Trichoderma harzianum in disease control of Fusarium tomato wilt under greenhouse condition .
...Show More Authors

This study was conducted to evaluate the efficacy of 6 isolates of Pseudomonas fluorescens and Trichoderma harzianum and there combination against Fusarium tomato wilt disease caused by Fusarium oxysporum F.sp. Lycopersisi under green house condition .The isolates of bacteria (B3) and Trichoderma (T1) were found to be highly effective in reducing the disease incidence to 13.3% , 21% respectively , compared to control treatment (40%).Furthermore, disease severity was reduced to 28 and 30% respectively in comparison to control (90%) .Colonization of the roots (cfu /g fresh root weight )by the two isolates whether alon or together was extremely high . The combination treatment had a high ability in reducing disease incidenece and sev

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jul 31 2022
Journal Name
Iraqi Geological Journal
A Review of Historical Studies for Water Saturation Determination Techniques
...Show More Authors

Water saturation is the most significant characteristic for reservoir characterization in order to assess oil reserves; this paper reviewed the concepts and applications of both classic and new approaches to determine water saturation. so, this work guides the reader to realize and distinguish between various strategies to obtain an appropriate water saturation value from electrical logging in both resistivity and dielectric has been studied, and the most well-known models in clean and shaly formation have been demonstrated. The Nuclear Magnetic Resonance in conventional and nonconventional reservoirs has been reviewed and understood as the major feature of this approach to estimate Water Saturation based on T2 distribution. Artific

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Crossref
Publication Date
Sun Dec 06 2009
Journal Name
Baghdad Science Journal
Decoding Reed- Muller Codes by Using Hadamard Matrices
...Show More Authors

This paper discusses the problem of decoding codeword in Reed- Muller Codes. We will use the Hadamard matrices as a method to decode codeword in Reed- Muller codes.In addition Reed- Muller Codes are defined and encoding matrices are discussed. Finally, a method of decoding is explained and an example is given to clarify this method, as well as, this method is compared with the classical method which is called Hamming distance.

View Publication Preview PDF
Crossref
Publication Date
Wed Dec 13 2017
Journal Name
Al-khwarizmi Engineering Journal
Optimization of Friction Stir Welding Process Parameters of Dissimilar AA2024-T3 and AA7075-T73 Aluminum Alloys by Using Taguchi Method
...Show More Authors

The aim of present study is to determine the optimum parameters of friction stir welding process and known the most important parameter along with percentage contribution of each parameter which effect on tensile strength and joint efficiency of FS welded joint of  dissimilar aluminum alloys AA2024-T3 and AA7075-T73 of 3 mm thick plates by applied specific number of experiments using Taguchi method .AA2024 was placed on the advancing side and AA7075 on the retreating side. FSW was achieved under three different rotation speeds (898, 1200 and 1710) rpm, three different welding speeds (20, 45 and 69) mm\min , three different pin profiles (cylindrical, threaded cylindrical and cone) and tool tilt angle 2. Taguchi method w

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 05 2052
Journal Name
Partial Differential Equations In Applied Mathematics
A hybrid analytical method for fractional order Klein–Gordon and Burgers equations
...Show More Authors

Scopus
Publication Date
Tue Apr 01 2014
Journal Name
International Communications In Heat And Mass Transfer
Determination of a time-dependent thermal diffusivity and free boundary in heat conduction
...Show More Authors

View Publication
Scopus (18)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
A sensitive spectrophotometric determination of tadalafil in pharmaceutical preparations and industrial wastewater samples
...Show More Authors

A simple, accurate, precise, rapid, economical and a high sensitive spectrophotometric method has been developed for the determination of tadalafil in pharmaceutical preparations and industrial wastewater samples, which shows a maximum absorbance at 204 nm in 1:1 ethanol-water. Beer's law was obeyed in the range of 1-7?g/ mL ,with molar absorptivity and Sandell ? s sensitivity of 0.783x105l/mol.cm and 4.97 ng/cm2respectively, relative standard deviation of the method was less than 1.7%, and accuracy (average recovery %) was 100 ± 0. 13. The limits of detection and quantitation are 0.18 and 0.54 µg .ml-1, respectively. The method was successfully applied to the determination of tadalafil in some pharmaceutical formulations

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Sep 20 2025
Journal Name
Euphrates Journal Of Agricultural Science
EFFECT OF NITROGEN , IRON AND THE METHODOF APPLICATIONON SOME NUTRIENTS ABSORPTION FOR APPLE LEAVES
...Show More Authors

View Publication
Publication Date
Wed Mar 01 2023
Journal Name
Egyptian Journal Of Chemistry
First- and Second-Derivative Spectrophotometry for Simultaneous Determination of lorazepam and clonazepam in pharmaceutical formulations
...Show More Authors

The present study describes employing zero-, 1st - and 2nd -order derivative spectrophotometric methods have been developed for determination of lorazepam (LORA) and clonazepam (CLON) in commercially available tablets. LORA was determined by means of 1st (D1), 2nd (D2) derivative spectrophotometric techniques using zero cross, peak height, and Peak area. D1 used for the determination of CLON by using zero cross and peak height while D2 (zero cross) was used for the determination of CLON. The method was established to be linear in concentration containing different ratios of LORA and CLON range of (20-200 mg/L) and (5-35 mg/L) at wavelength range (250 -370 nm), (210-370nm) respectively. The proposed techniques are highly sensitive, precise a

... Show More
Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Methods And Objects Of Chemical Analysis
Derivative Spectrophotometric Determination For Simultaneous Estimation Of Isoniazid And Ciprofloxacin In Mixture And Pharmaceutical Formulation
...Show More Authors

A simple analytical method was used in the present work for the simultaneous quantification of Ciprofloxacin and Isoniazid in pharmaceutical preparations. UV-Visible spectrophotometry has been applied to quantify these compounds in pure and mixture solutions using the first-order derivative method. The method depends on the first derivative spectrophotometry using zero-cross, peak to baseline, peak to peak and peak area measurements. Good linearity was shown in the concentration range of 2 to 24 μg∙mL-1 for Ciprofloxacin and 2 to 22 μg∙mL-1 for Isoniazid in the mixture, and the correlation coefficients were 0.9990 and 0.9989 respectively using peak area mode. The limits of detection (LOD) and limits of quantification (LOQ) wer

... Show More
View Publication Preview PDF
Scopus (16)
Crossref (8)
Scopus Clarivate Crossref