Biomarkers such as Interleukin-6 (IL-6), Procalcitonin (PCT), C-reactive protein (CRP) and Neutrophil-Lymphocyte Ratio (NLR) have a role in the pathogenesis of severe coronavirus disease 2019 (COVID-19). The aim of this study was to explore the differences between serum levels of such biomarkers in severe and non-severe COVID-19 cases and compare them with normal people and to evaluate the sociodemographic variables and chronic diseases effect on the severity of COVID-19. The study included 160 subjects, divided into two groups, a case group of 80 patients, and a control group of 80 normal persons. The case group was divided into two subgroups: 40 severe COVID-19 patients and 40 patients with non-severe disease. Blood IL-6 was assessed by an enzyme-linked immunosorbent assay (ELISA), PCT by an immunoassay, CRP by an immunoturbidimetric assay and NLR from CBC. The levels of IL-6, PCT, CRP, and NLR were significantly higher in the case group than in control group (p= 0.001, for all). However, there was no difference between these biomarkers level in the non-severe COVID-19 subgroup and the control group (p>0.05 for all). The proportion of severe COVID-19 was significantly higher in patients aged >50 years, and in patients with chronic diseases (p=0.046 and p=0.001, respectively). We also found a strong correlation between such biomarkers and old age, and chronic diseases with the disease severity. There was a significant difference in the level of the three biomarkers (IL-6, PCT, CRP, and NLR) between patients’ subgroups and the control group. In conclusion, since the levels of these biomarkers are correlated with the severity of the COVID-19 disease, and there was a difference in the levels between the groups with severe and non-severe symptoms, we suggest a role of these biomarkers in predicting the severity COVID-19 disease and its poor prognosis.
In this work, the effect of aluminum (Al) dust particles on the DC discharge plasma properties in argon was investigated. A magnetron is placed behind the cathode at different pressures and with varying amounts of Al. The plasma temperature (Te) and density (ne) were calculated using the Boltzmann equation and Stark broadening phenomena, which are considered the most important plasma variables through which the other plasma parameters were calculated. The measurements showed that the emission intensity decreases with increasing pressure from 0.06 to 0.4 Torr, and it slightly decreases with the addition of the NPs. The calculations showed that the ne increased and Te decreased with pressure. Both Te and ne were reduced by increasing
... Show MoreBackground: preparation of root canals is an important step in root canal treatment. Mechanical instrumentation of root canals cause an irregular layer of debris, known as the smear layer. As a result, several studies reported that preferring the removal of the smear layer. Objective: To study the influence of the energy (100 mJ) of Erbium, Chromium: Yttrium Scandium Gallium Garnet (Er,Cr:YSGG) laser at short pulse duration (60 μs) on smear layer removal of apical third after using Photon induced photoacoustic streaming technique. Materials and methods: Eighteen straight single-rooted mandibular premolars were used. The roots length were uniform to 14mm from the anatomic apex and
... Show MoreThis study was conducted to determine the effect of different concentrations of ethanol extract of propolis against two fungi Botrytis cinerea, Altrnaria sp. The most important chemical constituents of propolis diagnosed by the Infra Red Spectroscopy, were the Flavonoids specificaly. Results showed a high antifungal activity of ethanol extract of propolis, evidently with a high concentration of extract (5) mg\ml, which completely inhibited the radial growth on both solid and liquid media (PDA &PD Broth ) of both fungi . We observed that , ethanol extract p
... Show MoreThe adsorption study of thymol, was carried out at (25±0.1) °C, using granulated surfactant modified Iraqi Na – montmorillonite clay (initiated modified bentonite); in a down-flow packed column, the modified mineral was characterized by FT-IR spectroscopy. A linear calibration graph for thymol was obtained, which obey Beer's law in the concentration range of 5-50 mg/L at 274 nm against reagent blank. Single-factor-at-a-time approach; showed that the equilibrium time required for complete adsorption was 45 minute with flow rate (4.0drop/ mint). The adsorption of thymol increased with rising pH of the adsorbate solution, increase of solute uptake when the initial adsor
... Show MoreCoagulation - flocculation are basic chemical engineering method in the treatment of metal-bearing industrial wastewater because it removes colloidal particles, some soluble compounds and very fine solid suspensions initially present in the wastewater by destabilization and formation of flocs. This research was conducted to study the feasibility of using natural coagulant such as okra and mallow and chemical coagulant such as alum for removing Cu and increase the removal efficiency and reduce the turbidity of treated water. Fourier transform Infrared (FTIR) was carried out for okra and mallow before and after coagulant to determine their type of functional groups. Carbonyl and hydroxyl functional groups on the surface of
... Show MoreThe corrosion of carbon steel in single phase (water with 0.1N NaCl ) and two immiscible phases (kerosene-water) using turbulently agitated system is investigated. The experiments are carried out for Reynolds number (Re) range of 38000 to 95000 corresponding to rotational velocities from 600 to 1400 rpm using circular disk turbine agitator at 40 0C. In two-phase system test runs are carried out in aqueous phase (water) concentrations of 1 % vol., 5 % vol., 8% vol., and 16% vol. mixed with kerosene at various Re. The effect of Reynolds number (Re), percent of dispersed phase, dispersed drops diameter, and number of drops per unit volume on the corrosion rate is investigated and discussed. Test runs are carried out using two types of
... Show MoreHeuristic approaches are traditionally applied to find the optimal size and optimal location of Flexible AC Transmission Systems (FACTS) devices in power systems. Genetic Algorithm (GA) technique has been applied to solve power engineering optimization problems giving better results than classical methods. This paper shows the application of GA for optimal sizing and allocation of a Static Compensator (STATCOM) in a power system. STATCOM devices used to increase transmission systems capacity and enhance voltage stability by regulate the voltages at its terminal by controlling the amount of reactive power injected into or absorbed from the power system. IEEE 5-bus standard system is used as an example to illustrate the te
... Show MoreThe objective of the current research is to find an optimum design of hybrid laminated moderate thick composite plates with static constraint. The stacking sequence and ply angle is required for optimization to achieve minimum deflection for hybrid laminated composite plates consist of glass and carbon long fibers reinforcements that impeded in epoxy matrix with known plates dimension and loading. The analysis of plate is by adopting the first-order shear deformation theory and using Navier's solution with Genetic Algorithm to approach the current objective. A program written with MATLAB to find best stacking sequence and ply angles that give minimum deflection, and the results comparing with ANSYS.
The present research was conducted to reduce the sulfur content of Iraqi heavy naphtha by adsorption using different metals oxides over Y-Zeolite. The Y-Zeolite was synthesized by a sol-gel technique. The average size of zeolite was 92.39 nm, surface area 558 m2/g, and pore volume 0.231 cm3/g. The metals of nickel, zinc, and copper were dispersed by an impregnation method to prepare Ni/HY, Zn/HY, Cu/HY, and Ni + Zn /HY catalysts for desulfurization. The adsorptive desulfurization was carried out in a batch mode at different operating conditions such as mixing time (10,15,30,60, and 600 min) and catalyst dosage (0.2,0.4,0.6,0.8,1, and 1.2 g). The most of the sulfur compounds were removed at 10 min for all catalyst ty
... Show More