Preferred Language
Articles
/
aBd7t44BVTCNdQwChVcy
Phylogenetic Relationship of Iraqi Vespa orientalis Linnaeus 1771 Wasps Using Mitochondrial CO1
...Show More Authors
Abstract<p>Oriental wasps are scavengers, and they have also represented an enormous issue for beekeepers, they destroy beehives and reduce the flight of bees. In addition, the sting of hornets may cause medical problems, which differ according to the response of the individuals, including severe sensitivity, swelling, and slight pain. This study provides the first molecular phylogeny of the oriental wasp <italic>Vespa orientalis</italic> L. in Iraq. Mitochondrial DNAs of the 547bp fragment cytochrome oxidase subunit 1 (CO1) area were sequenced and analyzed from 10 wasp specimens collected in the north, middle, and south of Iraq. The CO1 gene found in the Iraqi isolates was used to create a Bayesian interference. Maximum likelihood (ML) was used to create the phylogenetic tree. Results, according to the results of the phylogenetic analysis, the CO1 gene may be used to positively identify every sample, and there is a close connection between the sequences of samples from various regions of Iraq, with 100% of the samples clustering together. PCR successfully amplified 547bp products for all examined oriental wasp samples. Considering the similarity in the sequences, the Iraqi local species are classified as <italic>V. orientalis</italic>. Conclusion, in this study, <italic>V. orientalis</italic> isolates which were collected from different geographical regions in Iraq were closed and there was low variation. The DNA barcode component of CO1 was found to be an effective method for the quick and precise identification of Iraqi oriental wasps.</p>
Scopus Crossref
View Publication
Publication Date
Fri Dec 23 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Sensitive Cloud Point Extraction Method for the Determination of Isoxsuprine Hydrochloride in Pharmaceutical forms using Spectrophotometry
...Show More Authors

      A simple and highly sensitive cloud point extraction process was suggested for preconcentration of micrograms amount of isoxsuprine hydrochloride (ISX) in pure and pharmaceutical samples. After diazotization coupling of ISX with diazotized sulfadimidine in alkaline medium, the azo-dye product quantitatively extracted into the Triton X-114 rich phase, dissolved in ethanol and determined spectrophotometrically at 490 nm. The suggested reaction was studied with and without extraction and simple comparison between the batch and CPE methods was achieved. Analytical variables including concentrations of reagent, Triton X-114 and base, incubated temperature, and time were carefully studied. Under the selected optimum conditions,

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sat Aug 01 2015
Journal Name
Journal Of Bridge Engineering
Torsional Analysis of Multicell Concrete Box Girders Strengthened with CFRP Using a Modified Softened Truss Model
...Show More Authors

Scopus (35)
Crossref (28)
Scopus Clarivate Crossref
Publication Date
Mon Mar 23 2020
Journal Name
Baghdad Science Journal
Surfactant Cloud Point Extraction as a Procedure of Preconcentrating for Metoclopramide Determination Using Spectro Analytical Technique
...Show More Authors

In current article an easy and selective method is proposed for spectrophotometric estimation of metoclopramide (MCP) in pharmaceutical preparations using cloud point extraction (CPE) procedure. The method involved reaction between MCP with 1-Naphthol in alkali conditions using Triton X-114 to form a stable dark purple dye. The Beer’s law limit in the range 0.34-9 μg mL-1 of MCP with r =0.9959 (n=3) after optimization. The relative standard deviation (RSD) and percentage recoveries were 0.89 %, and (96.99–104.11%) respectively. As well, using surfactant cloud point extraction as a method to extract MCP was reinforced the extinction coefficient(ε) to 1.7333×105L/mol.cm in surfactant-rich phase. The small volume of organi

... Show More
View Publication Preview PDF
Scopus (14)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri Jun 01 2018
Journal Name
Journal Of Engineering
Experimental Study of Optimum Chilled Water Distribution Configuration in Air Conditioning Terminal Unit Using RSM Technique
...Show More Authors

The distribution of chilled water flow rate in terminal unit is an important factor used to evaluate the performance of central air conditioning unit. A prototype of A/C unit has been made, which contains three terminal units with a complete set of accessories (3-way valve, 2-way valve, and sensors) to study the effect of the main parameters, such as total water flow rate and chilled water supply temperature with variable valve opening. In this work, 40 tests were carried out. These tests were in two groups, 20 test for 3-way valve case and 20 test for 2-way valve case. These tests were performed at three levels of valve opening, total water flow rate and water supply temperature according to the design matrices establis

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Aip Conference Proceedings
Analysis of performance measures with single channel fuzzy queues under two class by using ranking method
...Show More Authors

View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Thu Jan 31 2019
Journal Name
Journal Of Engineering
Enhancement in Lubricating, Rheological, and Filtration Properties of Unweighted Water-Based Mud Using XC Polymer NPs
...Show More Authors

In this research, an enhancement in lubricating, rheological, and filtration properties of unweighted water-based mud is fundamentally investigated using XC polymer NPs with 0.2gm, 0.5gm, 1gm, 2gm, and 4gm concentrations. Bentonite, that had been used in the preparation of unweighted water-based mud, was characterized using XRF-1800 Sequential X-ray Fluorescence Spectrometer, XRD-6100/7000 X-ray Diffractometer, and Malvern Mastersizer 2000 particle size analyzer, respectively. Lubricating, rheology and filtration properties of unweighted water-based mud were measured at room temperature (35°C) using OFITE EP and Lubricity Tester, OFITE Model 900 Viscometer, and OFITE Low-Pressure Filter Press, respectively. XC Polymer N

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Tue Mar 30 2021
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Treating Wet Oil in Amara Oil Field Using Nanomaterial (SiO2) With Different Types of De emulsifiers
...Show More Authors

One of the most important problems in the oil production process and when its continuous flow, is emulsified oil (w/o emulsion), which in turn causes many problems, from the production line to the extended pipelines that are then transported to the oil refining process. It was observed that the nanomaterial (SiO2) supported the separation process by adding it to the emulsion sample and showed a high separation rate with the demulsifiers (RB6000) and (sebamax) where the percentage of separation was greater than (90 and 80 )%  respectively, and less than that when dealing with (Sodium dodecyl sulfate and Diethylene glycol), the percentage of separation was (60% and 50%) respectively.

   The high proportion

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Oct 29 2020
Journal Name
The 11th International Renewable Energy Congress (irec 2020)
Thermal efficiency Optimization of the evacuated tube solar water heater system by using mirror flat reflector
...Show More Authors

In this paper a comparison of the experimental of evacuated tube solar water heater systems with and without mirror flat reflector. The aim of using the reflector to improve thermal efficiency, and the data gathered which are (temperature, solar irradiation and time) for three days were compared. the results from compared data the temperature lower increase in evacuated tube solar water heater system without reflector than the temperature increase in evacuated tube solar water heater system with reflector .The results show (53, 39, 35) % for three days respectively that the evacuated tube solar water heater system with reflector has higher thermal efficiencies than the results (47, 28, 30) % for three days respectively thermal efficiencies

... Show More
View Publication
Crossref (4)
Crossref
Publication Date
Fri Dec 23 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Sensitive Cloud Point Extraction Method for the Determination of Isoxsuprine Hydrochloride in Pharmaceutical forms using Spectrophotometry
...Show More Authors

      A simple and highly sensitive cloud point extraction process was suggested for preconcentration of micrograms amount of isoxsuprine hydrochloride (ISX) in pure and pharmaceutical samples. After diazotization coupling of ISX with diazotized sulfadimidine in alkaline medium, the azo-dye product quantitatively extracted into the Triton X-114 rich phase, dissolved in ethanol and determined spectrophotometrically at 490 nm. The suggested reaction was studied with and without extraction and simple comparison between the batch and CPE methods was achieved. Analytical variables including concentrations of reagent, Triton X-114 and base, incubated temperature, and time were carefully studied. Under the selected opti

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Baghdad Science Journal
Determination of Sulfacetamide Sodium in Pure and Their Pharmaceutical Formulations by Using Cloud Point Extraction Method
...Show More Authors

      In this study, simple, low cost, precise and speed spectrophotometric methods development for evaluation of sulfacetamide sodium are described. The primary approach contains conversion of sulfacetamide sodium to diazonium salt followed by a reaction with p-cresol as a reagent in the alkaline media.  The colored product has an orange colour with absorbance at λmax 450 nm. At the concentration range of (5.0-100 µg.mL-1), the Beer̆ s Low is obeyed with correlation coefficient (R2= 0.9996), limit of detection as 0.2142 µg.mL-1, limit of quantification as 0.707 µg.mL-1 and molar absorptivity as 1488.249 L.mol-1.cm-1. The other approach, cloud point extraction w

... Show More
View Publication Preview PDF
Scopus (8)
Scopus Clarivate Crossref