The field experiment was conducted with the aim of developing and testing an automatic sprayer for agricultural spray experiments and studying the effect of spray pressure, spray speed and spray height on the spraying process. The effects of the major spraying factors (pressure, speed, and height) on the spraying performance of the automatic sprayer were studied. This study included several traits: First - the drop sizes - Second - the penetration of the spray into the vegetation cover - Third, the spray wasted. The results showed: - First: - Increase in coverage percentage when using the first speed, 2 km / h, which amounted to 26.85%. An increment in the spraying penetration of the vegetation cover was observed at the second speed, 4 km/h, reaching 70%. Second - Pressure: The increment in pressure was accompanied by an increment in the coverage trait at the third pressure 3 bar, which amounted to 24.37%. The penetration trait was 81% at pressure of two bar, and wastage increased at the second pressure of two bar, which amounted to 25%. Spraying height: - Height) 40 & 50 cm (have no significant effect on the trait of coverage. However, it was significant in the trait of spraying penetration of the vegetation cover, as it reached at the first height (40 cm) 53% and at the second height (50 cm) 74%, and the trait of the lost at the first height, 40 cm was 13%, and at the second height, 50 cm, it reached 23%. It is concluded from the data, the extent of the effect that the spraying factors show on the studied trait, as The factors value increased is accompanied by an increment in some trait, in contrast to others. So, it becomes clear the necessity of coordinating the values of the factors with each other to obtain an equal spray.
The ï¤- Multiple mixing ratios of ï§-transitions from levels of 56Fe populated in 56 56 ( , ) Fe n n Fe ï§ ï‚¢ reactions are calculated by using const. S.T.M. This method has been used in other works [3,7] but with pure transition or with transitions that can be considered as pure transitionsØŒ in our work we used This method for mixed ï§ - transitions in addition to pure ï§ - transitions. The experimental angular distribution coefficients a2 was used from previous works [1] in order to calculet ï¤- values. It is clear from the results that the ï¤- values are in good agreement or consistent, within associated errors, with those reported previously [1]. The discrepancies that occur
... Show MoreIn dieser Kurzgeschichte werden die Züge der Trümmerliteratur präzis dargestellt. Die wurde von Heinrich Böll im Jahr 1958 geschrieben. In der vorliegenden Arbeit konzentriere ich mich auf vielfältige Stoffe in Bezug auf die Lage nach dem Zweiten Weltkrieg. So gab ich dieser Arbeit einen besonderen Titel, der die Dimensionen dieser Kurzgeschichte heißt. Ich meine hier, die profunde Interpretation dieses Werkes, denn ich fand zwar hinter einigen Wörtern eine ganze Geschichte, die uns der Erzähler dadurch zeigen wollte.
So teilte ich diese Wörter (Grab, Schatten, Last, Schrei) als Dimensionen, von denen diese Arbeit umgekreist wird.
Diese Arbeit besteht aus vier Kapiteln, die aufeinander aufgebaut sind. Im ersten K
... Show MoreAbstract: In the present work, the heat transfer of Nano Aluminum Oxide -NAO- has been studied practically to define the appropriate insulation conditions. This study focuses on finding of the amount of heat transfer through a glass substrate that is coated with nanoalumina doped on PMMA matrix. The optical and thermal properties were systematically investigated. The density of heat flow rate, was calculated in the range values (240-260) W/m2 while the optimum values confine between (250-260) W/m2 at temp. (25-35)Co. The results showed that the thermal insulation of the sample was significantly enhanced at temp. (30-50)Co. The simulated net heat transfer through window decreased linearly with incr
... Show MoreA free convective heat transfer from the inside surface of a uniformly heated vertical circular tube has been experimentally investigated under a constant wall heat flux boundary condition for laminar air flow in the ranges of RaL from 6.9108 to 5109. The effect of the different sections (restrictions) lengths placed at the exit of the heated tube on the surface temperature distribution, the local and average heat transfer coefficients were examined. The experimental apparatus consists of aluminum circular tube with 900 mm length and 30 mm inside diameter (L/D=30). The exit sections (restrictions) were included circular tubes having the same inside diameter as the heated tube but with different lengths of
... Show More<p><span>A Botnet is one of many attacks that can execute malicious tasks and develop continuously. Therefore, current research introduces a comparison framework, called BotDetectorFW, with classification and complexity improvements for the detection of Botnet attack using CICIDS2017 dataset. It is a free online dataset consist of several attacks with high-dimensions features. The process of feature selection is a significant step to obtain the least features by eliminating irrelated features and consequently reduces the detection time. This process implemented inside BotDetectorFW using two steps; data clustering and five distance measure formulas (cosine, dice, driver & kroeber, overlap, and pearson correlation
... Show MoreAbstract: The increased interest in developing new photonic devices that can support high data rates, high sensitivity and fast processing capabilities for all optical communications, motivates a pre stage pulse compressor research. The pre-stage research was based on cascading single mode fiber and polarization maintaining fiber to get pulse compression with compression factor of 1.105. The demand for obtaining more précised photonic devices; this work experimentally studied the behavior of Polarization maintaining fiber PMF that is sandwiched between two cascaded singe mode fiber SMF and fiber Bragg gratings FBG. Therefore; the introduced interferometer performed hybrid interference of both Mach-Zehnder
... Show MoreThis paper presents a computer simulation model of a thermally activated roof (TAR) to cool a room using cool water from a wet cooling tower. Modeling was achieved using a simplified 1-D resistance-capacitance thermal network (RC model) for an infinite slab. Heat transfer from the cooling pipe network was treated as 2-D heat flow. Only a limited number of nodes were required to obtain reliable results. The use of 6th order RC-thermal model produced a set of ordinary differential equations that were solved using MATLAB - R2012a. The computer program was written to cover all possible initial conditions, material properties, TAR system geometry and hourly solar radiation. The cool water supply was considered time
... Show MoreThis study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis
... Show MoreThis study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis of variance (ANO
... Show More