The study focused on examining the behavior of six concrete beams that were reinforced with glass fiber-reinforced polymer (GFRP) bars to evaluate their performance in terms of their load-carrying capacity, deflection, and other mechanical properties. The experimental investigation would provide insights into the feasibility and effectiveness of GFRP bars as an alternative to traditional reinforcement materials like steel bars in concrete structures. The GFRP bars were used in both the longitudinal and transverse directions. Each beam in the study shared the following specifications: an overall length of 2,400 mm, a clear span of 2,100 mm, and a rectangular cross-section measuring 300 mm in width and 250 mm in depth. To apply loads for testing, two-point static loads were placed at the middle third of the beam’s span, creating a shear span of 700 mm in length. The beams were categorized into three groups depending on the GFRP longitudinal reinforcement ratio in the tension and compression zones of the section. GFRP bars with a diameter of 15 mm were employed as longitudinal reinforcement, while closed GFRP stirrups with a diameter of 8 mm at 100 mm were utilized as transverse reinforcement throughout the structural element. Test results have indicated that the ultimate load capacity of doubly GFRP-reinforced concrete beams varies compared to singly GFRP-reinforced beams. The range of variation observed is between an increase of 8% and a decrease of 4%. Accordingly, the contribution of the GFRP bars in the compression zone is insignificant and could be ignored in design calculations. It was observed that the loading level at which crack spacing stabilized ranged between 31.3 and 87% of the experimental failure load. It seems that the crack spacing decreased with the increase in the reinforcement ratio.
The Evaluation of the immune response in Golden Hamsters experimentally infected with Leishmania donovani was determined in this study, particularly, the cellular immune response. Follow up has maintained to determine the Delayed Type of Hypersensitivity using skin test both in infected and control lab animals. Chicken red blood cells were used as a parameter to evaluate the immune system; they are dull and have the ability of immunization. Two concentrations of chicken R.B.C were examined to determine which gives the higher titration in Hamsters and those were 1.5 X 109 cell/ml and 3 X 109 cell/ml , the second concentration gave the maximum titration where then used in this work. After sensitization with Chicken R.B.C for both infected a
... Show MoreChitinase-3-like 1 protein (YKL-40) is a glycoprotein primarily produced in the arthritic joint and plays a crucial role in inflammatory processes. The aim of the study is to establish the role of YKL-40 as a biomarker for rheumatoid arthritis (RA) compared to proinflammatory biomarkers and disease activity. The study included 58 patients and 18 control. Diseases activity score (DAS-28) and clinical disease activity index (CDAI) were measured. Serum level of YKL-40, tumor necrosis factor-α (TNF-α), interleukin-1B (IL-1β), erythrocyte sedimentation (ESR), rheumatoid factor (RF), C-reactive protein (CRP), and anti-citrullinated protein antibody (ACPA) were assessed. The results showed that the median serum YKL-40 level which was 5.42
... Show MoreThis research Sought to identify the correlation relationships and the impact of each of the job description and perceived organizational support, Excellent Job performance of the heads of academic departments in the faculties of the University of Sulaymaniyah Iraqi Kurdistan Region, totaling (89) as President, and to achieve this was Default plan includes research variables as well as the formulation of a number of preparation fundamental assumptions, and researchers used a questionnaire for this purpose as a tool head of the collection of data and information, as it was distributed (80) copies, and the number of retrieved them (76) a copy of a valid statistical analysis, as well as conducting personal i
... Show MoreThe spray quality of two spraying agents with different physical properties was investigated under laboratory conditions to find whether the measurement of deposited drops could be affected by spraying those agents. The first spraying agent Moddus, which is a plant growth regulator, has a surface tension of 28 mN m-1 with almost half the value of the second spraying agent Kelpak (58 mN m-1). A mini boom sprayer containing three flat fan nozzles (XR 11003) was used in the test with three traveling speeds (4.74, 5.42 and 8.13 km. h-1). The test was performed to evaluate the quality of spray drops (spray coverage, spray density and stains diameter) after they were deposited on water sensitive papers (WSP). The results showed a higher ability o
... Show More