Preferred Language
Articles
/
_hcRn40BVTCNdQwCaBZx
Validity and reliability of three-dimensional modeling of orthodontic dental casts using smartphone-based photogrammetric technology
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Mon Apr 01 2019
Journal Name
The Saudi Dental Journal
Implementation and characterization of coating pure titanium dental implant with sintered β-TCP by using Nd:YAG laser
...Show More Authors

Objectives This work presents laser coating of grade 1 pure titanium (Ti) dental implant surface with sintered biological apatite beta-tricalcium phosphate (β-TCP), which has a chemical composition close to bone. Materials and methods Pulsed Nd:YAG laser of single pulse capability up to 70 J/10 ms and pulse peak power of 8 kW was used to implement the task. Laser pulse peak power, pulse duration, repetition rate and scanning speed were modulated to achieve the most homogenous, cohesive and highly adherent coat layer. Scanning electron microscopy (SEM), energy dispersive X-ray microscopy (EDX), optical microscopy and nanoindentation analyses were conducted to characterise and evaluate the microstructure, phases, modulus of elasticity

... Show More
View Publication
Scopus (26)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Sun Apr 01 2018
Journal Name
Journal Of Educational And Psychological Researches
Patient Satisfaction and its Relationship to Dental anxiety among patients of Dental Clinics in Baghdad city
...Show More Authors

Patient satisfaction and dental anxiety considered as an important factors in dental health care and treatment because they greatly affect the patient's cooperation with the dentist and the extent to which follows the guidelines, treatment and preventive instruction. The present study investigates the relationship between patient satisfaction and dental anxiety, as well as their relation to demographic variables such as gender, age, number of visits, and cultural level. The study was applied on a random sample of dental clinics in Baghdad city with total of (200) patient (108 male and 92 female). Two scales were used in this study, patient satisfaction scale PSS (included 9 aspects, constructed by authors) and Iraqi dental anxiety scale

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 04 2012
Journal Name
Baghdad Science Journal
Effect of Temperature on Reliability and Degradation of 0.63?m Laser Diode
...Show More Authors

The reliability of optical sources is strongly dependent on the degradation and device characteristics are critically dependent on temperature. The degradation behaviours and reliability test results for the laser diode device (Sony-DL3148-025) will be presented .These devices are usually highly reliable. The degradation behaviour was exhibited in several aging tests, and device lifetimes were then estimated. The temperature dependence of 0.63?m lasers was studied. An aging test with constant light power operation of 5mW was carried out at 10, 25, 50 and 70°C for 100hours. Lifetimes of the optical sources have greatly improved, and these optical sources can be applied to various types of transmission systems. Within this degradation range,

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Baghdad Science Journal
The Numerical Technique Based on Shifted Jacobi-Gauss-Lobatto Polynomials for Solving Two Dimensional Multi-Space Fractional Bioheat Equations
...Show More Authors

This article deals with the approximate algorithm for two dimensional multi-space fractional bioheat equations (M-SFBHE). The application of the collection method will be expanding for presenting a numerical technique for solving M-SFBHE based on “shifted Jacobi-Gauss-Labatto polynomials” (SJ-GL-Ps) in the matrix form. The Caputo formula has been utilized to approximate the fractional derivative and to demonstrate its usefulness and accuracy, the proposed methodology was applied in two examples. The numerical results revealed that the used approach is very effective and gives high accuracy and good convergence.

View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Dec 05 2023
Journal Name
Baghdad Science Journal
A Novel System for Confidential Medical Data Storage Using Chaskey Encryption and Blockchain Technology
...Show More Authors

Secure storage of confidential medical information is critical to healthcare organizations seeking to protect patient's privacy and comply with regulatory requirements. This paper presents a new scheme for secure storage of medical data using Chaskey cryptography and blockchain technology. The system uses Chaskey encryption to ensure integrity and confidentiality of medical data, blockchain technology to provide a scalable and decentralized storage solution. The system also uses Bflow segmentation and vertical segmentation technologies to enhance scalability and manage the stored data. In addition, the system uses smart contracts to enforce access control policies and other security measures. The description of the system detailing and p

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Crossref
Publication Date
Thu Jun 01 2017
Journal Name
American Journal Of Pharmaceutical Education
Exploring Electronic Communication Modes Between Iraqi Faculty and Students of Pharmacy Schools Using the Technology Acceptance Model
...Show More Authors

View Publication
Scopus (9)
Crossref (6)
Scopus Crossref
Publication Date
Fri Dec 19 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Load-deflection characteristics and force levels of coated nickel titanium orthodontic archwires
...Show More Authors

Background: Coated archwires have been introduced to improve esthetics during orthodontic treatment. Theaim of the present study was to evaluate and compare the load–deflection characteristics and force levels of six brands of coated nickel titanium orthodontic archwires using palatal and gingival deflection. Materials and methods: Ten round wires (0.016 inch) and ten rectangular wires (0.019x0.025 inch) were obtained from each of six brands (G&H, Opal, Ortho Technology, Dany, Hubit and Astar Companies). The load-deflection properties of these archwires were evaluated by the modified bending test usinga readymade dental arch model in both palatal and gingival directions at 37°C temperature using a universal material testing machi

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 19 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of bone density after six months from dental implants placement using Computed Tomography
...Show More Authors

Background: Determination of local bone mineral density (BMD) immediately after implant insertion play an important role in implant success rate, may offer comprehensive description of the bone, and give enough information to the surgeon prior to implant insertion and at follow up status. The aim of the present study is to evaluate the changes of local bone density in the dental implant recipient sites by using computerized tomography. Material and method: The sample consisted of (20) dental implants recipient sites, bone density assessment was done twice, immediately after implants insertion and after six months. Results: The mean HU of the bone around the implant insertion site, immediately after implant placement was 552.28 HU, and inc

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 01 2017
Journal Name
Journal Of Craniofacial Surgery
Lateral Ridge Splitting (Expansion) With Immediate Placement of Endosseous Dental Implant Using Piezoelectric Device
...Show More Authors

View Publication
Crossref (15)
Crossref
Publication Date
Mon Feb 13 2023
Journal Name
Bmc Oral Health
The reliability of using light therapy compared with LASER in pain reduction of temporomandibular disorders: a randomized controlled trial
...Show More Authors
Abstract<sec> <title>Background

Temporomandibular Disorders (TMD) refer to a group of symptoms where pain is the most leading cause to demand a treatment by the patient. Light therapies are of great importance at current times due to its biosafety and non-invasive quality when used for the management of TMD symptoms. This study aimed to evaluate the efficacy of red LED light with low-level LASER in treating TMD patients.

Materials and methods

A double-blind randomized clinical study was conducted and included 60 patients along 3 groups (20 for e

... Show More
View Publication
Crossref (14)
Crossref