Dynamic Thermal Management (DTM) emerged as a solution to address the reliability challenges with thermal hotspots and unbalanced temperatures. DTM efficiency is highly affected by the accuracy of the temperature information presented to the DTM manager. This work aims to investigate the effect of inaccuracy caused by the deep sub-micron (DSM) noise during the transmission of temperature information to the manager on DTM efficiency. A simulation framework has been developed and results show up to 38% DTM performance degradation and 18% unattended cycles in emergency temperature under DSM noise. The finding highlights the importance of further research in providing reliable on-chip data transmission in DTM application.
The impact of management control systems (MCS) on organizations performance empirical research has been the subject of numerous studies during the past decade in developed and emerging economies. In the contemporary competitive, complex and changing global business environment, firms are being challenged to adopt business models that enable them to address the strategic uncertainties and risks they face in their business environments. The main issue of this study is that management accounting researchers argue that one of the ways firms can continually rejuvenate themselves to survive and succeed in these complex and uncertain environments is to understand the role of management control systems in Formulating a b
... Show MoreObjective(s): To determine the impact of Chemotherapy upon the quality of life for patients with chronic myeloid
leukemia in Baghdad city.
Methodology: A descriptive study design was carried out The study was initiated from 30 January 2011 to October
2011.A purposive (non–probability) sample consisted of (130) patients with a chronic myeloid leukemia ,Who
attended to Baghdad Teaching Hospital and National Center for Research and Treatment of Hematology. The
sample criteria was the patients who were 18 years old and above, excluding the patients who suffered from
psychological problems and other chronic illnesses .A questionnaire was adopted and developed from European
Organization Research and treatment of Can
The research aims to find out the impact of wages and benefits systems on the performance of employees, which included the research community on a sample of employees in the company, and the sample consisted of (50) employees and an employee, A questionnaire composed as prepared (23) paragraph, use the promised statistically methods in data collected by the questionnaire analysis. The research reached a number of results, the most prominent of which were: There is a correlation between wage systems, benefits and performance of employees, and the presence of the impact of the systems of wages and benefits to the performance of employees. The research was presented a set of recommendations including: increasing the effectiveness of
... Show MoreClopidogrel is a prodrug that must be transformed into an active metabolite by hepatic cytochrome P450 (CYP) isoenzymes to prevent platelet clotting. Polymorphisms of the CYP2C19 gene can cause a reduction or complete loss of CYP2C19 enzyme activity resulting in inhibiting clopidogrel metabolism, effectiveness and increase stroke recurrence risk in ischemic stroke patients. This study aims to investigate the correlation between genetic polymorphisms in CYP2C19*2 and*3 and recurrent risk in patients with ischemic stroke taking clopidogrel 75mg in Kurdistan region –Iraq. This retrospective case-control study was carried out at Kurdistan, Erbil, Medicina medical center, and Rizgary general hospital from January 2021 to
... Show More
Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show More