Objectives: Osteoporosis (OP) is a systemic skeletal disorder characterized with bone mass loss and microstructure, resulting in fragility fractures. Continued secretion of Osteopontin (OPN), osteonectin (ON), osteocalcin (OCN), Parathyroid hormone (PTH) and Ca+2 lead to bone remodeling disorders, followed by bone loss and osteoporosis (OP). The current study aims to investigate the biochemical proteins OPN, OCN, and ON in postmenopausal women with osteoporosis and determine whether we could use them as good indicators for OP diagnostics. Materials and Methods: Case- control study carried out between December 2022 and July 2023. OP disease was confirmed among 108 Iraqi postmenopausal women randomly selected from different Iraqi hospitals, Baghdad, Iraq. Their ages ranged between 45 and 70 years. According to DEXA scan results 70 samples were OP +ve results, while 40 samples were -ve (healthy control). Blood samples collected from all participants in order to assess the levels of Ca+2, PTH, OPN, OCN, and ON by employing the ELISA technique. Results: High significant increase (P≤0.01) detected in PTH, OPN, and OCN serum levels, whereas, a significant decrease in Ca+² and ON, in OP patients as a comparison to control group. Conclusion: OPN, OCN, and ON measurements are accessible, inexpensive, and easy to use and could be considered a good indicators for OP diagnostics; beside to a DEXA scan as a sensitive monitoring indicator for early detection of osteoporosis.
Purpose: To compare the central corneal thickness (CCT),minimum corneal thickness (MCT) and corneal power measured using theScheimpflug-Placido device and optical coherence tomography (OCT) in healthy eyes. Study Design: Descriptive observational. Place and Duration of Study: Al-Kindy college of medicine/university of Baghdad, from June 2021 to April 2022. Methods: A total of 200 eyes of 200 individuals were enrolled in this study. CCT and MCT measurements were carried out using spectral-domain optical coherence tomography (Optovue) and a Scheimpflug-Placido topographer (Sirius).The agreement between the two approaches was assessed using Bland-Altman analysis in this study. Results: Mean age was 28.54 ± 6.6 years, me
... Show MoreThe high cost of chemical analysis of water has necessitated various researches into finding alternative method of determining portable water quality. This paper is aimed at modelling the turbidity value as a water quality parameter. Mathematical models for turbidity removal were developed based on the relationships between water turbidity and other water criteria. Results showed that the turbidity of water is the cumulative effect of the individual parameters/factors affecting the system. A model equation for the evaluation and prediction of a clarifier’s performance was developed:
Model: T = T0(-1.36729 + 0.037101∙10λpH + 0.048928t + 0.00741387∙alk)
The developed model will aid the predictiv
... Show MoreThis work aims to study the exploding copper wire plasma parameters by optical emission spectroscopy. The emission spectra of the copper plasma have been recorded and analyzed The plasma electron temperature (Te), was calculated by Boltzmann plot, and the electron density (ne) calculated by using Stark broadening method for different copper wire diameter (0.18, 0.24 and 0.3 mm) and current
of 75A in distilled water. The hydrogen (Hα line) 656.279 nm was used to calculate the electron density for different wire diameters by Stark broadening. It was found that the electron density ne decrease from 22.4×1016 cm-3 to 17×1016 cm-3 with increasing wire diameter from 0.18 mm to 0.3 mm while the electron temperatures increase from 0.741 to
Inelastic magnetic electron scattering M1 at Ex =10.23 MeV form factors in Ca-48 have been investigated. The fp shell model space with four orbits and eight neutrons have been considered and FPD6 has been selected between 32 model space effective interactions to generates the model space vectors for the M1 transition with excitation energy Ex =10.23 MeV and for constructing OBDM. Discarded space (core and higher configuration orbits) has been included through the first order perturbation theory to couple the partice-hole pair of excitation in the calculation of the total M1 form factor and regarding the realistic interaction M3Y as a core polarization interaction with six sets of fitting parameters. Finally the theoretical calculations h
... Show MoreThis paper presents the dynamic responses of generators in a multi-machine power system. The fundamental swing equations for a multi-machine stability analysis are revisited. The swing equations are solved to investigate the influence of a three-phase fault on the network largest load bus. The Nigerian 330kV transmission network was used as a test case for the study. The time domain simulation approach was explored to determine if the system could withstand a 3-phase fault. The stability of the transmission network is estimated considering the dynamic behaviour of the system under various contingency conditions. This study identifies Egbin, Benin, Olorunsogo, Akangba, Sakete, Omotosho and Oshogbo as the key buses w
... Show MoreThis study aims to determine the effect of x-ray radiation resulting from solar flares in high-frequency radio wave communications through the ionosphere and to study the radio blackout events that occur over Iraq, located within (38,28) latitude, and (38,49) longitude. Using X-ray data during strong X flares and radio wave absorption data across the D ionosphere for 10 years from 2012 to 2021. The study concluded that there were 43 events of x-flare, most of which were during years of high solar activity. All of these flares produced X-rays that caused a radio blackout, R3 and only 13 events affected Iraq.
Assessment the actual accuracy of laboratory devices prior to first use is very important to know the capabilities of such devices and employ them in multiple domains. As the manual of the device provides information and values in laboratory conditions for the accuracy of these devices, thus the actual evaluation process is necessary.
In this paper, the accuracy of laser scanner (stonex X-300) cameras were evaluated, so that those cameras attached to the device and lead supporting role in it. This is particularly because the device manual did not contain sufficient information about those cameras.
To know the accuracy when using these cameras in close range photogrammetry, laser scanning (stonex X-300) de
... Show MoreAbstract:
Objective: To assess old age behaviors toward cardiovascular health promotion. Find out the association between old age behaviors toward cardiovascular health promotion with certain sociodemographic characteristic and type of geriatric home.
Methodology: A descriptive study is conducted throughout the period of (April 12th 2022 to august 22nd, 2023) presented to assess of old age behaviors toward cardiovascular health promotion. Purposive sample of (140) old age were selected from males and female’s participants from public and private Geriatric Homes at Baghdad city questi
... Show MoreConcentrations and distribution of major, minor, and trace elements were
studied in thirteen sediment samples from Al-Hammar Marsh.
Multivariate statistical techniques such as Principal Component Analysis (PCA)
and Agglomerative Hierarchal Cluster Analysis (AHCA) as well as pollution
analysis such as Enrichment Factor (EF) were used to process the data and identify
the possible sources of elemental constituents in sediment samples.Results of
chemical analysis revealed that Major element mean concentrations were in the
order of Ca> Si> K> Mg> and minor elements were in the order of Al> Fe>S>Cl>
Ti> P>Mn> Sr> N and trace elements were in the order of Cr> Ni> Zr>V>Zn>