Purpose: Despite the high clinical accuracy of dynamic navigation, inherent sources of error exist. The purpose of this study was to improve the accuracy of dynamic navigated surgical procedures in the edentulous maxilla by identifying the optimal configuration of intra-oral points that results in the lowest possible registration error for direct clinical implementation. Materials and methods: Six different 4-area configurations were tested by 3 operators against positive and negative controls (8-areas and 3-areas, respectively) using a skull model. The two dynamic navigation systems (X-Guide® and NaviDent®) and the two registration methods (bone surface tracing and fiducial markers) produced four registration groups. The accuracy of the registration was checked at the frontal process of the zygoma. Intra- and inter- operator reliability for each registration group were reported. Multiple comparisons were conducted to find the best configuration with the minimum registration error. Results: Ranking revealed one configuration in the tracing groups (Conf.3) and two configurations in the fiducial groups (Conf.3 and Conf.5) that had the best accuracy. When the inferior surfaces of the zygomatic buttress were excluded, fiducial registration produced better accuracy with both systems (p 0.006 and <0.0001). However, tracing 1 cm areas at these surfaces bilaterally resulted in similar registration accuracy as placing fiducial markers there (p 0.430 and 0.237). NaviDent® performed generally better (p 0.049, 0.001 and 0.002) albeit having a wider margin of uncertainty in the obtained values. Changing the distribution of the 4 tracing areas or fiducial markers had a less pronounced effect with X-Guide® than with the NaviDent® system. Conclusion: For edentulous maxillary surgeries, 4 fiducial markers placed according to configuration 3 or 5 result in the lowest registration error. Where implants are being placed bilaterally, an additional 2 sites may reduce the error further. For bilateral zygomatic implant placement, it is optimal to place 2 fiducials on the inferior surfaces of the maxillary tuberosities, other 2 on their buccal surfaces, and 2 on the anterior labial surface of the alveolar bone. Utilising the inferior zygomatic buttress is recommended over the inferior maxillary tuberosities in other types of maxillary surgeries.
Background: This study was performed to compare the marginal fit changes and facture resistance of metal ceramic crowns constructed from Ceramill Sintron metal coping veneered with three different porcelain veneering materials (Vita Master Koromikos VMK, Willi Geller Creation CC and GC initial MC), also to evaluate the influence of thermocycling on load at fracture. Materials and Methods: Master brass die was scanned ,then metal coping was designed and milled from Ceramill Sintron blank to get 60 metal copings, then divided randomly into three groups(20 sample), then veneered with porcelain: VITA, Creation or GC. The marginal gaps were measured before and after porcelain veneering then marginal fit changes was calculated. Fracture resist
... Show MoreWe present a simple model of charge transfer current through sensitizer N3 molecule contact to TiO2 and ZnO semiconductors to calculate the charge transfer current. The model underlying depends on the fundamental parameters of the charge transfer reaction and it is based on the quantum transition theory approach. A transition energy, driving energy and potential barrier have been taken into account charge transfer current at N3 / TiO2 and N3 / ZnO devices with wide polarity solvents Acetic acid, 2-Methoxyethanol, 1-Butanol, Methyl alcohol, chloroform, N,N-Dimethylacetamide and Ethyl alcohol via the quantum donor-acceptor system.The effects of the transition energy and potential barrier are computed and discussion on charge transfer current.
... Show MoreWell integrity is a vital feature that should be upheld into the lifespan of the well, and one constituent of which casing, necessity to be capable to endure all the interior and outside loads. The casing, through its two basic essentials: casing design and casing depth adjustment, are fundamental to a unique wellbore that plays an important role in well integrity. Casing set depths are determined based on fracturing pressure and pore pressure in the well and can usually be obtained from well-specific information. Based on the analyzes using the improved techniques in this study, the following special proposition can be projected: The selection of the first class and materials must be done correctly and accurately in accordance with
... Show MoreRecently a large number of extensive studies have amassed that describe the removal of dyes from water and wastewater using natural adsorbents and modified materials. Methyl orange dye is found in wastewater streams from various industries that include textiles, plastics, printing and paper among other sources. This article reviews methyl orange adsorption onto natural and modified materials. Despite many techniques available, adsorption stands out for efficient water and wastewater treatment for its ease of operation, flexibility and large-scale removal of colorants. It also has a significant potential for regeneration recovery and recycling of adsorbents in comparison to other water treatment methods. The adsorbents described herein were
... Show MorePositron annihilation lifetime (PAL) technique has been employed to
study the microstructural changes of polyurethane (PU), EUXIT 101
and epoxy risen (EP), EUXIT 60 by Gamma-ray irradiation with the
dose range (95.76 - 957.6) kGy. The size of the free volume hole and
their fraction in PU and EP were determined from ortho-positronium
lifetime component and its intensity in the measured lifetime spectra.
The results show that the irradiation causes significant changes in the
free volume hole size (Vh) and the fractional free volume (Fh), and
thereby the microstructure of PU and EP. The results indicate that
the γ-dose increases the crystallinity in the amorphous regions of PU
and increas
Bilosomes are nanocarriers that contain bile salts in their vesicular bilayer, thereby enhancing their flexibility and durability in the gastrointestinal tract. Unlike conventional vesicular systems they provide distinct advantages such as streamlined manufacturing procedures, cost efficiency, and improved stability. The main objective of this study was to attain a comparison of the pharmacokinetic parameters of nisoldipine (NSD) after administering an ordinary NSD suspension and an NSD-loaded bilosome suspension. The study used 60 Swiss albino rats weighing 200±15 g and divided into two groups (n=30 each). A dose of 2.2 mg/kg of NSD was administered from the ordinary NSD suspension to the rats of the first group and the same dose
... Show MoreThis paper describes the development of a simple spectrophotometric determination of bismuth III with 4-(2-pyridylazo) resorcinol (PAR) in aqueous solution in the presence of cetypyridinium chloride surfactant at pH 5 which exhibits maximum absorption at 532 nm. Beer's law is obeyed over the range 5-200 µg/25 mL. i.e. 0.2-8 ppm with a molar absorptivity of 3×104 l.mol-1.cm-1 and Sandell's sensitivity index of 0.0069 µg.cm-2. The method has been applied successfully in the determination of Bi (III) in waters and veterinary preparation.
Well integrity is a vital feature that should be upheld into the lifespan of the well, and one constituent of which casing, necessity to be capable to endure all the interior and outside loads. The casing, through its two basic essentials: casing design and casing depth adjustment, are fundamental to a unique wellbore that plays an important role in well integrity. Casing set depths are determined based on fracturing pressure and pore pressure in the well and can usually be obtained from well-specific information. Based on the analyzes using the improved techniques in this study, the following special proposition can be projected: The selection of the first class and materials must be done correctly and accurately in accordance with the
... Show More