Preferred Language
Articles
/
Zubc7ZwBmraWrQ4da1FI
The parametric analysis of corrosion rate of carbon steel in sulfuric acid and corrosion inhibition using indole
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Sat Oct 03 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of corrosion behavior of bioceramics coated commercially pure titanium and Ti-6Al-4V alloy
...Show More Authors

Background: This study report the corrosion behavior of commercially pure titanium and Ti-6Al-4V alloy samples without coating and with hydroxyapatite, partial stabilized zirconia and mixture of partial stabilized zirconia and hydroxyapatite coating and comparison between them through electrochemical polarization tests in 37 0 C Hank's solution. Materials and methods: Electrophoretic deposition technique (EPD) was used to achieve the coating from each one of three types of the coating materials (HAP, PSZ and mixture of 50% HAP and 50%PSZ) on Cp Ti and Ti-6Al-4V alloy samples. The electrochemical corrosion test was performed when samples were exposed to Hank's solution prepared in the laboratory and the polarization potential, corrosion rate

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 03 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of metal ions release and corrosion potential from different bracket archwire combinations (An in vitro study)
...Show More Authors

Background: Esthetic treatment is the options of patient seeking orthodontic treatment. Therefore this study was conducted to measure the concentration of Aluminum, Nickel, Chromium and Iron ions released from combination of monocrysralline brackets with different arch wires immersed in artificial saliva at different duration, to evaluate the corrosion point on different parts of the orthodontic appliances before and after immersion in artificial saliva, and to evaluate the corrosion potential of each group of the orthodontic appliances. Material and methods: Eighty orthodontic sets prepared. Each set represents half fixed orthodontic appliance, from the central incisor to the first molar, for the maxillary arch, each set consisted of molar

... Show More
View Publication Preview PDF
Publication Date
Tue Apr 10 2018
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci.
Effect of Scan Rate and pH on Determination Amoxilline Using Screen Printed Carbon Electrode Modified with Functionalized Graphene Oxide
...Show More Authors

Graphene oxide GO was functionalized with 4-amino, 3-substituted 1H, 1, 2, 4 Triazole 5(4H) thion (ASTT) to obtain GOT. GOT characterized by FT-IR, XRD.via modification of the working electrode of the SPCE with the prepared nanomaterial (GOT) the effect of scan rate and pH on the determination of Amoxilline (AMOX) was studied using cyclic voltammetry. AMOX show various responses at pH ranging from 2 to 7 and also was observed sharp increase in the oxidation peaks in the pH 3. The formal potential (midpoint) for AMOX was highly pH-dependent. From the effect of scan rate, surface coverage concentration Γ of electroactive species the values of the electron transfer coefficient and the electron transfer constant rate ket was obtained as 5.39×

... Show More
Preview PDF
Publication Date
Tue Mar 19 2019
Journal Name
Al-khwarizmi Engineering Journal
Optimization of Material Removal Rate and Temperature in Magnetic Abrasive Finishing Process for Stainless Steel 304
...Show More Authors

The effect of the magnetic abrasive finishing (MAF) method on the temperature rise (TR), and material removal rate (MRR) has been investigated in this paper. Sixteen runs were to determine the optimum temperature in the contact area (between the abrasive powder and surface of workpiece) and the MRR according to Taguchi orthogonal array (OA). Four variable technological parameters (cutting speed, finishing time, working gap, and the current in the inductor) with four levels for each parameter were used, the matrix is known as a L16 (44) OA. The signal to noise ratio (S/N) ratio and analysis of the variance (ANOVA) were utilized to analyze the results using (MINITAB17) to find the optimum condition and identify the significant p

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 13 2017
Journal Name
Al-khwarizmi Engineering Journal
Shot Peening Time Effect on Corrosion Behaviors of Al Alloy 2024-T3
...Show More Authors

In this study many specimen s were prepared from 2024-T3 Aluminum alloy for corrosion test by the dimensions of (15*15*3) mm according to ASTM G71-31 and then subjected to shot peening process at different time (15, 30, 45) minutes using steel ball having a diameter of 2.75 mm and Rockwell Hardness of 55RC to induce compressive residual stress which were measured using X-Ray diffraction method, surface roughness and   hardness were tested before and after peening. Electrochemical corrosion test by Tafel extrapolation method was carried out in an environment of 3 .5% NaCl solutions (sea water) where Corrosion rate calculated using Tafle equation.

The obtained results show a favorable influence of SP treatment

... Show More
View Publication Preview PDF
Publication Date
Fri Aug 31 2018
Journal Name
International Journal Of Advanced Research
PMMA-TIO2 NANOCOMPOSITE COATING ON COPPER SUBSTRATE FOR CORROSION PROTECTION.
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Sat Apr 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Estimation & Analysis Relationship between Growth rate GDP and Unemployment Rate In Iraqi Economic in Period (1990-2014)
...Show More Authors

It reflects the gross domestic product in any country total output of goods and services by the size of the country's citizens and foreign residents during the period of the year and reflect the contribution of the commodity sectors of the economy and the distribution and service in the composition of output. And gross domestic product in Iraq as an indicator dominated in the composition of oil output, along with the contribution of the service sector, as the gross domestic product is the output of a yield lien   and subjected GDP in Iraq to a series of declines succession due to vibrations of the oil market during the economic blockade on the one hand and stop imported production inputs, lack of arriving in commodity s

... Show More
View Publication
Crossref
Publication Date
Sun Sep 06 2009
Journal Name
Baghdad Science Journal
Influence of Immersion Period on the Corrosion Behavior of Heat Treated Biomedical Alloy Ti -5Al - 2.5Fe
...Show More Authors

Heat treatment by solid solution method in the ?+? phase region was used at 970°C for Ti-5Al-2.5Fe alloy. The specimens cooled under different cooling media [water quenched (WQ), air cooled (AC) and furnace cooled (FC)], and subsequently aged at 550°C for 4 hours. Five specimens from each treatment were immersed in simulated body fluid SBF for a period of time (3 months). The dependence of corrosion rate on compositional variation in the phases resulted from various type of cooling rates are discussed based on immersion tests. The EDXA results show the precipitation of phosphate and calcium compounds on the alloy after 3 months of immersion in blood plasma solution forming a bone-like apatite, which enhanced the alloy biocompatibility ma

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jul 01 2019
Journal Name
Iop Conference Series: Materials Science And Engineering
Corrosion protection of pure titanium implant by electrochemical deposition of hydroxyapatite post-anodizing
...Show More Authors

In this study, a Hydroxyapatite (HA) coating was prepared on a titanium implant by an electrochemical deposition process. The titanium pre-treatment by anodizing in 1.65 mol/L sulfuric acid with (10V) at room temperature. The deposition was all conducted at a constant voltage of 6.0 V, for 1 h at room temperature. The coatings thus prepared were characterized with Fourier transform infrared spectroscopy (FTIR) and thickness of the coated layer.The electrochemical deposition of HA occurred on the titanium as a cathode. Coated titanium by HA after anodizing revealed a good corrosion protection efficiency even at a temperature ranged (293-323) K in artificial saliva. Activation energy and pre-exponential factor (kinetic parameters) were calcul

... Show More
View Publication Preview PDF
Scopus (14)
Scopus
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Effect of Hydroxyapatite Coatings on Corrosion Behavior for Biotype 316L SS Used in Orthopaedic Applications
...Show More Authors

Electrochemical corrosion of hydroxyapatite (HAP) coated performance depends on various parameters like applied potential, time, thickness and sintering temperature. Thus, the optimum parameters required for the development of stable HAP coatings was found by using electrophoretic deposition (EPD) technique. This study discusses the results obtained from open circuit potential-time measurements (OCP-time), potentiodynamic polarisation and immersion tests for all alloy samples done under varying experimental conditions, so that the optimum coating parameters can be established. The ageing studies of the coated samples were carried out by immersing them in Ringer’s solution for a period of 30 days indicates the importance of stable HAP c

... Show More
View Publication Preview PDF
Crossref