This article presents the results of an experimental investigation of using carbon fiber–reinforced polymer sheets to enhance the behavior of reinforced concrete deep beams with large web openings in shear spans. A set of 18 specimens were fabricated and tested up to a failure to evaluate the structural performance in terms of cracking, deformation, and load-carrying capacity. All tested specimens were with 1500-mm length, 500-mm cross-sectional deep, and 150-mm wide. Parameters that studied were opening size, opening location, and the strengthening factor. Two deep beams were implemented as control specimens without opening and without strengthening. Eight deep beams were fabricated with openings but without strengthening, while the other eight deep beams were with openings in shear spans and with carbon fiber–reinforced polymer sheet strengthening around opening zones. The opening size was adopted to be 200 × 200 mm dimensions in eight deep beams, while it was considered to be 230 × 230 mm dimensions in the other eight specimens. In eight specimens the opening was located at the center of the shear span, while in the other eight beams the opening was attached to the interior edge of the shear span. Carbon fiber–reinforced polymer sheets were installed around openings to compensate for the cutout area of concrete. Results gained from the experimental test showed that the creation of openings in shear spans affect the load-carrying capacity, where the reduction of the failure load for specimens with the opening but without strengthening may attain 66% compared to deep beams without openings. On the other hand, the strengthening by carbon fiber–reinforced polymer sheets for beams with openings increased the failure load by 20%–47% compared with the identical deep beam without strengthening. A significant contribution of carbon fiber–reinforced polymer sheets in restricting the deformability of deep beams was observed.
Several directional wells have been drilled in Majnoon oilfield at wide variation in drilling time due to different drilling parameters applied for each well. This technical paper shows the importance of proper selection of the bit, Mud type, applied weight on Bit (WOB), Revolution per minute (RPM), and flow rate based on the previous wells drilled. Utilizing the data during drilling each section for directional wells that's significantly could improve drilling efficiency presented at a high rate of penetration (ROP). Based on the extensive study of three directional wells of 35 degree inclination (MJ-51, MJ-52, and MJ-54) found that the applied drilling parameters for MJ-54 and the bit type within associated drilling parameters to drill
... Show More: Partial purification of phosphoenolpyruvate carboxykinase (PEPCK) from type 2 diabetic patients sera take place using some purification steps such as participation with ammonium sulphate (55-80%) and filtered through dialysis, then ion exchange chromatography by DEAE sepharose anion column, gel filtration chromatography by sephadex G-100 column. In ion exchange step, there are four peak are obtained, the highest enzyme activity obtained by (0.4 M Nacl) with purification fold (2.18), yield (44.3) of enzyme and specific activity (13.5) mg/ng, which obtained a single peak by gel filtration chromatography, the degree of purification (5.34) fold, yield of enzyme (20%) with specific activity (33.109mg/ng). The purified enzyme had an optimum tem
... Show MoreBackground: The base of the denture is largely responsible for providing the prosthesis with retention, stability, and support by being closely adapted to the oral mucosa. However; the process of bone resorption is irreversible and may lead to an inadequate fit of the prosthesis; this can be overcome by relining. Materials and methods: Acrylic based soft denture liner is prepared by preparing polymer from purified methylmethacrylate monomer with (10-2) initiator and (30%) dibutylphthalate plasticizer concentrations. Biological properties were evaluated in comparison with the control material through subcutaneous specimens' implantation in the New Zealand rabbits. Excisional biopsies were taken after (1, 3, days 1, 2, 3, 4 weeks) period. Mic
... Show Moreالحمد الله أولا واخرا وبعد .. إن الواقع الذي عايشه الناس في ظل دولة المسلمين منذ إقامة دولة الإسلام بعد بعثة الرسول الكريم (صلى الله عليه وسلم ) في المدينة ولأكثر من أربعة عشر قرنا نرى إنه عاش في كنف هذه الدولة الكبيرة من بلاد الصين شرقا وإلى وسط أوربا وجنوب فرنسا غربا العشرات من الملل و الأديان والأجناس وممن لا يدينون بالإسلام وهم كما تحفظ لهم دولة الإسلام منهم وعيشهم الرغيد فهم يمارسون شعائرهم وطقوسهم الديني
... Show MoreBCl3 is toxic gas and its detection is of great importance. Thus, here, B3LYP, M06-2X, and B97D density functionals are utilized for probing the effect of decorating Zn, Cd, and Au on the sensing performance of an AlP nano-sheet (AlPNS) in detecting the BCl3. We predict that the interaction of pure AlPNS with BCl3 is physisorption, and the sensing response (SR) of AlPNS is approximately 9.2. The adsorption energy of BCl3 changes from −4.1 to −18.8, −19.1, and −19.5 kcal/mol by decorating the Zn, Cd, and Au metals into the AlPNS surface, respectively. Also, the corresponding SR meaningfully rises to 40.4, 59.0, and 80.9, indicating that by increasing the atomic number of metals, the sensitivity of metal decorated AlPNS (metal@AlPNS)
... Show MoreAbstract
This study is aim to :
- Put a standard to evaluate the altruistic behavior in kindergarten children.
- Know level of the altruistic behavior in the kindergarten children according to their mother "s points of view.
- Know the level of the altruistic behavior in the kindergarten children according to their teacher "s points of view.
- The differences in the level of altruistic behavior in kindergarten children between their mothers & teachers points of view.
The sample consists of (120) children of kindergarten children in Baghdad. The researcher has built a to
... Show MoreTherapeutically and prophylactically using Microspheres containing doxycycline isolated from shell of shrimp. Low molecule weight poly lactic acid was prepared. In this study, Poly lactic acid (PLA)/ poly vinyl alcohol (PVA)/poly ethyleneglycol(PEG) loading doxycycline blend solutions was prepared. Also Poly lactic acid (PLA)-Tannin blend via solvent evaporation method was prepared. Microspheres of chitosan/gelatin microsphere loading doxycycline was prepared by emulsion crosslinking technique. Both microsphere and blends were characterized by Fourier transform infrared (FTIR) spectrophotometer. The FTIR spectra were shown distinguish bands. The in vitro release of doxcycline from its matrix at pH 7 was studied. The prophylactic
... Show More