This study investigates the levels of gaseous and particulate pollutants (PM2.5, PM10, CO, and CO₂) emitted during charcoal-grilling activities in five selected restaurants in the Al-Karkh district of Baghdad, with a focus on their environmental and health implications. Developing countries, including Iraq, face severe pollution-related challenges exacerbated by inefficient combustion processes inherent to traditional cooking practices. Restaurants that rely on charcoal grilling are a significant source of both indoor and outdoor air pollution, posing acute and chronic health risks to workers and patrons. This research documented measured amounts of pollutants released from burning coal using two types of particulate matter (PM2.5; PM10) by checking each sample for the amount present during specific times (both day and night) over nine workdays in December 2024. Data indicate that very often, PM2.5 and PM10 measurements are substantially greater than the 24-hour guideline values set by both the World Health Organization (WHO) and the US Environmental Protection Agency (US EPA) -- especially on evening peak hours, with maximums of 211 µg/m³ and 212.8 µg/m³, respectively. Carbon dioxide levels were found to be well over 900 parts per million (ppm) at most of the sites checked, indicating very poor air quality from insufficient ventilation, and carbon monoxide (CO) levels were consistently over 35 ppm and as high as 83.0 ppm at night - which can lead to headaches, dizziness, problems with thinking/working, and if exposed to this for an extended time, heart disease. Temperature and relative humidity were both found to be in a thermally good zone; however, relative humidity was found to be 60 percent or more, which adds to increased health problems associated with the pollutants from burning coal, due to a much higher risk of growth of microorganisms. The researchers believe that there is a critical need to put in place effective pollution control measures; that high-efficiency exhaust systems need to be put in place; and there should be a collaborative effort by governmental bodies and restaurant owners to develop strong, enforceable policies for regulating emissions from burning coal and protecting public health in the food-service sector of Baghdad.
In the present study the radon concentration was measured in indoor places by the RAD7 (radon detector) was in some locations at Al-Tuwaitha nuclear site and some surrounding areas for the duration from 13/10/2016 to 2/1/2017 and the measurement of the indoor radon concentration ranged from (4.96±4.4 to 102±25) Bq/m3. The high value of radon has been found at decommissioning directorate /emergency room, which is lower than the action value recommended by the Environmental Protection Agency (EPA) which is (148 Bq/m3) while the lowest value has been founded in central laboratories directorate \ models room. These values were used to calculate the annual effective dose and the health risks for cells bronchial which caused by the inhalatio
... Show MoreRoald Dhal's is a prominent British short story writer who presented a fictional world full of contradictions and ironies. It is also full of double meanings where things are not what they appear to be and where meaninglessness is a prominent component. Dahl's world is also colored with blackness and grotesqueness; full of comedy that makes you shiver instead of laugh and characters who invite a sneak peek into a different side, a dark side of human nature. Dahl's themes are various and gripping but usually revolve around the triangle that frames his fiction: violence, humour, and absurdity. What seems to be a prominent and recurrent theme that intersects with every element in this triangle is revenge. In one story after another Dahl pre
... Show MoreIn this paper, an experimental analysis of conventional air-cooled and microchannel condensers in automotive vapor compression refrigeration cycle concerning heat transfer coefficient and energy using R134a as a refrigerant was presented. The performance of two condensers and cycles tested regarding ambient temperature which it was varied from 40oC to 65oC, while the indoor temperature and load have been set to be 23oC and 2200 W respectively. Results showed that the microchannel condenser has 224 % and 77 % higher refrigerant side and air side heat transfer coefficient respectively than the coefficients of the conventional condenser. Thus, the COP, in case of using the microchannel
... Show MoreHemorrhoids are one of the most common surgical conditions. The hemorrhoid may cause symptoms that are: bleeding, pain, prolapse, itching, spoilage of feces, and psychologic discomfort. There are many methods for treatment of hemorrhoid like, medical therapy, rubber band ligation, electerocoagulation, stapled hemorrhoidpexy, photocoagulation, sclerothereapy, doppler guided artery ligation, Cryosurgery, and surgery. All methods for treatment of hemorrhoids have advantages, disadvantages, and limitations. Conventional haemorrhoidectomy was the traditional operation for the treatment of hemorrhoids. But recently other modalities of treatment had been used as an alternative operations including CO2 laser haemorrhoidectomy. This work aims to
... Show MoreDoppler broadening of the 511 keV positron annihilation ??? ? was used to estimate the concentration of defects ?? different deformation levels of pure alnminum samples. These samples were compressed at room temperature to 15, 22, 28, 38,40, and 75 % thickness reduction. The two-state ^sitron-trapping model has been employed. 'I he s and w lineshape parameters were measured using high-resolution gamma spectrometer with high pure germanium detector of 2.1 keV resolution at 1.33 MeV of 60Co. The change of defects concentration (Co) with the deformation level (e) is found to obey an empirical formula of the form Cd - A £ B where A and ? are positive constants that depend mainly on the deformation procedure and the temperature at which the def
... Show MoreMonitoring and analysing of the vertical deformations or the settlements of the structures is one of the main research fields in geodetic applications, which is considered a precise periodic measurement, made at different epochs to investigate these deformations on heavy structures.
In this research, the deformation measurements were carried out on one of Baghdad University buildings,” Building of Computers Department” of dimensions (70.0 * 81.3 m.). Due to some cracks observed in their walls, it was necessary to monitor the vertical displacement of this building at some particular monitoring points by constructing a vertical network and measured in different epochs. The first epoch (zero epoch) was carried out in April 2006, the
In the present work, a set of indoor Radon concentration measurements was carried out in a number of rooms and buildings of Science College in the University of Mustansiriyah for the first time in Iraq using RAD-7 detector which is an active method for short time measuring compared with the passive method in solid state nuclear track detectors (SSNTD's). The results show that, the Radon concentrations values vary from 9.85±1.7 Bq.m-3 to 94.21±34.7 Bq.m-3 with an average value 53.64±26 Bq.m-3 which is lower than the recommended action level 200-300 Bq/m3 [ICRP, 2009].
The values of the annual effective dose (A.E.D) vary from 0.25 mSv/y to 2.38 mSv/y, with an average value 1.46±0.67 mSv/y which is lower than the recommended the rang
Renewable energy technology is growing fast especially photovoltaic (PV) system to move the conventional electricity generation and distribution towards smart grid. However, similar to monthly electricity bill, the PV energy producers can only monitor their energy PV generation once a month. Any malfuntion in PV system components may reduce the performance of the system without notice. Thus, developing a real-time monitoring system of PV production is very crucial for early detection. In addition, electricity consumption is also important to be monitored more frequently to increase energy savings awareness among consumers. Hardware based Internet-of-Thing (IoT) monitoring and control system is widely used. However, the implementation of
... Show MoreIn this paper , the CO2 laser receiver system is designed and studied, with wavelength laser 10.6 ?m in room temperature , and to evaluate the performance and discussion it via the package of optical design (ZEMAX), from its output the Spot Diagram is measured through RMS ,and from the Ray fan plot , the aberrations is found which is the normal error for the best focus named (under corrected ) , the other output was the Geometric Encircled Energy in the spot diagram . and found that the radius of spot diagram at 80% (R80%) from the total energy ,and focal shift .The designed system have high efficiency and low cost .