Preferred Language
Articles
/
Xhd-P5ABVTCNdQwCPoVY
Synthesis, Structure Determination and Biological Study of Some Complexes of New Ligand Derived from L-ascorbic Acid
...Show More Authors

2,2'-(1-(3,4-bis(carboxydichloromethoxy)-5-oxo-2,5-dihydrofuran-2-yl)ethane-1,2-diyl)bis(oxy)bis(2,2-dichloroacetic acid) a derivative of L-ascorbic acid was prepared by reaction of L-ascorbic acid with trichloroacetic acid (1:4) ratio, in the presence of potassium hydroxide. A series of new metal complexes of this ligand were prepared by a reaction with the chlorides of Cd(II), Co(II), Ni(II), Cu(II) and Zn(II). The new ligand and its complexes were identified by C.H.N., IR, UV-visible spectra, Thermogravimetric analysis (TGA), as well as 1H, 13C-NMR and Mass spectra for ligand L. The complexes were also identified by molar conductance, atomic absorption, magnetic susceptibility and X-ray diffraction for Cu (II) complex. FT-IR spectra of complexes suggest coordination occurs through the (COO- ) as a bidentates bonding mood. Elemental analyses of the all complexes suggest that the metal to ligand ratio is 2:1. The complexes were expected to be octahedral geometry. Antibacterial activity of the L and complexes were tested against different kinds of bacteria.

Publication Date
Sun Jun 21 2020
Journal Name
Baghdad Science Journal
Spectrophotometer Determination of Cefixime in pure form and pharmaceutical preparation by Using Cloud point Extraction
...Show More Authors

Two simple methods spectrophotometric were suggested for the determination of Cefixime (CFX) in pure form and pharmaceutical preparation. The first method is based without cloud point (CPE) on diazotization of the Cefixime drug by sodium nitrite at 5Cº followed by coupling with ortho nitro phenol in basic medium to form orange colour. The product was stabilized and measured 400 nm. Beer’s law was obeyed in the concentration range of (10-160) μg∙mL-1 Sandell’s sensitivity was 0.0888μg∙cm-1, the detection limit was 0.07896μg∙mL-1, and the limit of Quantitation was 0.085389μg∙mL-1.The second method was cloud point extraction (CPE) with using  Trtion X-114 as surfactant. Beer

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Mon Oct 15 2018
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
STUDY OF THE EFFECT OF MAGNETIC FIELD POLES ON THE GROWTH OF Staphylococcus AND Streptococcus ISOLATED FROM TOOTH DECAY: STUDY OF THE EFFECT OF MAGNETIC FIELD POLES ON THE GROWTH OF Staphylococcus AND Streptococcus ISOLATED FROM TOOTH DECAY
...Show More Authors

The study aimed to determine the impact of energy for the north and south magnetic poles on the the growth of bacteria isolated from cases of tooth decay, 68 swabs were collected from surfaces of faulty tooth, the detected of Staphylococcus aureus

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 30 2025
Journal Name
Gsc Biological And Pharmaceutical Sciences
A new record of North African catfish Clarias gariepinus (Burchell, 1822) (Siluriformes: Clariidae) in Baghdad from Tigris River
...Show More Authors

A single specimen of the African catfish, Clarias gariepinus, was recorded for the first time in Baghdad, Iraq. The specimen was caught during a fish survey to document some local species in northern Baghdad (Al-Rusafa) on March 21, 2023. The total length of the specimen was 43 cm, and its weight was 590 grams. Some biometric measurements of the specimen were studied and found to be consistent with the general characteristics of the African catfish Clarias gariepinus (Burchell, 1822). It is possible that the fish entered Iraqi inland waters, specifically from the Euphrates River via Syria or from the Tigris River via Turkey.

View Publication
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
New Method for the On-Line Determination of Molybdenum Via New Microphotometric Home Mode Instrument, Using Hight Emitting Diode as a Variable Intensity Radiant Source with a Miniture Photosilicone Diode Detector for System: Molybdenum(VI)-Hydrogen Peroxide-Ammonium Solution
...Show More Authors

This research work aims to the determination of molybdenum (VI) ion via the formation of peroxy molybdenum compounds which has red-brown colour with absorbance wave length at 455nm for the system of ammonia solution-hydrogen peroxide-molybdenum (VI) using a completely newly developed microphotometer based on the ON-Line measurement. Variation of responses expressed in millivolt. A correlation coefficient of 0.9925 for the range of 2.5-150 ?g.ml-1 with percentage linearity of 98.50%. A detection limit of 0.25 ?g.ml-1 was obtained. All physical and chemical variable were optimized interferences of cation and anion were studied classical method of measurement were done and compared well with newly on-line measurements. Application for the use

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Concentration of Nitric Acid by Vacuum Distillation
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Apr 01 2023
Journal Name
Baghdad Science Journal
Carbon Nanotubes: Synthesis via Flame Fragment Deposition (FFD) Method from Liquefied Petroleum Gas
...Show More Authors

The current study uses the flame fragment deposition (FFD) method to synthesize carbon nanotubes (CNTs) from Iraqi liquefied petroleum gas (LPG), which is used as a carbon source. To carry out the synthesis steps, a homemade reactor was used. To eliminate amorphous impurities, the CNTs were sonicated in a 30 percent hydrogen peroxide (H2O2) solution at ambient temperature. To remove the polycyclic aromatic hydrocarbons (PAHs) generated during LPG combustion, sonication in an acetone bath is used. The produced products were investigated and compared with standard Multi-walled carbon nanotube MWCNTs (95%), Sigma, Aldrich, using X-ray diffraction (XRD), thermo gravimetric analysis (TGA), Raman spectroscopy, scanning el

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Tue Feb 24 2026
Journal Name
Tikrit Journal Of Administrative And Economic sciences
Determination of competency levels and auditor evaluation procedures to the international standard (ISO19011: 2018) A case study at the Ministry of Construction, Housing and General Municipalities/Audit Directorate
...Show More Authors

The current research seeks to achieve several objectives, including knowing the extent of the audit directorate of the Ministry of Construction, Housing and General Municipalities of the International Standard (ISO19011:2018) regarding determining the efficiency and evaluation of auditors and diagnosing the gap between requirements and application and knowing the reasons for not applying some of the items in the standard, starting from the problem, The field raised the following question (Does the audit directorate determine the efficiency and evaluation of auditors according to the standard ISO19011:2018?), and the importance of research lies in determining the return that can be achieved by the directorate through its application of stand

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Analytical Chemistry
A Spectrophotometric Method for Tetracycline Determination in its Bulk Powder and Pharmaceutical Formulations Using Flow Injection and Batch Procedures: a Comparative Study
...Show More Authors

A reliable and environmental analytical method was developed for the direct determination of tetracycline using flow injection analysis (FIA) and batch procedures with spectrophotometric detection. The developed method is based on the reaction between a chromogenic reagent (vanadium (III) solution) and tetracycline at room temperature and in a neutral medium, resulting in the formation of an intense brown product that shows maximum absorption at 395 nm. The analytical conditions were improved by the application of experimental design. The proposed method was successfully used to analyze samples of commercial medications and verified throughout the concentration ranges of 25–250 and 3–25 µg/mL for both FIA and batch procedures, respecti

... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
Spectrophotometric determination of Procaine penicillin in pure and pharmaceutical formulations using metol
...Show More Authors

A simple, accurate and sensitive spectrophotometric method for the determination of Procaine penicillin (PP) is described. The method is based on charge-transfer reaction of PP with metol (N-methyl-p-hydroxy aniline) in the presence of ferric sulphate to form a purple-water soluble complex ,which is stable and has a maximum absorption at 510 nm .A graph of absorbance versus concentration shows that Beer’s low is obeyed over the concentration range of 3-80 µg /ml of PP (i.e.,3-80 ppm) with a molar absorbativity of 4.945 ×103 L.mol-1.cm-1 ,Sandell sensitivity of 0.1190 µg cm-2 ,a relative error of (-1.57)-2.79 % and a standard deviation of less than 0.59 depending on the concentration of PP.The optimum conditions for full co

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Safety method, Spectrophotometric Determination of Sulfamethaxazole drug in bulk and Pharmaceutical Preparations
...Show More Authors

A simple, cheap, fast, accurate, Safety and sensitive spectrophotometric method for the determination of sulfamethaxazole (SFMx), in pure form and pharmaceutical dosage forms. has been described The Method is based on the diazotization of the drug by sodium nitrite in acidic medium at 5Cº followed by coupling with salbutamol sulphate (SBS) drug to form orange color the product was stabilized and measured at 452 nm Beer’s law is obeyed in the concentration range of 2.5-87.5 ?g ml-1 with molar absorptivity of 2.5x104 L mole-1 cm-1. All variables including the reagent concentration, reaction time, color stability period, and sulfamethaxazole /salbutamol ratio were studied in order to optimize the reaction conditions. No interferences were

... Show More
View Publication Preview PDF
Crossref