To evaluate the effectiveness of different microwave irradiation exposure times on the disinfection of dental stone samples immersed in different solutions, and its affect on the dimensional accuracy and surface porosity. Dental stone casts were inoculated with an isolate of Bacillus subtilis to examine the efficiency of microwave irradiation as a disinfection method while immersed in different solutions; water, 40% sodium chloride, or without immersion for different durations. Dimensional accuracy and surface porosity were also evaluated. Significant reduction in colony counts of Bacillus subtilis were observed after 5 minutes of microwave irradiation of immersed dental casts in water and NaCl solution. No evidence of growth was observed after 10 minutes while immersed in water or NaCl solution. Dimensional accuracy of dental stone was significantly affected by immersion in water for 5 or 10 minutes during exposure to microwave irradiation while it was insignificant affected by immersed in NaCl solution, or in dry air. The surface porosity of dental stone was significantly affected by the immersed in water and NaCl solution for 5 or 10 minutes while it was insignificantly affected by dry conditions during microwave disinfection. Immersion the dental stone casts improved the effectiveness of microwave irradiation as a disinfection method. The dimensional accuracy and surface porosity was adversely affected but within the clinical limitation.
Abstract
Although the rapid development in reverse engineering techniques, 3D laser scanners can be considered the modern technology used to digitize the 3D objects, but some troubles may be associate this process due to the environmental noises and limitation of the used scanners. So, in the present paper a data pre-processing algorithm has been proposed to obtain the necessary geometric features and mathematical representation of scanned object from its point cloud which obtained using 3D laser scanner (Matter and Form) through isolating the noised points. The proposed algorithm based on continuous calculations of chord angle between each adjacent pair of points in point cloud. A MATLAB program has been built t
... Show MoreIron oxide(Fe3O4) nanoparticles of different sizes and shapes were synthesized by solve-hydrothermal reaction assisted by microwave irradiation using ferrous ammonium sulfate as a metal precursor, oleic acid as dispersing agent, ethanol as reducing agent and NaOH as precipitating agent at pH=12. The synthesized Fe3O4 nano particles were characterized by X-ray diffraction (XRD), FTIR and thermal analysis TG-DTG. Sizes and shapes of Fe3O4 nanoparticles were characterized by Scanning Electron Microscopy (SEM), and atomic force microscopy (AFM).
OpenStreetMap (OSM), recognised for its current and readily accessible spatial database, frequently serves regions lacking precise data at the necessary granularity. Global collaboration among OSM contributors presents challenges to data quality and uniformity, exacerbated by the sheer volume of input and indistinct data annotation protocols. This study presents a methodological improvement in the spatial accuracy of OSM datasets centred over Baghdad, Iraq, utilising data derived from OSM services and satellite imagery. An analytical focus was placed on two geometric correction methods: a two-dimensional polynomial affine transformation and a two-dimensional polynomial conformal transformation. The former involves twelve coefficients for ad
... Show MoreAssessment the actual accuracy of laboratory devices prior to first use is very important to know the capabilities of such devices and employ them in multiple domains. As the manual of the device provides information and values in laboratory conditions for the accuracy of these devices, thus the actual evaluation process is necessary.
In this paper, the accuracy of laser scanner (stonex X-300) cameras were evaluated, so that those cameras attached to the device and lead supporting role in it. This is particularly because the device manual did not contain sufficient information about those cameras.
To know the accuracy when using these cameras in close range photogrammetry, laser scanning (stonex X-300) de
... Show MoreBackground: Dental caries is generally given the highest priority in national oral health services for adult populations. Yet, there is no study which has explored the impact on quality of life specifically related to dental caries in samples of dental students. The purpose of the current study was to assess the impact of caries experience on quality of life among dental students in three governorates in Iraq. Materials and Methods: This observational study included 1364 dental students aged 18–22 years old, from three governorates. Information on quality of life was obtained from a structured, self-administered questionnaire from the students who were willing to participate in the study. The data was collected, summarized and sta
... Show MoreAbstract
Nowadays, the adoption of economic unity on the accuracy of financial reporting is very important. Economic units need accurate financial reporting to be more competitive and to improve the performance. Management can also achieve financial information in real time through the application of ERP systems. This system will facilitate management to access the most up-to-date information such as planning, monitoring and evaluating the business processes of the organization to be more effective.
On the practical side, the Enterprise Resource Planning (ERP) system was applied to the General Company for Vegetable Oils to demonstrate a course in enhancing the accuracy of financial reporting.
... Show MoreBackground: We aimed to investigate the accuracy of salivary matrix metalloproteinases (MMP)-8 and -9, and tissue inhibitor of metalloproteinase (TIMP)-1 in diagnosing periodontitis and in distinguishing periodontitis stages (S)1 to S3. Methods: This study was a case–control study that included patients with periodontitis S1 to S3 and subjects with healthy periodontia (controls). Saliva was collected, and then, clinical parameters were recorded, including plaque index, bleeding on probing, probing pocket depth, and clinical attachment level. Diagnosis was confirmed by assessing the alveolar bone level using radiography. Salivary biomarkers were assayed using an enzyme-linked immunosorbent assay. Results: A total of 45 patients (15
... Show MoreThe study was aimed to determine the coordinates of the points were measured by different ways and different instruments, the most precise way using the differential global positioning system (DGPS) that will be the reference measurements in comparison, less precise way using navigator GPS. Google earth (pro.), and the other applications of GPS mobile ( Samsung and I-phone). In this research (8 points) were chosen that are occasional in location. The comparison of the different observations can give us an idea of the extent to which the accuracy of the observations differs from the different devices used in the observing, as well as through the knowledge of the best device and the best way to measure coordinates accurately t
... Show More