Preferred Language
Articles
/
Web7Z5wBmraWrQ4dVEmY
Thermal Performance of Solar Hot Water Systems Using a Flat Plate Collector of Accelerated Risers
...Show More Authors

 This study focuses on a comparison of the performance of two similar locally-fabricated solar water heaters. One of the collectors features a new design for accelerated absorber; its risers are made of converging ducts whose exit area is half that of the entrance. The other collector is a conventional absorber, with risers of the same cross sectional area along its length. Each collector is the primary part of an indirect thermosyphon circulation solar hot water system. Both collectors face south with a fixed tilt angle of 33.3

Scopus Crossref
View Publication
Publication Date
Thu Oct 29 2020
Journal Name
The 11th International Renewable Energy Congress (irec 2020)
Thermal efficiency Optimization of the evacuated tube solar water heater system by using mirror flat reflector
...Show More Authors

In this paper a comparison of the experimental of evacuated tube solar water heater systems with and without mirror flat reflector. The aim of using the reflector to improve thermal efficiency, and the data gathered which are (temperature, solar irradiation and time) for three days were compared. the results from compared data the temperature lower increase in evacuated tube solar water heater system without reflector than the temperature increase in evacuated tube solar water heater system with reflector .The results show (53, 39, 35) % for three days respectively that the evacuated tube solar water heater system with reflector has higher thermal efficiencies than the results (47, 28, 30) % for three days respectively thermal efficiencies

... Show More
View Publication
Crossref (4)
Crossref
Publication Date
Mon Mar 23 2020
Journal Name
Journal Of Engineering
Experimental Investigation of Thermal Performance of a Solar Chimney Provided with a Porous Absorber Plate
...Show More Authors

 

Experimental investigation of the influence of inserting the metal foam to the solar chimney to induce natural ventilation are described and analyzed in this work. To carry out the experimental test, two identical solar chimneys (without insertion of metal foam and with insertion of metal foam) are designed and placed facing south with dimensions of length× width× air gap (2 m× 1 m× 0.2 m). Four incline angles are tested (20o,30o,45o,60o) for each chimney in Baghdad climate condition (33.3o latitude, 44.4o longitude) on October, November, December 2018. The solar chimney performance is investigated by experimentally recording absorber pl

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Jan 04 2023
Journal Name
Frontiers In Chemestry
Thermal and flow performance analysis of a concentrated linear Fresnel solar collector with transverse ribs
...Show More Authors

This article deals with the impact of including transverse ribs within the absorber tube of the concentrated linear Fresnel collector (CLFRC) system with a secondary compound parabolic collector (CPC) on thermal and flow performance coefficients. The enhancement rates of heat transfer due to varying governing parameters were compared and analyzed parametrically at Reynolds numbers in the range 5,000–13,000, employing water as the heat transfer fluid. Simulations were performed to solve the governing equations using the finite volume method (FVM) under various boundary conditions. For all Reynolds numbers, the average Nusselt number in the circular tube in the CLFRC system with ribs was found to be larger than that of the plain abs

... Show More
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Thu Aug 31 2017
Journal Name
Journal Of Engineering
Energy Analysis of Solar Collector With perforated Absorber Plate
...Show More Authors

The thermal performance of three solar collectors with 3, 6 mm and without perforation absorber plate was assessed experimentally. The experimental tests were implemented in Baghdad during the January and February 2017. Five values of airflow rates range between 0.01 – 0.1 m3/s were used through the test with a constant airflow rate during the test day. The variation of the following parameters air temperature difference, useful energy, absorber plate temperature, and collector efficiency was recorded every 15 minutes. The experimental data reports that the increases  the number of absorber plate perforations with a small diameter is more efficient rather than increasing the hole diameter of the absorber plate with decr

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Manufacturing and Study the performance of Selective Surfaces that used in flat plate Solar Collectors
...Show More Authors

In this research an experimental study has done for testing the thermal performance of selective surfaces used in solar collectors for substrate of iron, galvanized iron and aluminum which are commercially available. The coating process for the samples has done in two ways, the electroplating and the chemical spray pyrolysis. The results of the thermal performance test of these samples are comparing with the thermal performance of a sample without paint and other paint with black paint without shines commercially available. For the electroplated samples, the performance study has done for different immersion time in plating bath, the
distance between electrical poles, the current density, and area ratio of the sample plated area to

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Sep 01 2025
Journal Name
Al-khwarizmi Engineering Journal
Impact of Design Parameters in Thermal Solar Water Storage Tank Systems: (A Review)
...Show More Authors

This work provides a historical overview of water storage tanks used for solar energy collection, with a focus on the impact of different geometric configurations on thermal performance and energy storage efficiency. The designs of cylindrical, spherical, rectangular and triangular tanks were reviewed to analyse their effects on thermal gradients, heat retention and energy storage capacity. Within the scope of nominal processes, the study primarily aimed to identify the factors influencing the choice of tank shape in terms of size, capacity and aspect ratio. Another key objective was to assess what enhances heat storage in the tank to improve thermal efficiency. Comparing cylindrical shapes to other shapes, such as spherical, rectan

... Show More
View Publication
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Engineering
Experimental Study of Electrical and Thermal Efficiencies of a Photovoltaic Thermal (PVT) Hybrid Solar Water Collector with and Without Glass Cover
...Show More Authors

Investigating the thermal and electrical gains and efficiencies influence the designed photovoltaic thermal hybrid collector (PVT) under different weather conditions. The designed system was manufactured by attaching a fabricated cooling system made of serpentine tubes to a single PV panel and connecting it to an automatic controlling system for measuring, monitoring, and simultaneously collecting the required data. A removable glass cover had been used to study the effects of glazed and unglazed PVT panel situations. The research was conducted in February (winter) and July (summer), and March for daily solar radiation effects on efficiencies. The results indicated that electrical and thermal gains increased by the incre

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Mon Oct 01 2012
Journal Name
Applied Energy
Analysis of thermal and electrical performance of a hybrid (PV/T) air based solar collector for Iraq
...Show More Authors

View Publication
Scopus (137)
Crossref (118)
Scopus Crossref
Publication Date
Mon Oct 01 2012
Journal Name
Applied Energy
Analysis of thermal and electrical performance of a hybrid (PV/T) air based solar collector for Iraq
...Show More Authors

The electrical and thermal performance of a typical single pass hybrid photovoltaic/thermal (PV/T) air collector is modeled, simulated and analyzed for two selected case studies in Iraq. An improved mathematical thermo-electrical model is derived in terms of design, operating and climatic parameters of the hybrid solar collector to evaluate its important characteristics: collector flow and heat removal factors, PV maximum power point and its temperature coefficient, and overall power and efficiency. Unlike previous PV/T thermal models, the present model is obtained with some additions and corrections in radiation and convection heat coefficients for the top loss and for the air duct with more applicable sky temperature correlation. The well

... Show More
View Publication
Scopus (137)
Crossref (118)
Scopus Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Parametric Study of Active Solar Heating Using a Pebble Bed as a Thermal Collector and Storage Unit
...Show More Authors

In this study, pebble bed as an absorber and storage material was placed in a south facing, flat plate air-type solar collector at fixed tilt angle of (45°). The effect of this material and differ- ent parameters on collector efficiency has been investigated experimentally and
theoretically. Two operation modes were employed to study the performance of the solar air heater. An inte- grated mode of continuous operation of the system during the period of (11:00 am – 3:00 pm) and non-integrated mode in which the system stored the solar energy through the day then used the stored energy during the period of (3:00 pm – 8:00 pm). The results of parametric study in case of continuous operating showed that the maximum average temperatur

... Show More
View Publication Preview PDF
Crossref (2)
Crossref