Intrusion detection systems detect attacks inside computers and networks, where the detection of the attacks must be in fast time and high rate. Various methods proposed achieved high detection rate, this was done either by improving the algorithm or hybridizing with another algorithm. However, they are suffering from the time, especially after the improvement of the algorithm and dealing with large traffic data. On the other hand, past researches have been successfully applied to the DNA sequences detection approaches for intrusion detection system; the achieved detection rate results were very low, on other hand, the processing time was fast. Also, feature selection used to reduce the computation and complexity lead to speed up the system. A new features selection method is proposed based on DNA encoding and on DNA keys positions. The current system has three phases, the first phase, is called pre-processing phase, which is used to extract the keys and their positions, the second phase is training phase; the main goal of this phase is to select features based on the key positions that gained from pre-processing phase, and the third phase is the testing phase, which classified the network traffic records as either normal or attack by using specific features. The performance is calculated based on the detection rate, false alarm rate, accuracy, and also on the time that include both encoding time and matching time. All these results are based on using two or three keys, and it is evaluated by using two datasets, namely, KDD Cup 99, and NSL-KDD. The achieved detection rate, false alarm rate, accuracy, encoding time, and matching time for all corrected KDD Cup records (311,029 records) by using two and three keys are equal to 96.97, 33.67, 91%, 325, 13 s, and 92.74, 7.41, 92.71%, 325 and 20 s, respectively. The results for detection rate, false alarm rate, accuracy, encoding time, and matching time for all NSL-KDD records (22,544 records) by using two and three keys are equal to 89.34, 28.94, 81.46%, 20, 1 s and 82.93, 11.40, 85.37%, 20 and 1 s, respectively. The proposed system is evaluated and compared with previous systems and these comparisons are done based on encoding time and matching time. The outcomes showed that the detection results of the present system are faster than the previous ones.
Background:-The Modified Alvarado Scoring System (MASS) has been reported to be a cheap and quick diagnostic tool in patients with acute appendicitis. However, differences in diagnostic accuracy have been observed if the scores were applied to various populations and clinical settings.
Objectives:- The purpose of this study was to evaluate the diagnostic value of Modified Alvarado Scoring System in patients with acute appendicitis in our setting.
Methods:-one hundre twenty eight patients ,were included in this study, admitted to Al-Kindy teaching hospital from June 2009 to June 2010. Patients’ age ranged from 8 to 56 years (21±10) they were divided into three groups; paediatrics, child bearing age females & adult males,. MAS
Background:-The Modified Alvarado Scoring
System (MASS) has been reported to be a cheap
and quick diagnostic tool in patients with acute
appendicitis. However, differences in diagnostic
accuracy have been observed if the scores were
applied to various populations and clinical settings.
Objectives:- The purpose of this study was to
evaluate the diagnostic value of Modified Alvarado
Scoring System in patients with acute appendicitis
in our setting.
Methods:-one hundre twenty eight patients, were
included in this study, admitted to Al-Kindy
teaching hospital from June 2009 to June 2010.
Patients’ age ranged from 8 to 56 years (21±10)
they were divided into three groups; paediatrics,
child bear
Low-level microbial activity due to the production of organic acids is a recognized problem during the initial phase of food waste composting. Increasing such activity levels by adjusting the pH values during the initial composting phase is the primary objective to be investigated. In this study, sodium acetate (NaoAc) was introduced as an amendment to an in-vessel composting system. NaoAc was added when the pH of the compost mixture reached a low level (pH < 5), the addition increased pH to 5.8. This had a positive effect on the degradation of organic materials i.e. the formation of methane gas compared to the results without NaoAc addition.
The results also proved that anaerobic-aerobic in-vessel composting could reduce the
... Show MoreOne of the concerns of adopting an e-voting systems in the pooling place of any critical elections is the possibility of compromising the voting machine by a malicious piece of code, which could change the votes cast systematically. To address this issue, different techniques have been proposed such as the use of vote verification techniques and the anonymous ballot techniques, e.g., Code Voting. Verifiability may help to detect such attack, while the Code Voting assists to reduce the possibility of attack occurrence. In this paper, a new code voting technique is proposed, implemented and tested, with the aid of an open source voting. The anonymous ballot improved accordingly the paper audit trail used in this machine. The developed system,
... Show MoreSolar tracking systems used are to increase the efficiency of the solar cells have attracted the attention of
researchers recently due to the fact that the attention has been directed to the renewable energy sources. Solar tracking systems are of two types, Maximum Power Point Tracking (MPPT) and sun path tracking. Both types are studied briefly in this paper and a simple low cost sun path tracking system is designed using simple commercially available component. Measurements have been made for comparison between fixed and tracking system. The results have shown that the tracking system is effective in the sense of relatively high output power increase and low cost.
In this paper, an experimental study of the thermal performance for hybrid solar air conditioning system was carried out, to investigate system suitability for the hot climate in Iraq. The system consists of vapor compression unit combined with evacuated tube solar collector and liquid storage tank. A three-way valve was installed after the compressor to control the direction flow of the refrigerant, either to the storage tank or directly to the condenser. The performance parameters were collected by data logger to display and record in the computer by using LabVIEW software. The results show that the average coefficient of performance of hybrid solar air conditioning system (R=1) was about 2.42 to 2.77 and the average p
... Show More