Water is a resource and a crucial aspect of living and surviving. In Iraq, the Tigris River is one of the most critical water sources. The present study aimed to provide an insight analysis of some water quality parameters including the microbial content of drinkable tap water and river water. Ten Water samples (T1- T10) in triplicate were collected from sampling sites -Site I (Tap water) from home water taps, supplied by the Water Filtration Station/ Al Karama Project/ Al-Karkh> 10 from Site II (R1- R10)River water from Tigris River (around or near the Water Filtration Station/ Al Karama Project) every week (from September to half of November 2022), then were immediately placed in sterile bottles and transported to Microbiology lab for the analysis. Site I, turbidity was (0.7- 6) NTU. Free Chlorine availability was 0.5- 3.5 mg/L>CFU/ mL ranged from 0 to 40 in Total Plate Count (TPC);membrane filtration method (MFM) was unsatisfactory (T1, T8,T9), other samples were satisfactory. Site II, coliform result was 5200- 9200 CFU/ 100mL;Lauryl Tryptose broth (11000–49000) MPN/100mL,;Brilliant Green Bile broth (6900–17000 MPN/100mL); EC-MUG (E. coli medium with 4-methylumbelliferyl-β-D-glucuronide) was4900- 22000 MPN/100mL and EC-Broth was 4900- 22000 MPN/100mL. m-Endo Agar LES was +ve for all samples. All Tigris River water samples , were contaminated with coliform bacteria: E. coli, C. freundii, and Sphingomonas paucimobilis (sample R2) as non-coliform. Site I were drinkable and reliable, corresponding to Iraqi and WHO typical parameters, while Site II was under standardization.
In this work the interaction of plasma jet with water and hydrogen peroxide liquids used for assisted teeth bleaching by plasma jet had been study. A homemade plasma jet system was used. The plasma jet supply by 15 W electrical power generated by high voltage power supply of 9.6 kV peak to peak and frequency of 33 kHz .this power supply generate high electric field on electrodes that would be enough to ionize the argon gas. Some important agents were study such as the effect of the Ar gas flow rates on the length of the plasma jet, the influence of plasma jet on some properties of water and two hydrogen peroxide concentrations 25 % and 30 % like pH, conductivity and liquid temperature for different exposure time. The liquids temperature
... Show MoreA comparative study was carried out on ecological and genetical adaptation of three Iraqi
freshwater snails, Physa acuta, Melanopsis buccinoidea and Melanoides tuberculata, in
respect to acute toxicity of heavy metals (Zn, Cd and Hg). Longevity are used as poisoning
tolerance criterion. LT 50 and LT 100 were determined for the studied snails at (0.5, 1, 5, and
10 ppm), for the three metals. Results indicated that Physa acuta had a higher tolerance than
Melanopsis buccinoidea and Melanoides tuberculata, which was the lower one. Previous
exposure to heavy metals in the original habitat was affecting on experimental tolerance and
no relationships of physical and chemical factors (total hardness, temperature, D. O. and
The research was conducted between 2017 and 2019 at the College of Agricultural Engineering Sciences and Laboratory of Plant Tissue Culture for Postgraduate Studies at the University of Baghdad. One experiment used a totally random design. The experiment examined the effects of PEG (Polyethylene glycol) at concentrations of 0, 2, 4, 6, and 8% on the development of three sunflower types (Ishaqi-1, Aqmar, and AL-Haja) exposed to UV-C rays for 40 minutes as a result of the growing of the juvenile peduncle outside the live body. The aim of the study was to better comprehend the physiological and biochemical changes caused by water stress on the callus of several sunfl
A simple and rapid spectrophotometric method for the determination of sulphite SO3-2 is described. The method is based on the rapid reduction of known amount of chromate CrO4-2 in the presence of sulphite in acidic medium of 2N H2SO4. The amount of excess of chromate was measured after it reactions with 1,5-diphenylcarbazide which finally gives a pink-violet, water soluble and stable complex, which exhibit a maximum absorption at 542 nm. Beer's law was obeyed in the concentration range from 0.004-6.0 µg of sulphite in a final volume of 25 ml with a molar absorbtivity of 4.64×104 l.mol-1.cm-1, Sandal's sensitivity index of 0.001724 ?g .cm-2 and relative standard deviation of ±0.55 - ±0.83 depending on the concentration level. The present
... Show MoreThe driving idea for the present work was to combine the effect of polyvinyl alcohol (PVA) as corrosion inhibitor with the distance between the anodic and cathodic elements of the galvanic cell, beside their area ratio, in scope of synergistic suppression of galvanic corrosion on Cu/Fe model couple, using weight loss method. The performance affecting galvanic corrosion process has been tested for three major factors affect the process:
1. Four PVA inhibitor concentrations were selected to be (0, 1000, 4000 and 7000 ppm) in simulated cooling water.
2. Two cathode: anode area ratios as 1:1 and 2.4:1.
3. Two distances apart cathode – anode as 3 and 7 cm.
Maximum corrosion inhibition achieved was 86% which indicates that increa
The distribution of chilled water flow rate in terminal unit is a major factor used to evaluate the performance of central air conditioning unit. In this work, a theoretical chilled water distribution in the terminal units has been studied to predict the optimum heat performance of terminal unit. The central Air-conditioning unit model consists of cooling/ heating coil (three units), chilled water source (chiller), three-way and two-way valve with bypass, piping network, and pump. The term of optimization in terminal unit ingredient has two categories, the first is the uniform of the water flow rate representing in statically permanents standard deviation (minimum value) and the second category is the maximum heat transfer rate fro
... Show More