Preferred Language
Articles
/
VhZ-L4sBVTCNdQwC9cia
Evaluating of the association between ABO blood groups and coronavirus disease 2019 (COVID-19) in Iraqi patients
...Show More Authors
Abstract<sec> <title>Background

Susceptibility to the pandemic coronavirus disease 2019 (COVID-19) has recently been associated with ABO blood groups in patients of different ethnicities. This study sought to understand the genetic association of this polymorphic system with risk of disease in Iraqi patients. Two outcomes of COVID-19, recovery and death, were also explored. ABO blood groups were determined in 300 hospitalized COVID-19 Iraqi patients (159 under therapy, 104 recovered, and 37 deceased) and 595 healthy blood donors. The detection kit for 2019 novel coronavirus (2019-nCoV) RNA (PCR-Fluorescence Probing) was used in the diagnosis of disease.

Results

Mean age was significantly increased in patients compared to controls (49.8 ± 11.7 vs. 28.9 ± 6.6 years; p < 0.001). A similar observation was made in recovered (42.1 ± 10.4 vs. 28.9 ± 6.6 years; p < 0.001) and deceased (53.6 ± 9.7 vs. 28.9 ± 6.6 years; p < 0.001) cases. The mean age was also significantly increased in deceased cases compared to recovered cases (53.6 ± 9.7 vs. 42.1 ± 10.4 years; p < 0.001). There were gender-dependent differences in COVID-19 prevalence. The percentage of COVID-19 was higher in males than in females (all cases: 59.7 vs. 40.3%; recovered cases: 55.8 vs. 44.2%). Such male-gender preponderance was more pronounced in deceased cases (67.6 vs. 32.4%). Logistic regression analysis revealed that groups AB and B + AB were significantly associated with increased risk to develop COVID-19 (OR = 3.10; 95% CI 1.59–6.05; pc = 0.007 and OR = 2.16; 95% CI 1.28–3.63; pc = 0.028, respectively). No ABO-associated risk was observed in recovered cases. On the contrary, groups A (OR = 14.60; 95% CI 2.85–74.88; pc = 0.007), AB (OR = 12.92; 95% CI 2.11–79.29; pc = 0.042), A + AB (OR = 14.67; 95% CI 2.98–72.33; pc = 0.007), and A + B + AB (OR = 9.67; 95% CI 2.02–46.24; pc = 0.035) were associated with increased risk of death in deceased cases.

Conclusions

The findings of this study suggest that group AB may be a susceptibility biomarker for COVID-19, while group A may be associated with increased risk of death.

Scopus Clarivate Crossref
View Publication
Publication Date
Wed Feb 27 2019
Journal Name
Journal Of Nano Research
A Specific NH&lt;sub&gt;3&lt;/sub&gt; Gas Sensor of a Thick MWCNTs-OH Network for Detection at Room Temperature
...Show More Authors

NH3 gas sensor was fabricated based on deposited of Functionalized Multi-Walled Carbon Nanotubes (MWCNTs-OH) suspension on filter paper substrates using suspension filtration method. The structural, morphological and optical properties of the MWCNTs film were characterized by XRD, AFM and FTIR techniques. XRD measurement confirmed that the structure of MWCNTs is not affected by the preparation method. The AFM images reflected highly ordered network in the form of a mat. The functional groups and types of bonding have appeared in the FTIR spectra. The fingerprint (C-C stretch) of MWCNTs appears in 1365 cm-1, and the backbone of CNTs observed at 1645 cm-1. A homemade sensi

... Show More
View Publication
Scopus (16)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Manganese Ions (Mn2+) from a Simulated Wastewater by Electrocoagulation/ Electroflotation Technologies with Stainless Steel Mesh Electrodes: Process Optimization Based on Taguchi Approach
...Show More Authors

This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Manganese Ions (Mn2+) from a Simulated Wastewater by Electrocoagulation/ Electroflotation Technologies with Stainless Steel Mesh Electrodes: Process Optimization Based on Taguchi Approach
...Show More Authors

This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis of variance (ANO

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sat Dec 30 2023
Journal Name
Basrah Journal Of Surgery
Can Hyaluronic acid gel enhance wound healing faster than Advanced Platelets Rich Fibrin following surgical removal of impacted mandibular third molars? A Randomized Controlled Trial
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Annals Of Tropical Medicine & Public Health
Newly developed method for determination of methyldopa drug using ammonium ceric (IV) nitrate by continuous flow injection analysis via homemade NAG-ADF-300-2 analyser
...Show More Authors

A new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n

... Show More
Crossref (2)
Crossref
Publication Date
Sat May 14 2022
Journal Name
Oral And Maxillofacial Surgery
Evaluation of crestal sinus floor elevations using versah burs with simultaneous implant placement, at residual bone height ≥ 2.0 _ &lt; 6.0 mm. A prospective clinical study
...Show More Authors

View Publication
Scopus (8)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Fri Jun 01 2018
Journal Name
Journal Of The College Of Languages (jcl)
بررسیِ حرکت¬شناختیِ افعالِ متنِ "ما زِ بالاییم و بالا می رویم" مولانا Kinetic Study of Mewlana Jalaluddin Rumi's "Mazi Balaeem we Bala Mi Roeem" Text's Verbs
...Show More Authors

چکیده­ی بحث

       به نظر می­آید که عالم هستی ، بر مسأله­ی « حرکت» استوار دارد ، و روح ، همیشه دنبال دگرگونی و تکامل و برتری می­گردد. حرکت ، همه­ی چیزها در عالم إمکان را  در بر می­گیرد. حرکت در بنیادهای فکر مولانا جای مهمی دارد .اشعار مولانا مقدار زیادی از پویایی و حرکت برخوردارست، و از آنجایی که فعل ، عنصر تکانبخش جمله ، و کانون دلالت است ، ترجیح دادیم - علاوه بر دیگر عنا

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 05 2017
Journal Name
Chemical Engineering Communications
Microwave-assisted preparation of mesoporous-activated carbon from coconut (<i>Cocos nucifera</i>) leaf by H<sub>3</sub>PO<sub>4</sub>activation for methylene blue adsorption
...Show More Authors

View Publication
Scopus (100)
Crossref (96)
Scopus Clarivate Crossref
Publication Date
Sun Mar 04 2018
Journal Name
Iraqi Journal Of Science
Assessment of ISNAG fluorimeter (Total fluorescence measurements at+ 90° & - 90° using four solar cell on each side for 100mm distance at 2mm path length) with well-known fluorescent molecules via CFIA
...Show More Authors

Two well-known fluorescent molecules: fluorescein sodium salt (FSS) and 2,7-dichloro fluorescein (DCF) were tried to prove the efficiency, trustability and repeatability of ISNAG fluorimeter by using discrete and continuous flow injection analysis modes.A linear range of 0.002-1 mmol/L for FSS and 0.003-0.7 mmol/L was for DCF, with LOD 0.0018 mmol/L and 0.002 mmol/L for FSS and DCF respectively, were obtained for discrete mode of analysis. While the continuous mode gave a linear range of 0.002-0.7 mmol/L and 0.003-0.5 mmol/L for FSS and DCF respectively, the LOD were 0.0016mmol/L and 0.0018 mmol/L for FSS and DCF respectively. The results were compared with classical method at variable λex for both fluorescent molecules at 95

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 03 2023
Journal Name
Iraqi Journal Of Science
Effect Effect Effect Effect Effect Effect Effect of Thickness on Some Physical PropertiesThickness on Some Physical PropertiesThickness on Some Physical PropertiesThickness on Some Physical PropertiesThickness on Some Physical Properties Thickness on Some
...Show More Authors

The effect of thickness variation on some physical properties of hematite α-Fe2O3 thin films was investigated. An Fe2O3 bulk in the form of pellet was prepared by cold pressing of Fe2O3 powder with subsequent sintering at 800 . Thin films with various thicknesses were obtained on glass substrates by pulsed laser deposition technique. The films properties were characterized by XRD, and FT-IR. The deposited iron oxide thin films showed a single hematite phase with polycrystalline rhombohedral crystal structure .The thickness of films were estimated by using spectrometer to be (185-232) nm. Using Debye Scherrerś formula, the average grain size for the samples was found to be (18-32) nm. Atomic force microscopy indicated that the films had

... Show More
View Publication Preview PDF