Over the years, the field of Medical Imagology has gained considerable importance. The number of neuroimaging studies conducted using functional magnetic resonance imaging (fMRI) has been exploding in recent years. fMRI survey gives to rise to large amounts of noisy data with a complex spatiotemporal correlation structure. Statistics play great role in clarifying the features of the data and gain results that can be used and explain by neuroscientists. Several types of artifacts can happen through a functional magnetic resonance imaging (fMRI) scanner Because of software or hardware problems, physical limitation or human physiologic phenomenon. Several of them can negatively affect diagnostic image goodness, and confused with various pathology. Artificial Characteristics is show in an image not found in the real actual object it is the necessary to recognize these artifacts according to a basic perception of their origin, especially those simulating pathology, as they can be sing to wrong diagnostic medical. As a result, it causes dangerous effects on the patient’s health. We discuss the study of fMRI data in this paper; we highlight important and significant problems where statistics already play a major role. It is include a sequence of programs for processing, analysing, and offer fMRI data. Of special regard to statisticians might be its use of functions from the statistical software package. The conventional methods are FSL and SPM. The most generally applied software is SPM (Statistical Parametric Mapping), which include groups of MATLAB functions for pre-processing, analysing, and display fMRI data.
The accountants are preparing the financial statements under the Monetary Unit Stability Assumption without taking into consideration the changement of prices for the monetary unit. The income statement accounts containing different items of expenses and revenues. These items are not paid or obtained at one date, because the value of monetary unit is changing from one date to another , also the financial position contains different items of current and fixed assets, also contains different items of long-term liabilities and ownership rights, the continuity of applying historical cost principle will make the financial statements misleading, The adoption of financial analyst of these statements will affects
... Show MoreIs the subject of environmental analysis of the important issues that should occupy the attention of the departments of banks in general and banks in particular, the research sample, regardless of their size and the nature of its activity, So if the current era and witnessing rapid developments and changes, making the banking environment is more complex and interconnected than ever, And it became not possible for banks to be aware and understand the external environment variables without an analysis of the various constituent elements and influential heavily in its financial and administrative,Therefore research aims to find out the relationship between the external environment and banking facilities analysis application on the Rafidain
... Show MoreThree mesoporous silica with different functional group were prepared by one-step synthesis based on the simultaneous hydrolysis and condensation of sodium silicate with organo - silane in the presence of template surfactant polydimethylsiloxane - polyethyleneoxide (PDMS - PEO). The prepared materials were characterized by Fourier transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), atomic force microscopy (AFM) and nitrogen adsorption/desorption experiments. The results indicate that the preparation of methyl and phenyl functionalized silica were successful and the mass of methyl and phenyl groups bonded to the silica structure are 15, 38 mmol per gram silica. The average diameter of the silica particles are 103.51,
... Show MoreEnsuring reliable data transmission in Network on Chip (NoC) is one of the most challenging tasks, especially in noisy environments. As crosstalk, interference, and radiation were increased with manufacturers' increasing tendency to reduce the area, increase the frequencies, and reduce the voltages. So many Error Control Codes (ECC) were proposed with different error detection and correction capacities and various degrees of complexity. Code with Crosstalk Avoidance and Error Correction (CCAEC) for network-on-chip interconnects uses simple parity check bits as the main technique to get high error correction capacity. Per this work, this coding scheme corrects up to 12 random errors, representing a high correction capac
... Show MoreNew series of metal ions complexes have been prepared from the new ligand [4-Amino-N-(5-methyl-isaxazol-3-yl)-benzenesulfonamide] derived from Sulfamethoxazole and 3-aminophenol. Accordingly, mono-nuclear Mn(II), Fe(III), Co (II), and Rh(III) complexes were prepared by the reaction of previous ligand with MnCl2.4H2O, CoCl2.6H2O, FeCl3.6H2O and RhCl3H2O, respectively. The compounds have been characterized by Fourier-transform infrared (FTIR), ultraviolet–visible (UV–vis), mass, 1H-, and 13C-nuclear magnetic resonance (NMR) spectra and thermo gravimetric analysis (TGA& DSC) curve, Bohr magnetic (B.M.), elemental microanal
... Show MoreThe free Schiff base ligand (HL1) is prepared by being mixed with the co-ligand 1, 10-phenanthroline (L2). The product then is reacted with metal ions: (Cr+3, Fe+3, Co+2, Ni+2, Cu+2 and Cd+2) to get new metal ion complexes. The ligand is prepared and its metal ion complexes are characterized by physic-chemical spectroscopic techniques such as: FT-IR, UV-Vis, spectra, mass spectrometer, molar conductivity, magnetic moment, metal content, chloride content and microanalysis (C.H.N) techniques. The results show the formation of the free Schiff base ligand (HL1). The fragments of the prepared free Schiff base ligand are identified by the mass spectrometer technique. All the analysis of ligand and its metal complexes are in good agreement with th
... Show MoreThis paper investigates a new approach to the rapid control of an upper limb exoskeleton actuator. We used a mathematical model and motion measurements of a human arm to estimate joint torque as a means to control the exoskeleton’s actuator. The proposed arm model is based on a two-pendulum configuration and is used to obtain instantaneous joint torques which are then passed into control law to regulate the actuator torque. Nine subjects volunteered to take part in the experimental protocol, in which inertial measurement units (IMUs) and a digital goniometer were used to measure and estimate the torque profiles. To validate the control law, a Simscape model was developed to simulate the arm model and control law in which measurem
... Show MoreThe researchers wanted to make a novel azo imidazole as a follow-up to their previous work. We focused on the ligand 4-[(2-amino-4-phenylazo)- methyl]-cyclohexane carboxylic acid as a derivative of trans-4- (aminomethyl) cyclohexane carboxylic acid diazonium salt, synthesized a series of its chelate complexes with metal ions, and characterized these compounds using a variety techniques, including elemental analysis, FTIR, LC-Mass, NMR and UV-Vis spectral process as well TGA, conductivity and magnetic quantifications. Analytical data showed that the Cr(III), Mn(II) and Zn(II) complexes out to 1:1 metal-ligand ratio with octahedral geometry except Mn complex has tetrahedral geometry.
New series of metal ions complexes have been prepared from the new ligand [4-Amino-N-(5- methyl-isaxazol-3-yl)-benzenesulfonamide] derived from Sulfamethoxazole and 3-aminophenol. Accordingly, mono-nuclear Mn(II), Fe(III), Co (II), and Rh(III) complexes were prepared by the reaction of previous ligand with MnCl2.4H2O, CoCl2.6H2O, FeCl3.6H2O and RhCl3H2O, respectively. The compounds have been characterized by Fourier-transform infrared (FTIR), ultraviolet–visible (UV–vis), mass, 1H-, and 13C-nuclear magnetic resonance (NMR) spectra and thermo gravimetric analysis (TGA& DSC) curve, Bohr magnetic (B.M.), elemental microanalyses, metal ions, chloride containing, and molar conductance.These reviews uncovered octahedral geometries for complex
... Show MoreIn this work, a comparative analysis for the behavior and pattern of the variations of the IF2 and T Ionospheric indices was conducted for the minimum and maximum years of solar cycles 23 and 24. Also, the correlative relationship between the two ionospheric indices was examined for the seasonal periods spanning from August 1996 to November 2008 for solar cycle 23 and from December 2008 to November 2019 for solar cycle 24. Statistical calculations were performed to compare predicted values with observed values for the selected indices during the tested timeframes. The study's findings revealed that the behavior of the examined indices exhibited almost similar variations throughout the studied timeframe. The seasonal variations were
... Show More