Objective This study evaluated the effects of adding titanium oxide (TiO2) nanofillers on the tear strength, tensile strength, elongation percentage, and hardness of room-temperature-vulcanized (RTV) VST50F and high-temperature-vulcanized (HTV) Cosmesil M511 maxillofacial silicone elastomers. Methods Two types of maxillofacial elastomers, VST50F RTV and Cosmesil M511 HTV, were used. Nano-TiO2 powder was applied as a nanofiller. A total of 120 specimens were fabricated, 60 each of VST50F and Cosmesil M511. The specimens of each type of elastomer were divided into three equal groups on which tests were conducted for tear strength, tensile strength, and hardness i.e., 20 specimens were used for each test. Each group of 20 specimens was further divided into two equal subgroups: (A) control i.e., silicone without nano-TiO2, and (B) experimental i.e., VST50F and Cosmesil M511 silicone incorporated with 0.25 wt% and 0.2 wt% nano-TiO2, respectively. Each subgroup thus had 10 specimens. The specimens were evaluated, and data were studied using descriptive statistical analysis and two-way analysis of variance (ANOVA). Results The addition of 0.25 wt% and 0.2 wt% TiO2 nanofiller into VST50F and Cosmesil M511 elastomers, respectively, resulted in a statistically significant increase in the mean values (p < 0.01) of tear strength, tensile strength, elongation percentage, and hardness of the materials. Conclusion The mechanical properties of the VST50F and Cosmesil M511 maxillofacial silicone materials improved with the addition of select concentrations of nano-TiO2.
Background Doxorubicin (DOX) is a potent antineoplastic agent used in treating various adult and pediatric cancers, but it tends to provoke dose-dependent cardiotoxicity. Ezetimibe (EZE), a cholesterol-lowering drug, has been reported to possess defensive actions against oxidative stress and inflammation, which are two of the main proposed mechanisms underlying the development of DOX-induced cardiotoxicity (DIC), hence, we aimed to inspect the possible protective effect of EZE against DIC in rats. Methods 24 adult male Wistar rats were allocated into four groups of six: control, DOX, 10 mg/kg EZE plus DOX and 20 mg/kg EZE plus DOX. At the end of the study, the experimental rats were anesthetized and blood samples were collected for b
... Show More1-[4-(2-Hydroxy-4, 6-dimethyl-phenylazo)-phenol]-ethanone (HL1) and 2-(4-methoxy-phenylazo)-3, 5-dimethyl-phenol (HL2) were produced by combination the diazonium salts of amines with 3, 5-dimethylphenol. The geometry of azo compounds was resolved on the basis of (C.H.N) analyses, 1H and 13CNMR, FT-IR and UV-Vis spectroscopic mechanisms. Complexes of La (III) and Rh (III) have been performed and depicted. The formation of complexes has been identified by using elemental analysis, FT-IR and UV-Vis spectroscopic process as well, conductivity molar quantifications. Nature of complexes produced have been studied obeyed mole ratio and continuous alteration ways, Beer's law followed through a concentration scope (1×10-4 - 3×10-4 M). H
... Show MoreThe problem of the study was to identify the possibility of benefiting from the application of the target cost system as a modern cost system to activate the environmental cost management instead of the traditional systems used in the company due to the great transformations witnessed by the business environment in all fields, which have resulted in the search for modern systems to provide more accurate and more appropriate information to reduce Costs, because accurate information makes the company have a complete vision to achieve the company’s goals. To solve this problem, the research was based on the following hypothesis (that the role of the target cost system leads to the activation of environmental cost management). Target c
... Show MoreFor the design of a deep foundation, piles are presumed to transfer the axial and lateral loads into the ground. However, the effects of the combined loads are generally ignored in engineering practice since there are uncertainties to the precise definition of soil–pile interactions. Hence, for technical discussions of the soil–pile interactions due to dynamic loads, a three-dimensional finite element model was developed to evaluate the soil pile performance based on the 1 g shaking table test. The static loads consisted of 50% of the allowable vertical pile capacity and 50% of the allowable lateral pile capacity. The dynamic loads were taken from the recorded data of the Kobe e
This study expands the state of the art in studies that assess torsional retrofit of reinforced concrete (RC) multi-cell box girders with carbon fiber reinforced polymer (CFRP) strips. The torsional behavior of non-damaged and pre-damaged RC multi-cell box girder specimens externally retrofitted by CFRP strips was investigated through a series of laboratory experiments. It was found that retrofitting the pre-damaged specimens with CFRP strips increased the ultimate torsional capacity by more than 50% as compared to the un-damaged specimens subjected to equivalent retrofitting. This indicated that the retrofit has been less effective for the girder specimen that did not develop distortion beforehand as a result of pre-loading. From
... Show MoreThe permeability estimates for the uncored wells and a porosity function adopting a modified flow zone index-permeability crossplot are given in this work. The issues with implementing that approach were mostly crossplots, due to the influence of geological heterogeneity, did not show a clear connection (scatter data). Carbonate reservoir flow units may now be identified and characterized using a new approach, which has been formally confirmed. Due to the comparable distribution and flow of clastic and carbonate rock fluids, this zoning method is most effective for reservoirs with significant primary and secondary porosity. The equations and correlations here are more generalizable since they connect these variables by combining cor
... Show MoreMultiple eliminations (de-multiple) are one of seismic processing steps to remove their effects and delineate the correct primary refractors. Using normal move out to flatten primaries is the way to eliminate multiples through transforming these data to frequency-wavenumber domain. The flatten primaries are aligned with zero axis of the frequency-wavenumber domain and any other reflection types (multiples and random noise) are distributed elsewhere. Dip-filter is applied to pass the aligned data and reject others will separate primaries from multiple after transforming the data back from frequency-wavenumber domain to time-distance domain. For that, a suggested name for this technique as normal move out- frequency-wavenumber domain
... Show MoreThe study was carried out to determine the cytotoxic, antioxidant and gastro-protective effect of ethyl-4-[(3,5-di-tert-butyl-2-hydroxybenzylid ene)amino] benzoate (ETHAB) in rats.