A reduced-order extended state observer (RESO) based a continuous sliding mode control (SMC) is proposed in this paper for the tracking problem of high order Brunovsky systems with the existence of external perturbations and system uncertainties. For this purpose, a composite control is constituted by two consecutive steps. First, the reduced-order ESO (RESO) technique is designed to estimate unknown system states and total disturbance without estimating an available state. Second, the continuous SMC law is designed based on the estimations supplied by the RESO estimator in order to govern the nominal system part. More importantly, the robustness performance is well achieved by compensating not only the lumped disturbance, but also its estimation error. Finally, the tracking performance is examined by carrying out several simulations on robotic systems with compliant actuators as an application example of the high order systems. In addition, the comparative study is conducted between the proposed SMC method with RESO and a feedback linearization control (FLC) with a full-order ESO to confirm the estimation and tracking performance of the proposed scheme.
Objective: To identify the role and importance of the clinical pharmacist in the Emergency Department on prevent
or reduced the medication error.
Methodology: We collected the medical file of 3400 patients, 1400 patient's file in (A) hospital, and 1000 patient's
file in each of (B and C) hospital, who admitted to the ED, at primary weekdays between 8 am to 2 pm, and
recorded all the intervention made by clinical pharmacist through an active search in clinical charts, with analysis
of the daily medical prescription. The potential severity of harm of the medication error judged by two reviewers,
a permanent emergency physician, and clinical pharmacist based on the National Coordinating Council (NCC) of
Medication Error
In this paper, an intelligent tracking control system of both single- and double-axis Piezoelectric Micropositioner stage is designed using Genetic Algorithms (GAs) method for the optimal Proportional-Integral-Derivative (PID) controller tuning parameters. The (GA)-based PID control design approach is a methodology to tune a (PID) controller in an optimal control sense with respect to specified objective function. By using the (GA)-based PID control approach, the high-performance trajectory tracking responses of the Piezoelectric Micropositioner stage can be obtained. The (GA) code was built and the simulation results were obtained using MATLAB environment. The Piezoelectric Micropositioner simulation model with th
... Show MoreIn this work, a new development of predictive voltage-tracking control algorithm for Proton Exchange Membrane Fuel Cell (PEMFCs) model, using a neural network technique based on-line auto-tuning intelligent algorithm was proposed. The aim of proposed robust feedback nonlinear neural predictive voltage controller is to find precisely and quickly the optimal hydrogen partial pressure action to control the stack terminal voltage of the (PEMFC) model for N-step ahead prediction. The Chaotic Particle Swarm Optimization (CPSO) implemented as a stable and robust on-line auto-tune algorithm to find the optimal weights for the proposed predictive neural network controller to improve system performance in terms of fast-tracking de
... Show MoreThis paper presents an enhancement technique for tracking and regulating the blood glucose level for diabetic patients using an intelligent auto-tuning Proportional-Integral-Derivative PID controller. The proposed controller aims to generate the best insulin control action responsible for regulating the blood glucose level precisely, accurately, and quickly. The tuning control algorithm used the Dolphin Echolocation Optimization (DEO) algorithm for obtaining the near-optimal PID controller parameters with a proposed time domain specification performance index. The MATLAB simulation results for three different patients showed that the effectiveness and the robustness of the proposed control algorithm in terms of fast gene
... Show MoreThis is a survey study that presents recent researches concerning factional controllers. It presents several types of fractional order controllers, which are extensions to their integer order counterparts. The fractional order PID controller has a dominant importance, so thirty-one paper are presented for this controller. The remaining types of controllers are presented according to the number of papers that handle them; they are fractional order sliding mode controller (nine papers), fuzzy fractional order sliding mode controller (five papers), fractional order lag-lead compensator (three papers), fractional order state feedback controller (three papers), fractional order fuzzy logic controller (three papers). Finally, several conclusions
... Show MoreThe research deals with the structures of the contemporary travelers' buildings in particular, and which is a functional complex installations where flexibility, technical and stereotypes play an important role as well as the human values These facilities must represent physiological and psychological comfort for travelers. TThose are facilities where architectural form plays a distinguished role in reversing the specialty and identity of the building. Hence the importance of the subject has been in forced, as a result for the need to study these facilities and to determine the impact and affects by the surrounding environment, to the extent of the urban, environmental, urban, social, and psychological levels. The importance of the resea
... Show MoreThis work explores the advancement and potential of solar‐powered humidification–dehumidification (HDH) desalination systems, addressing the critical challenge of global water scarcity. Emphasizing solar‐powered humidifiers in HDH systems presents an innovative solution per the urgent demand for sustainable freshwater sources utilizing abundant energy resources. This work reviews various humidifier designs, pointing out their crucial role in the efficiency and yield of HDH desalination units and their operational, maintenance, and scaling issues. Key factors, such as design effectiveness, water‐vapor capacity, and material selection, are assessed to understand their impact on the system's ove