The performance of asphalt pavements is crucial due to heavy traffic loads from civil and industrial developments. Various additives and modifiers are used in flexible roads to improve their resistance to deterioration caused by climatic changes. From this context, modifying the asphalt binder with polymers is popular in asphalt pavement construction. The present research investigates the effect of Polyethylene (PE) polymers in powder form on the characteristics of asphalt mixtures since these polymers are composed of hydrocarbons. It is similar to asphalt binders, making them very effective in enhancing the performance of neat asphalt produced from the oil refinery. To confirm this, two types of PE, High-Density PE (HDPE) and Low-Density PE (LDPE), were blended with neat asphalt binder at different dosages of 0%, 2%, 4%, and 6% by the weight of asphalt binder. The physical tests, including penetration, ductility, softening point, and weight loss on heat, were conducted to examine neat and PE-modified binders' rheological properties, durability, and temperature sensitivity. Marshall stability, stiffness index, tensile strength, and Scanning Electron Microscope (SEM) were also employed to assess the performance of PE-modified asphalt mixtures. The findings reveal that incorporating PE into asphalt mixtures significantly improves their mechanical properties, and the most optimal results are achieved when using 6% of both HDPE and LDPE. Specifically, modifying the asphalt binder with the inclusion of 6% HDPE and LDPE presents a remarkable increase in stability of 167.6% and 150.9%, respectively, compared to conventional mixtures. The stiffness index is improved for HDPE and LDPE-modified mixtures, which offers these mixtures superior resistance to permanent deformation. The moisture damage resistance can be enhanced by modification of the asphalt binder with HDPE and LDPE, especially at the inclusion of 6%. SEM images of asphalt pavement demonstrate HDPE's superiority in terms of distribution and dispersion in asphalt binder. In conclusion, the properties of HDPE-modified mixtures are better than those of LDPE-modified and untreated mixtures.
One of the therapeutic effects of nicotine is used as a protective against developing ulcerative colitis . ulcerative colitis is an inflammatory disease of the bowel affecting the superficial lining mucosa in the rectum and large intestine. In this study nicotine tablets were formulated as modified release tablets targeted to the colon. All formulas were studied for drug release , effect of diluent, retardant concentration, avicel grade,and compression force, the selected formula was then further studied for drug release in 3 different pH ( coated tablets) .The kinetic study revealed acceptable shelf life . Finally the selected formula was given to 6 patients in a pre-liminary clinical study which showed that nicotine c
... Show MoreIn the present study the radon concentration was measured in indoor places by the RAD7 (radon detector) was in some locations at Al-Tuwaitha nuclear site and some surrounding areas for the duration from 13/10/2016 to 2/1/2017 and the measurement of the indoor radon concentration ranged from (4.96±4.4 to 102±25) Bq/m3. The high value of radon has been found at decommissioning directorate /emergency room, which is lower than the action value recommended by the Environmental Protection Agency (EPA) which is (148 Bq/m3) while the lowest value has been founded in central laboratories directorate \ models room. These values were used to calculate the annual effective dose and the health risks for cells bronchial which caused by the inhalatio
... Show MoreUse Almtafr axis to study the response component that isolates gave a positive response to the use of standard Almtafr which leads to lower the temperature and the number of cells at a temperature suitable Rifampicin resistant less than that TJ and similarly reflected on the frequency of mutations induced
This study assessed the quality of hand-dug drinking water sources in Eku and its environs at Eku I, Samagidi, Eku 2, and Okuechi, using the weighted arithmetic water quality index method. Water samples collected from hand-dug wells at these locations returned values for analyzed parameters. Temperature 26 – 30(⁰C), dissolved Oxygen (D.O) 5.2-8mg/l, biological oxygen demand (BOD) 5.2-8(mg/l), Electrical Conductivity (EC) 77-119(µS/cm), Total suspended solids were (TSS) 20000-120000(mg/l), pH 5.31-7.09, Phosphates 2-9.2(mg/l), Alkalinity 28-160(mg/l), Turbidity, 0.02 -0.19(NTU) Total coliform 2 -48 (cfu/ml) and fungal count 1-502. Variations in the values of these parameters were only significant for phosphate, alkalinity, and turb
... Show MoreBackground: The association between diabetes and inflammatory dental diseases had been studied extensively for more than 50 years. A large evidence base suggests that diabetes is associated with an increased prevalence, extent and severity of gingivitis and periodontitis and loss of teeth. Many patients do not aware that they are diabetic.Objectives:The aim of the current study was to assess a fast, non-invasive, safe procedure to screen for diabetes and its severity in dental clinics and to assess the change in blood glucose level before and after tooth extraction during periodontalResults: there were no significant differences between the blood samples collected before tooth extraction from finger puncture method (FPB) and the gingival
... Show MoreBackground: Ejection fraction have been used frequently
for assessment of the left ventricular function, but can be
associated with errors in which myocardial performance
index have been used as another parameter to measure the
left ventricular function.
Objective: selecting another echocardiography parameter
for the assessment of myocardial in function instead of the
ejection fraction.
Methods: 160 patients referred to the echocardiogram unit
from the period december 2007 to august 2008 requesting
assessment of left ventricular function. After clinical
examination, routine blood tests; chest x-ray and
electrocardiographic recording have been completed. All
patients informed to come for this unit af