This research supports the UN’s 2030 Agenda and its goals of ending poverty and hunger. Fruit and vegetable (FandV) lose their freshness and weight when stored at unsuitable temperatures and relative humidity. This study was conducted in Baghdad governorate, located at latitude 33.3128057 and longitude 44.3614875, in the Karrada region from February 27 to April 17, 2024. It compared the effectiveness of different storage technologies, including evaporative cooling, various air velocities, and diverse packaging methods, against sustainable and nonpackaging approaches. The study employed an air cooler with a volume of 2000 ft3/s and insulated packaging. Temperature and relative humidity were recorded in the storage environment every five seconds using an Arduino system equipped with a DHT-22 temperature and humidity sensor. Analysis of the data revealed that evaporative cooling significantly extended eggplant shelf life and reduced weight loss when combined with effective packaging methods. The average SLD of CPS1 was 11 days and the lowest average WL was 3.86% at an average temperature and relative humidity of 16.02° C and 92.9%, respectively. The average SLD of CPS2 was 8 days while that for WL was 7.23% at an average temperature and relative humidity of 21.76° C and 94.08%, respectively. The multiple regression model explained 63% of the data, and the temperature coefficient was lower than for relative humidity, meaning that it is more significant than RH under the conditions of this experiment.

Scopus Crossref
View Publication
Publication Date
Mon Jun 30 2003
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Water Treatment of Cooling Towers Blowdown by Ion Exchange
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Dec 31 2011
Journal Name
Al-khwarizmi Engineering Journal
Effect of Mixed Corrosion Inhibitors in Cooling Water System
...Show More Authors

The effect of mixed corrosion inhibitors in cooling system was evaluated by using carbon steel specimens and weight loss analysis. The carbon steel specimens immersed in mixture of sodium phosphate (Na2 HPO4) used as corrosion inhibitor and sodium glocunate (C6 H11 NaO7) as a scale dispersant at different concentrations (20,40, 60, 80 ppm) and at different temperature (25,50,75 and 100)ºC for (1-5) days. The corrosion inhibitors efficiency was calculated by using uninhibited and inhibited water to give 98.1%. The result of these investigations indicate that the corrosion rate decreases with the increase the corrosion inhibitors concentration at 80 ppm and at 100ºC for 5 days, (i.e,

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Cooling and Heating a Greenhouse in Baghdad by a Solar Assisted Desiccant System
...Show More Authors

Modeling the microclimate of a greenhouse located in Baghdad under its weather conditions to calculate the heating and cooling loads by computer simulation. Solar collectors with a V-corrugated absorber plate and an auxiliary heat source were used as a heating system. A rotary silica gel desiccant dehumidifier, a sensible heat exchanger, and an evaporative cooler were added to the collectors to form an open-cycle solar assisted desiccant cooling system. A dynamic model was adopted to predict the inside air and the soil surface temperatures of the greenhouse. These temperatures are used to predict the greenhouse heating and cooling loads through an energy balance method which takes into account the soil heat gain. This is not included in

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sun Feb 24 2019
Journal Name
Iraqi Journal Of Physics
Construction and performance study of a solar - powered hybrid cooling system in Iraq
...Show More Authors

The systems cooling hybrid solar uses solar collector to convert solar energy into the source of heat for roasting Refrigerant outside of the compressor and this process helps in the transformation of Refrigerant from the gas to a liquid state in two-thirds the top of the condenser instead of two-thirds the bottom of the condenser as in Conventional cooling systems and this in turn reduces the energy necessary to lead the process of cooling. The system cooling hybrid use with a capacity of 1 ton and Refrigerant type R22 and the value of current drawn by the system limits (3.9-4.2A), the same value of electric current calculated by the system are  Conventional  within this atmosphere of Iraq, and after taking different readings

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Annals Of Tropical Medicine And Public Health
The use of eggplant peel powder in the treatment of hyperlipidemia caused by antibiotics administration in male local rabbits
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Plant Archives
The effect of adding nano concentrations of hydrogen peroxide to the diluted semen of iraqi local roosters on some laboratory characteristics after cooling and cryopreservation
...Show More Authors

This study was conducted at the poultry farm located in the College of Agricultural Engineering Sciences, University of Baghdad, Abu Gharib (the old site), and laboratories of the Animal Production Department, Jadriya, to investigate the effect of adding hydrogen peroxide H2O2 at nanoscale levels to semen diluents of local roosters sperm in a number of semen characteristics. In this study, 80 roosters local Iraqi chickens were used, the roosters were trained three times a week, to collect semen, until the largest number of them responded. Then the best 40 of the roosters were elected for the purpose of collecting the semen with a pooled sample, and then the samples were diluted and divided equally into four parts. The concentrations of 0, 1

... Show More
Scopus (3)
Scopus
Publication Date
Mon May 18 2026
Journal Name
Heat Transfer
A Comparative Review of Conventional Mechanical and Solar‐Driven Cooling Technologies: Performance and Environmental Perspectives
...Show More Authors
ABSTRACT<p>Conventional cooling systems are major energy consumers in hot climates, directly contributing to increased carbon emissions and placing a significant strain on Iraq's national electricity grid. This study aims to explore and evaluate clean and sustainable alternatives to conventional systems. The methodology is based on a comparative analysis of various cooling technologies, including mechanical, absorption, adsorption, drying, and hybrid systems, using key performance indicators such as the coefficient of performance (COP), energy consumption, carbon emissions, and system cooling capacity. The results show that innovative solar cooling technologies offer superior operational effi</p> ... Show More
View Publication
Scopus Crossref
Publication Date
Sun Jun 01 2025
Journal Name
Kufa Journal For Agricultural Sciences
Estimating the population density of Vegetable leaf miner Liriomyza sativae Blanchard (Diptera: Agromyzidae) on Tomato and Cucumber crops in the Greenhouses
...Show More Authors

Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
A study of the effect of silica particles addition on some physical properties of PVC as a packaging material
...Show More Authors

In this work, varying compositions of SiO2 micro filler were added
with the Polyvinyl Chloride (PVC) and samples have been prepared
using film casting technique. The results have been analyzed and
compared for PVC samples with (1 wt%, 3 wt%, 5 wt% and 10 wt%)
SiO2 micro filler. Mechanical characteristics such as tensile strength,
elongation at break and Young`s modulus were measured for all the
samples, where the tensile strength was increased from 8.39 Mpa for
purified PVC to 16 Mpa for 3% SiO2/PVC composite. Also, thermal
conductivity measurement values illustrated that composite materials
have a good thermal insulation at 10 wt. %, thermal conductivity was
decreased from 0.1684 W/m.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
EFFECT OF COOLING RATE ON MECHANICAL PROPERTIES OF EUTECTIC AND HYPOEUTECTIC Al-Si ALLOYS
...Show More Authors

In this research the effect of cooling rate and mold type on mechanical properties of the eutectic
and hypoeutectic (Al-Si) alloys has been studied. The alloys used in this research work were (Al- 12.6%Si
alloy) and (Al- 7%Si alloy).The two alloys have been melted and poured in two types of molds with
different cooling rates. One of them was a sand mold and the other was metal mold. Mechanical tests
(hardness, tensile test and impact test) were carried out on the specimens. Also the metallographic
examination was performed.
It has been found that the values of hardness for the alloys(Al-12.6%Si and Al-7%Si) which poured in
metal mold is greater than the values of hardness for the same alloy when it poured in a heated

... Show More
View Publication Preview PDF
Crossref (2)
Crossref