Preferred Language
Articles
/
ThhNdZUBVTCNdQwCrC6T
Determination of Pollutants in Water Treatment for Petroleum Refinery
...Show More Authors

Dora petroleum refinery waste water is the one of the important source of pollution by priority pollutant aromatic compound discharged to Tigris river in Iraq. the station has waste water treatment unit contains many treatment subunits The most important sub units is :skimmer units ,physiochemical unit ,daf unit, biological unit. The aim of research project is to study the ability of unit to remove the priority pollutant aromatic compound and follow up these compounds in river to study ability of river to self removal. A solid phase extraction (SPE) followed by high performance liquid chromatography-ultra violet (HPLC-UV) technique is depicted for the quantitative estimation of benzidines and phenols. Experimental studies were performed to detect the optimum oxidation conditions for benzidine and phenol. The enzymatic method and the use of soybean peroxidase enzyme for the continuous removal of the molecules enable to provide simple and alternative method to the traditional methods used for removal of hazardous aromatic compounds including the phenol and benzidine studied here.

Publication Date
Thu Feb 01 2018
Journal Name
Journal Of Engineering
Upgrading of Alum Preparation and Dosing Unit for Sharq Dijla Water Treatment Plant by Using Programmable Logic Controller System
...Show More Authors

One of the important units in Sharq Dijla Water Treatment Plant (WTP) first and second extensions are the alum solution preparation and dosing unit. The existing operation of this unit accomplished manually starting from unloading the powder alum in the preparation basin and ending by controlling the alum dosage addition through the dosing pumps to the flash mix chambers. Because of the modern trend of monitoring and control the automatic operation of WTPs due to the great benefits that could be gain from optimum equipment operation, reducing the operating costs and human errors. This study deals with how to transform the conventional operation to an automatic monitoring and controlling system depending on a Programmable

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Engineering
Performance Evaluation the Turbidity Removal Efficiency of AL-Muthana Water Treatment Plant
...Show More Authors

Turbidity is a visual property of water that expresses the amount of suspended substances in the water. Its presence in quantities more significant than the permissible limit makes the water undrinkable and reduces the effectiveness of disinfectants in treating pathogens. On this basis, turbidity is used as a basic indicator for measuring water quality. This study aims to evaluate the removal efficiency of AL- Muthanna WTP. Water turbidity was used as a basic parameter in the evaluation, using performance improvement evaluation and data from previous years (2016 to 2020). The average raw water turbidity was 26.7 NTU, with a minimum of 14 NTU, with a maximum of 48 NTU. Water turbidity value for 95% of settling daily readi

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Engineering
Performance Evaluation the Turbidity Removal Efficiency of AL-Muthana Water Treatment Plant
...Show More Authors

Turbidity is a visual property of water that expresses the amount of suspended substances in the water. Its presence in quantities more significant than the permissible limit makes the water undrinkable and reduces the effectiveness of disinfectants in treating pathogens. On this basis, turbidity is used as a basic indicator for measuring water quality. This study aims to evaluate the removal efficiency of AL- Muthanna WTP. Water turbidity was used as a basic parameter in the evaluation, using performance improvement evaluation and data from previous years (2016 to 2020). The average raw water turbidity was 26.7 NTU, with a minimum of 14 NTU, with a maximum of 48 NTU. Water turbidity value for 95% of settling daily reading data was

... Show More
Crossref (5)
Crossref
Publication Date
Mon Dec 20 2021
Journal Name
International Journal Of Human Rights In Healthcare
Organizational health between theory and practice field research in the General Company for Petroleum Products
...Show More Authors
Purpose

This study aims to measure the basic foundations of organizational health in the General Company for Food Products and to indicate the extent of its presence or not within the company under investigation.

Design/methodology/approach

This research was completed using a descriptive and analytical approach using a sample of 97 employees from the General Company for Petroleum Products. Calculating the arithmetic mean, standard deviation, coefficient of variation, and confirmatory factor analysis are all part of the data processing process.

... Show More
View Publication
Scopus (1)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Aug 01 2018
Journal Name
Ecotoxicology And Environmental Safety
Biochemical and molecular alterations in freshwater mollusks as biomarkers for petroleum product, domestic heating oil
...Show More Authors

View Publication
Scopus (6)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Mon Nov 15 2021
Journal Name
Aip Conference Proceedings
Oil skimming followed by coagulation/flocculation processes for oilfield produced water treatment and zero liquid discharge system application
...Show More Authors

The study focused on the treatment of real oilfield produced water from the East Baghdad field affiliated to the Midland Oil Company (Iraq) using an oil skimming process followed by a coagulation/flocculation process for zero liquid discharge system applications. Belt type oil skimmer was utilized for evaluating the process efficiency with various operating conditions such as temperature (17-40 °C) and time (0.5-2.5 hr.). Polyaluminum chloride (PAC) coagulant and polyacrylamide (PAM) flocculant was used to investigate the performance of the coagulation/flocculation process with PAC dosage (5-90 ppm) and pH (5-10) as operating conditions. In the skimming process, the oil content, COD, turbidity, and TSS decreased with an increase in tempera

... Show More
View Publication
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Using Alternative Cogeneration Plants in Iraqi Petroleum Industry
...Show More Authors

The present paper describes and analyses three proposed cogeneration plants include back pressure steam-turbine system, gas turbine system, diesel-engine system, and the present Dura refinery plant. Selected actual operating data are employed for analysis. The same amount of electrical and thermal product outputs is considered for all systems to facilitate comparisons. The theoretical analysis was done according to 1st and 2nd law of thermodynamic. The results demonstrate that exergy analysis is a useful tool in performance analysis of cogeneration systems and permits meaningful comparisons of different cogeneration systems based on their merits, also the result showed that the back pressure steam-turbine is more efficient than other pro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Geotechnical Engineering And Sustainable Construction
Determine the Most Common Geotechnical Risks and Their Impacts on the Cost and Time Schedule for Implementing Water Treatment Plants in Iraq
...Show More Authors

View Publication
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Science Of The Total Environment
Sustainable application of tubular photosynthesis microbial desalination cell for simultaneous desalination of seawater for potable water supply associated with sewage treatment and energy recovery
...Show More Authors

View Publication
Crossref (12)
Crossref
Publication Date
Mon May 08 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Test of the Treatment Unit Efficiency, In Soap and Detergents Factory , In Improving The Quality Of Industrial Waste Water.
...Show More Authors

This study which was carried out from Jan /2010 to Jan/2011,evolution of the efficiency
of treatment unit of al-Ameen factory , a subsidiary of Vegetable Oils General Company in
al- Za
,
faraniya /Sa
,
idea district /South of Baghdad ,via examing the waters coming out of
treatment unit and the role of this unit in improving waters quality , especially in physical and
chemical characteristics to be main factors in studying water's quality, such as temperature
C°,pH,Ec,DO,BOD5,NO3,TDS,PO4
-3
.
The results showed that the characteristics of treated treated water excepte of the Ec
factor were within the acceptable limits,in spite of the high concentration entering the unit .
This confirms t

... Show More
View Publication Preview PDF