ABSTRACT : Diabetes mellitus stands for a set of metabolic diseases that if they are not managed, they can initiate threatening life problems. This study hypothesizes that insulin-like growth factor-1 level can be used as a biomarker for early diagnosing renal problems in patients with type 2 diabetic disease. This study included 30 recently identified type 2 diabetic patients with acute renal malfunction who had an entrance in National Diabetic Center,AL-Mustansiriyah University.They have beenin the Center from October 2018 up to end of April 2019. Their age range has been (40-62) years. Comprehensive clinical investigationhas beencompleted for each patient to discount other diabetic complications like cardiac, neurologic and eye complications.About 30 healthy subjects have beendesignated as a control group that have beencompatible age with patients group. A tester of 10 milliliters venous blood has beenassembledfrom every subject after all nightfasting. Fasting serum glucose, lipid profile, insulin-like growth factor-1 levels were evaluated.Aprofile of serum lipid has exhibited more significant means except for high-density lipoprotein (HDL) cholesterol in diabetic patients with acute renal failure.As compared to the controls, the concentration of insulin-like growth factor-1 was significantly less in diabetic patients with p-value of 0.0001. Also, there has been a significance for negative correlation amid serum insulin-like growth factor-1 level and body mass index, fasting serum glucose, glycated hemoglobin, triacylglycerol, urea, creatinine and leptin while there has been a weighty positive correlation amid serum insulin-like growth factor-1 level and total cholesterol (TG), HDL cholesterol, and low density lipoprotein (LDL) cholesterol in patients group. Early detection for insulin-like growth factor-1 and lipid profile anomalies have roles to minimalize the hazard for expansion of cardiovascular complications for the patients with type 2 diabetic. Insulin-like growth factor-1 levels can be an advantageous indication for categorizing subjects for dangerous cardiovascular disease in the type 2 diabetics
In current article an easy and selective method is proposed for spectrophotometric estimation of metoclopramide (MCP) in pharmaceutical preparations using cloud point extraction (CPE) procedure. The method involved reaction between MCP with 1-Naphthol in alkali conditions using Triton X-114 to form a stable dark purple dye. The Beer’s law limit in the range 0.34-9 μg mL-1 of MCP with r =0.9959 (n=3) after optimization. The relative standard deviation (RSD) and percentage recoveries were 0.89 %, and (96.99–104.11%) respectively. As well, using surfactant cloud point extraction as a method to extract MCP was reinforced the extinction coefficient(ε) to 1.7333×105L/mol.cm in surfactant-rich phase. The small volume of organi
... Show MoreIn this study used three methods such as Williamson-hall, size-strain Plot, and Halder-Wagner to analysis x-ray diffraction lines to determine the crystallite size and the lattice strain of the nickel oxide nanoparticles and then compare the results of these methods with two other methods. The results were calculated for each of these methods to the crystallite size are (0.42554) nm, (1.04462) nm, and (3.60880) nm, and lattice strain are (0.56603), (1.11978), and (0.64606) respectively were compared with the result of Scherrer method (0.29598) nm,(0.34245),and the Modified Scherrer (0.97497). The difference in calculated results Observed for each of these methods in this study.
Aqueous extract of poppy plant) Papaver nudicaule) with five concentrations (50, 100, 150, 200 and 250) mg/l were used to anesthetize fingerlings of the common carp Cyprinus carpio (Mean total length 8.91 ± 0.31 cm and mean total weight 7.72 ± 1.19 gm) instead of the traditional use of MS-222. Results showed that extracted solution of poppy have partial and overall anesthesia effect on these fishes with inverse relationship between the concentrations used and the time needed to reach partial and overall anesthesia, and also direct relationship between concentrations used and time needed for fish recovery. Best results were obtained by using a concentration of 250 mg/l, where time for partial anesthesia was 8 ± 1.52 m
... Show MoreIn this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest deg
... Show MoreZinc Oxide nanoparticles were prepared using pulsed laser ablation process from a pure zinc metal placed inside a liquid environment. The latter is composed of acetyltrimethylammonium bromide (CTAB) of 10−3 molarity and distilled water. A Ti:Sapphire laser of 800 nm wavelength, 1 kHz pulse repetition rate, 130 fs pulse duration is used at three values of pulse energies of 0.05 mJ, 1.11 mJ and 1.15 mJ. The evaluation of the optical properties for the obtained suspension was applied through ultraviolet–visible absorption spectroscopy test (UV/VIS). The result showed peak wavelengths at 210 nm, 211 nm and 213 nm for the three used pulse energies 0.05 mJ, 1.11 mJ and 1.15 mJ respectively. This indicates a blue shift,
... Show MoreIn this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest degradation percent. In additio
... Show More