ABSTRACT: BACKGROUND: The main goal of facelift surgery is to reduce the effect of aging by reposition of face soft tissue in to more youthful orientation. There are many methods for SMAS plication which had different design and vector of pull. AIM OF STUDY: To evaluate the effectiveness and longitivity of 7 shaped SMAS plication in facelift. PATIENT AND METHODS: From January 2020 to march 2021, 10 female patients with age (45-60) years were presented with facial sagging, those patients were subjected to subcutaneous facelift with 7 shaped SMAS plication with fat greft in Al-Shaheed Ghazi Al-Harri Hospital and Baghdad burn medical center at Baghdad medical complex. RESULTS: The average follow up period was 6 to 12 months. The mean operative time was 1 hour and 30 minutes. Additional facial procedures were later done which including: fat injection (all patients), brow lift (one patient), facial scar subcision with fat grafting (one patient) and sub mental liposuction with platysma plication (2 patient). All of our patients demonstrate high level of subjective satisfaction with quick recovery with no major or minor complications CONCLUSION: The subcutaneous facelift with 7 shaped SMAS plication is simple to learn with high patients satisfaction and long lasting result.
Azo-Schiff base compounds (L1 and L2) have been synthesized from the reaction of m-hydroxy benzoic acid with 1,5-dimethyl-3-[2-(5-methyl-1H-indol-3-yl)-ethylimino]-2-phenyl-2,3- dihydro-1H-pyrazol-4-ylamine and with 3-[2-(1H-indol-3-yl)-ethylimino]-1,5-dimethyl-2-phenyl- 2,3-dihydro-1H-pyrazol-4-ylamine. The free ligands and their complexes were characterized based on elemental analysis, determination of metal, molar conductivity, (1H, 13C) NMR, UV–vis, FT-IR, mass spectra and thermal analysis (TGA). The molar conductance data revealed that all the complexes are non-electrolytes. The study of complex formation via molar ratio in DMF solution has been investigated and results were consistent to those found in the solid complexes with a rat
... Show MoreThe effect of UV-light on the tensile properties of pure PC has been studied. It was shown that irradiation of PC undergo a drop in the tensile properties of 30 hour of exposure. The results of irradiated samples shows that the addition of ZnO and TiO2 with different percentages (0.5, 1, 1.5 %) will reduce the Young modulus and ultimate stress of PC/ZnO ,PC/ TiO2 composites
In this research a theoretical study has been carried out on the behavior and strength of simply supported composite beams strengthened by steel cover plate taking into consideration partial interaction of shear connectors and nonlinear behavior of the materials and shear connectors. Following the procedure that already has been adopted by Johnson (1975), the basic differential equations of equilibrium and compatibility were reduced to single differential equation in terms of interface slip between concrete slab and steel beam. Furthermore, in order to consider the nonlinear behavior of steel, concrete and shear connectors, the basic equation was rearranged so that all terms related to materials are isol
... Show MoreBackground: This study aims to investigate the effect of fixed orthodontic appliances and/or antihypertensive drugs on the weight of experimental rats. Materials and Methods: Thir-ty-six male Wistar albino rats were subjected to a split-mouth design study, in which an orthodontic appliance was inserted in one side to move the first molar mesially for 2 weeks while the other side acted as a control to tooth movement. The rats were allocated into three groups: group A (n = 12), without any pharmacological treatment; group B (n = 12), subcu-taneous injection of bisoprolol fumarate (5 mg/kg) daily; and group C (n = 12), subcutaneous injection of valsartan (10 mg/kg) daily. A fixed orthodontic appliance with a closing coil spring delivering 5
... Show MoreWhen the flange of a reinforced concrete spandrel beam is in tension, current design codes and specifications enable a portion of the bonded flexure tension reinforcement to be distributed over an effective flange width. The flexural behavior of the RC L-shaped spandrel beam when reinforcement is laterally displaced in the tension flange is investigated experimentally and numerically in this work. Numerical analysis utilizing the finite element method is performed on discretized flanged beam models validated using experimentally verified L-shaped beam specimens to achieve study objectives. A parametric study was carried out to evaluate the influence of various factors on the beam’s flexure behavior. Results showed that
... Show MoreThis study include design and synthesis of 2 derivatives of compounds consisting of mefenamic acid, glycine and organic nitrates (2-nitrooxy ethanol or 1,3-dinitrooxy-2-propanol). Nitric oxide NO has been reported to support many of the same mucosal protection mechanisms as prostaglandins and is sufficient for acute gastroprotection and ulcer healing. So we suppose these 2 compounds would reduce non-steroidal anti-inflammatory drugs NSAIDs gastrointestinal side effect.
Key words: Non-Steroidal anti-inflammatory dr
... Show MoreIn this study, we set up and analyze a cancer growth model that integrates a chemotherapy drug with the impact of vitamins in boosting and strengthening the immune system. The aim of this study is to determine the minimal amount of treatment required to eliminate cancer, which will help to reduce harm to patients. It is assumed that vitamins come from organic foods and beverages. The chemotherapy drug is added to delay and eliminate tumor cell growth and division. To that end, we suggest the tumor-immune model, composed of the interaction of tumor and immune cells, which is composed of two ordinary differential equations. The model’s fundamental mathematical properties, such as positivity, boundedness, and equilibrium existence, are exami
... Show MoreBackground: Complete denture wearers show lower levels of bite force than dentate subjects. This has a significant influence on their chewing efficiency. In this study an attempt was made to investigate the effect of the impression technique on the maximum bite force in complete denture wearers. Materials and methods: The patients selected for this research were 12 edentulous patients. Three different techniques for registering the final impression were made; the mucostatic, mucofunctional, and the selective pressure impression technique. Two sets of upper and lower denture bases and one set of upper and lower dentures were constructed for each subject. Intraoral and extraoral instruments and devices, as well as a computer program were used
... Show More