Two main grand bus national stations in Baghdad ( Alawi-alhila and Bab-almudam) were chosen as examples to determine lead effect on its drivers. This lead came from ethyl tetra lead or ethyl tri lead which used to improve gasoline quality ,so these two stations could be consider as two of the most polluted places due to gasoline burned by hundreds cars located in these stations .The determination of environmental lead pollution was measured in blood and urines drivers. Drivers were divided in two main groups due to their ages ( 30 persons in each group). The first group for men of 22-30 years old. The second group for men of 40-60 years old. Those men were carefully chosen in order to be non-fumiers or non-alcoholics persons because of
... Show MoreOne of the most significant environmental issues facing the planet today is air pollution. Due to development in industry and population density, air pollution has lately gotten worse. Like many developing nations, Iraq suffers from air pollution, particularly in its urban areas with heavy industry. Our research was carried out in Baghdad's Al-Nahrawan neighbourhood. Recently, ground surveys and remote sensing were used to study the monitoring of air pollution. In order to extract different gaseous and particle data, Earth Data source, Google Earth Engine (GEE), and Geographic Information Systems (GIS) software were all employed. The findings demonstrated that there is a significant positive connection between data collected by ground-ba
... Show MoreAllergic Rhinitis (AR) is a chronic immune system inflammation that occurs when the body overreacts to antigens in the environment (triggers) and produces a variety of symptoms in the nasal mucosa and paranasal sinuses due to the release of many interleukins and cytokines.
We investigated the influence of the allergen on serum levels of TNF-α and Total IgE in patients with AR and their function in initiating allergic rhinitis in Iraqi petrol station workers in Baghdad. One hundred individuals with allergic
... Show MoreThe aim of this work was directed to measure the cosmic ray (CR)
flux and the background (BG) absorbed dose rate for districts of
Baghdad city. The maximum values of CR flux was 2.01
(particle/cm2.s) registered for several Baghdad districts and the
minimum was 0.403 (particle/cm2.s) belonging to Al-kadhimiya
district, whereas the overall average value was 1.24 (particle/cm2.s).
The BG measurements showed that the maximum absorbed dose was
25 nSv/h belonging to Noab AL-Dhbat district and the minimum
absorbed was 19.01 nSv/h observed in Al-Ghadeer district, while
the overall average was 22.56 nSv/h, and this value is small than the
Iraqi permissible limit, which is restricted by Iraqi Center of
Radiation Pr
Air pollution is one of the complex problems plaguing the environment at the present time
as a result of many liberation of gases, vapors and fumes of fuels and chemicals resulting
from industrial activities . It should be noted that there are some elements of the heavy
(Heavy Metals), including toxic in the air, with different concentrations in the air depending
on the nature of the area, for example be in rural areas is lower than in cities or industrial
areas as measured parts million (ppm ) or parts per billion (ppb). Some of these important
elements in the physiological processes and enzymatic organisms but become toxic and
Qatlhand-increase Tercisahaan the permissible limits Bhave nature ,The air contaminant
Air pollution is one of the complex problems plaguing the environment at the present time
as a result of many liberation of gases, vapors and fumes of fuels and chemicals resulting
from industrial activities . It should be noted that there are some elements of the heavy (Heavy
Metals), including toxic in the air, with different concentrations in the air depending on the
nature of the area, for example be in rural areas is lower than in cities or industrial areas as
measured parts million (ppm ) or parts per billion (ppb). Some of these important elements in
the physiological processes and enzymatic organisms but become toxic and Qatlhand-increase
Tercisahaan the permissible limits Bhave nature ,The air contaminant co
Environmental exposures to lead remain a serious problem in the developing and industrializing countries. Children are the highest risk aged-group for lead poisoning. This study was designed to assess lead exposure in Al-Fallujah city by analyzing blood lead levels in children and adults and to explain the relationship between blood lead levels, hematological parameters and ferritin levels in the children. The study was performed on-(90) subjects, (65children and 25 adults).Venous blood samples were taken for estimation of hematological parameters, serum ferritin levels and blood lead levels. The children group was subdivided into four groups as: group (A) (low ferritin, low Hb), group (B) (low ferritin, normal Hb), group (C) (normal fer
... Show MoreThis study has investigated the effect of jaundice on some
hematological and biochemical paramenters in male and female. The results have shown significant decrease in Hemoglobin concentration, packed cell volume, white blood cell count and platelet count. The biochemical parameters results have shown significant increase in prothrombine time, level of total bilirubin, Aspartale transminase and Alanin trans aminase in the serum of male and femal.
The objective of this study is to determine the concentration of copper and lead (mg/L) in drinking water by using absorption spectrophotometic and Atomic Absorption spectrophotometric method from different area in Baghdad and with different intervals , The results show that the concentration of copper and Lead ( mgL) in tap water which remains motionless in plumbing system for following periods one hours, 3 hours, 6 hours, 12 hours, 24 hours, 7 days and 14 days are (1 , 2.2 , 4 , 5.3 , 7.5 , 10 and 16 mgL copper ) & ( 0.3, 0.5 , 0.8 , 1 , 2.5 , 3 , 3.8 mg /L lead ) respectively .from these results its clear that high levels of copper & Lead occur if tap water comes in contact with copper - lead plumbing and copper lead -containing fix
... Show MoreThis study investigates the possibility of using waste plastic as one of the components of expired lead-acid batteries to produce lightweight concrete. Different percentages of lead-acid battery plastic were used in the production of lightweight concrete. The replacements were (70, 80 and 100%) by volume of the fine and coarse aggregate. Results demonstrated that a reduction of approximately 23.6% to 35% in the wet density was observed when replacement of 70% to 100% of the natural aggregate by lead-acid battery plastic. Also, the compressive strength decreased slightly with the increase in plastic content at different curing ages of 7, 28, 60, 90, 120 days. The lowest value of compressive strength was (20.7 MPa) for (wa
... Show More